Monitor wieloparametrowy HM-500V - Multiparameter Monitor | HQS Medical
Monitor wieloparametrowy

Monitor wieloparametrowy HM-500V

Model: HM-500V

Wprowadzenie — Monitor wieloparametrowy

The HM - 500V is a 12.1-inch TFT LCD multiparameter monitor designed for comprehensive patient monitoring. It features multiple display modes, a 3-level visual and audible alarm system, and the capability to connect with a central monitoring system for remote and wireless monitoring. Its wide-angle alarm indicator enhances patient safety, complemented by an advanced patient information management system.

Najważniejsze funkcje — HM-500V

  • 12.1 inch TFT LCD display
  • Multiple display modes
  • 3 - level visual and audible alarm
  • Connect with central monitoring system for remote and wireless monitor
  • Wide - angle alarms indicator makes patient safer
  • Advance patient information managements system
Cennik e-mailem

Wystarczy podać adres e-mail, a prześlemy ofertę i kartę katalogową tego modelu – zwykle w ciągu jednego dnia roboczego.

Share:

Model-specific documentation

Documents for HM-500V

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

HM-500V Multiparameter Monitor product datasheet

Public PDF

HQS datasheet for the HM-500V: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
HM-500V
Length
3 pages
File
PDF · 239 KB
Web copy prepared
Need a different language or configuration-specific document?

Monitor wieloparametrowy Specyfikacja

Specification
Parameter
Value
ECG Lead mode
-
5 lead,RA,LA,RL,LL,V
Lead selection
-
I,II, III,V, AVF,AVL,AVR
ECG waveform
-
1 or 3 channels
Gain selection
-
×1/4, ×1/2, ×1, ×2, ×4, auto
Sweep speed
-
6.25mm/s,12.5mm/s,25mm/s,50mm/s
Heart rate range
-
25 - 350BPM
Accuracy
-
± 2BPM or ± 2% (whichever is greater)
Resolution
-
1BPM
S - T deletion
-
Yes
NIBP Method
-
Oscillometric with step - down deflation
Range of systolic
-
40 to 270mmHg
Range of mean arterial
-
30 to 220mmHg
Range of diastolic
-
20 to 200mmHg
Measurement time
-
30 to 50 seconds typical , 180 seconds maximum
Alarm range
-
20 - 260 (in 1mmHg steps), and OFF
Temperature Channel
-
Two
Measuring range
-
0 - 50° C
Accuracy
-
± 0.2° C, plus the temperature sensor tolerance
Resolution
-
0.1° C
SPO2 Range
-
0 - 100%
Accuracy
-
± 2 at 70 - 100%
Resolution
-
1%
Range of pulse rate
-
25 - 350BPM
Resolution
-
1BPM
Respiration Measurement range
-
0 - 130rpm
Accuracy
-
± 1rpm
Resolution
-
1rpm
CO2 (Optional) Range
-
0 - 150mmHg
Accuracy
-
0-40 mmHg: ± 2 mmHg; 41-150 mmHg: ± 10% of reading
Range of Respiration
-
2 - 150rpm
Accuracy
-
± 1%rpm
Preheating time
-
10s
Power AC input
-
100 to 240v, 50/60Hz
Environmental Temperature (Storage)
-
- 40 to 75° C
Environmental Temperature (Operating)
-
0 to 50° C
Humidity (Operating)
-
15 to 95%
Humidity (Storage)
-
10 to 95%
Battery Full charging time
-
3 hours
Operating time
-
approx. 4.5 hours
Power consumption
-
80VA
Depth
-
183 mm (7.20 inches)
Width
-
324 mm ( 12.76 inches)
Height
-
324 mm ( 12.76 inches)
Weight
-
3.75 kg (8.27 lbs)

Konfiguracja

  • ECG/Resp/Temp/SpO2/NIBP/Lithium battery/Power Cord

Opcje i akcesoria

  • ETCO2/Recorder/Trolley/Brace/central station software

Gwarancja i serwis posprzedażowy dla HM-500V

Jak HQS obsługuje gwarancję, części zamienne i naprawy tego modelu.

Okres gwarancji
Gwarancja na jednostkę główną zależy od modelu i zamówienia. Obowiązujący okres jest podany w ofercie i potwierdzeniu zamówienia; prosimy sprawdzić go przed zakupem.
Zakres
Usterka spowodowana wadą produkcyjną lub jakościową w okresie gwarancji jest naprawiana bezpłatnie. Materiały eksploatacyjne i akcesoria, uszkodzenia wynikające z niewłaściwego użytkowania oraz urządzenia ze zmienioną lub usuniętą etykietą numeru seryjnego nie są objęte gwarancją na jednostkę główną.
Części zamienne
Części zamienne i wsparcie techniczne są dostępne przez co najmniej osiem lat od daty wysyłki przez HQS.
Czas odpowiedzi
Zgłoszenia serwisowe otrzymują pierwszą odpowiedź w ciągu jednego dnia roboczego. Prosimy podać numer seryjny, model, wersję jednostki głównej i opis problemu.
Naprawy gwarancyjne
Jeśli potwierdzona usterka gwarancyjna wymaga części zamiennej, HQS wysyła ją na własny koszt, a uszkodzona część jest odsyłana do HQS.
Naprawy pogwarancyjne
HQS najpierw przesyła wycenę według kosztów i fakturę pro forma. Naprawione części są testowane przed odesłaniem. Pomoc techniczna przez e-mail lub telefon jest bezpłatna.