System do chirurgii laserowej CO2 CL40
Wprowadzenie — System do chirurgii laserowej CO2
The CL40 CO2 Laser Surgery System utilizes microcomputer control with advanced technology for precise laser operations. It features a complete safety system, adjustable pulse width and interval for enhanced flexibility, selectable laser power units, and an adjustable aiming beam for optimal surgical conditions. The system includes automatic obstacle detection and a smoke blow device to protect the lens, making it suitable for various surgical applications in gynaecology, dermatology, ENT, and general surgery.
Najważniejsze funkcje — CL40
- Laser controlled by Microcomputer with advanced technology.
- Complete safety system to ensure maximum safety.
- Adoption of selectable key units of laser power.
- Adjustable aiming beam power to provide with optimum surgical condition.
- There is blow to smoke device can protect the lens.
- Scope of application: gynaecology, dermatology, ENT, general surgery and others: underarm odour, corn, ulcer
System do chirurgii laserowej CO2 Specyfikacja
PARAMETER | SPECIFICATION |
|---|---|
Output Power | 30w |
Display | 8 inch color LCD control display, automatic detection and display fault |
Pulse Width | 0.1 - 2ms |
Pulse recurrence rate | 5 - 500 ms |
Pulse mode | Ultra, continuous, single, repeat pulse |
O utput mode | Continuous /Single / Repeat / Ultra Pulse |
Treatment Size | 20*20mm² (Adjustable) |
Focal Spot Diameter | <0.5mm |
Wavelength | 10600nm |
Cooling system | Water and air cooling |
Articulated arm | 7 joint spring - balanced |
Working radius | 130cm |
Packing | 55*55*123cm, 35/52kg |
Porównanie modeli z tej serii
Różnice podano na podstawie specyfikacji opublikowanych dla poszczególnych modeli. Ostateczną konfigurację prosimy potwierdzić w ofercie.
Ten model należy do serii CL15. Na stronie serii zestawiono wszystkie modele. Przegląd serii
| Parametr | CL15 | CL20 | CL40Ten model | CL50 |
|---|---|---|---|---|
| Output Power | 15w | 15w | 30w | 40 w |
| Display | — | 8 inch color LCD control display | 8 inch color LCD control display, automatic detection and display fault | 8 inch color LCD control display, automatic detection and display fault |
| Pulse mode | Ultra, continuous pulse | Ultra, continuous, single, repeat pulse | Ultra, continuous, single, repeat pulse | Ultra, continuous, single, repeat pulse |
| O utput mode | — | — | Continuous /Single / Repeat / Ultra Pulse | Repeat / Ultra Pulse |
| Cooling system | Air Cooling | water Cooling | Water and air cooling | — |
| Working radius | 110cm | 110cm | 130cm | 140 cm |
| Packing | 88*44*37cm, 15/20kg | 55*32*79cm, 16/21kg | 55*55*123cm, 35/52kg | 55*55*133cm, 40 / 65 kg |
Podobne produkty

Aparat do chirurgii laserem diodowym
Model: HDL10

Aparat do chirurgii laserem diodowym
Model: HDL15A,HDL15B

Terapia chirurgiczna laserem diodowym
Model: HDL-PR0

System do chirurgii laserowej CO2
Model: CL15