H1200-1 Aparat do znieczulenia H1200-1 - Anaesthesia Machine | HQS Medical
Aparat do znieczulenia

H1200-1 Aparat do znieczulenia

Model: H1200-1

Wprowadzenie — H1200-1 Aparat do znieczulenia

HQS Vetcare delivers a high-precision veterinary anesthesia equipment system suitable for animal hospitals, pet clinics, and animal laboratories. This anesthesia machine meets the needs of general anesthesia and medical research for various animals, including mice, dogs, cats, rabbits, monkeys, pigs, and sheep.

Najważniejsze funkcje — H1200-1

  • Application 0.5 - 100kg animal
  • Ventilation mode Closed, half - closed, half - open
  • Tidal volume 10 - 2000ml
  • Vaporizer Choose one from Isoflurane, Sevoflurane, Halothane
  • Oxygen source pressure 0.25~0.65Mpa
  • Airway pressure scope -30~60CMH2O
  • Flow Control 0 - 4L/min
  • Oxygen Flush 35L/min~75L/min
  • Pop adjust scope Directs the waste anesthetic gas from the machine to a scavenging system. In the completely open position, the pop - off valve will release pressure at 2 cm H2O, while maintain a constant passive volume in the breathing bags.
  • Inspiration impedance ≦ 0.6Kpa
  • Expiration impedance ≦ 0.6Kpa
  • Absorption tank capacity 700ml
  • Monitoring Airway pressure, Gas source pressure monitoring
  • I:E As doctor need
  • BPM As doctor need
  • Optional V-60V ventilator – Pneumatically driven and electrically controlled
  • Display: LCD digital display
  • Animal Bellow : Big animal : 300 - 1500ML ; Small animal : 0 - 300ML
  • Monitoring : Tidal volume, breathing rate, I:E ratio, p eak airway pressure
  • TV: 20 - 1500ml
  • Breathing rate: 4~60bpm
  • I:E ratio: Adjustable 3:1,2:1,1.5:1,1:1,1:1.5,1:2,1:3
  • Upper airway pressure:2~6kpa
  • Lower airway pressure:0.6~2kpa
  • Build in battery : work time more than 2 hours in case of power failure
  • Alarm: Battery low, Power failure, Airway pressure high/low
  • Alarm Silence : Manuel/Auto Switch
  • PIP scope : 5 - 60 cmH2O
  • Optional V-80V ventilator – Display: 9-inch TFT touch screen
  • Drive gas: Gas type: O2 or Air
  • Inlet pressure: 280 - 600 kPa
  • Max flow : ≤ 120 L/min
  • Operating mode : VCV, PCV, SPONT, Manual, Demo
  • Waveform: Pressure, Flow - rate, Volume Loop: PV loop, PF loop, FV loop
  • Safety pressure: System pressure does not exceed 6 KPa
  • Battery type: Li - ion, work time more than 2 hours
  • Tidal volume: 20 - 1500ml; Increment: 1 ml
  • Respiratory rate: 1 ~ 100 bpm
  • Inspiratory time: 0.1 ~ 10s
  • Respiratory ratio: 9.9:1 to 1:9.9
  • Percentage of inspiratory pause: 0 to 50%
  • PEEP: OFF, 3 ~ 20 cmH2O
  • Pressure Support: 0 ~ 60 cmH2O
  • Pressure Control: 5 ~ 60 cmH2O
  • Flow trigger : 0.5 ~ 20L/min
  • Pressure Trigger Range: - 1 ~ - 20 cmH2O
  • PSV Insp Termination Level : 25%
Cennik e-mailem

Wystarczy podać adres e-mail, a prześlemy ofertę i kartę katalogową tego modelu – zwykle w ciągu jednego dnia roboczego.

Share:

Model-specific documentation

Documents for H1200-1

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

H1200-1 H1200-1 Anesthesia Machine product datasheet

Public PDF

HQS datasheet for the H1200-1: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
H1200-1
Length
3 pages
File
PDF · 314 KB
Web copy prepared
Need a different language or configuration-specific document?

Konfiguracja

  • Main unit, one anesthesia vaporizer, one set veterinary breathing circuit, breathing circuit, gas source hose, exhaust gas absorption system, corrugated connect pipeline, simulated lung.
  • Optional: V-60V or V-80V anesthesia ventilator

Opcje i akcesoria

  • Anesthesia ventilator (V - 60V, V - 80V)
  • trolley
  • non - breathing circuit
  • tracheal intubation
  • anesthesia laryngoscope
  • soda lime
  • active carbon