| Water Output Type | RO water outlet*1 and DI water outlet*1 / RO water outlet*1 and DI water outlet*1 | RO Water / RO Water | RO and DI Water / RO and DI Water | R O water / RO water / RO water / RO water | RO and DI water / RO and DI water / RO and DI water / RO and DI water |
|---|
| Water Output Speed | 10 L/H / 15 L/H | 15L/H / 30L/H | 15L/H / 30L/H | 45L/H / 63L/H / 94L/H / 125L/H | 45L/H / 63L/H / 94L/H / 125L/H |
|---|
| Purifying Procedure | PF+AC+RO+DI / PF+AC+RO+DI | PF+AC+RO+ AC / PF+AC+RO+ AC | PF+AC+RO+DI / PF+AC+RO+DI | — | — |
|---|
| Water Supply Requirement | When working, the inlet water pressure is 0.1 - 0.3Mpa, and the water quality meets the requirements of GB5749,15 - 35 ° C / When working, the inlet water pressure is 0.1 - 0.3Mpa, and the water quality meets the requirements of GB5749,15 - 35 ° C | Tap water:TDS<200 ppm,5~45° C,1.0 - 4.0kg/c / Tap water:TDS<200 ppm,5~45° C,1.0 - 4.0kg/c | Tap water:TDS<200 ppm,5~45° C,1.0 - 4.0kgf/cm2 (If inlet TDS > 200 ppm ,extra pretreatment filter is recommended) / Tap water:TDS<200 ppm,5~45° C,1.0 - 4.0kgf/cm2 (If inlet TDS > 200 ppm ,extra pretreatment filter is recommended) | T ap water: TDS 200ppm, extra pretreatment filter is recommended) / T ap water: TDS 200ppm, extra pretreatment filter is recommended) / T ap water: TDS 200ppm, extra pretreatment filter is recommended) / T ap water: TDS 200ppm, extra pretreatment filter is recommended) | Tap water: TDS 200ppm, extra pretreatment filter is recommended) / Tap water: TDS 200ppm, extra pretreatment filter is recommended) / Tap water: TDS 200ppm, extra pretreatment filter is recommended) / Tap water: TDS 200ppm, extra pretreatment filter is recommended) |
|---|
| Purification system | 10’’PP filter×1+10’’Activated carbon ×2 / 10’’PP filter×1+10’’Activated carbon ×2 | — | Pretreatment unit PP filter× 1, Special spun fiber filter× 25um PP deep filter Special active carbon filter× 2 RO unit 100GPD RO membrane× 1 Subsequent unit Deionization purification column (Imported resin) × 2 / Pretreatment unit PP filter× 1, Special spun fiber filter× 25um PP deep filter Special active carbon filter× 2 RO unit 200GPD RO membrane× 1 Subsequent unit Deionization purification column (Imported resin) × 3 | — | — |
|---|
| Flow rate | 167 ml/min / 250ml/min | 2 Liters/min (with pressure tank) / 2 Liters/min (with pressure tank) | 2.0 Liters/min ( when there is water in the water tank) / 2.0 Liters/min ( when there is water in the water tank) | — | — |
|---|
| Water Quality Monitor | — | — | TDS/conductivity test pen / TDS/conductivity test pen | TDS/conductivity test pen / TDS/conductivity test pen / TDS/conductivity test pen / TDS/conductivity test pen | — |
|---|
| Consumption | 46W / 46W | — | 72W / 72W | 120W / 240W / 240W / 240W | 120W / 240W / 240W / 240W |
|---|
| Power supply | AC220 V± 10%,50Hz ± 10% / AC220 V± 10%,50Hz ± 10% | AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) | AC220V,50/60Hz(Standard) / AC220V,50/60Hz(Standard) | AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) | AC220V, 50/60Hz(Standard) / AC220V, 50/60Hz(Standard) / AC220V, 50/60Hz(Standard) / AC220V, 50/60Hz(Standard) |
|---|
| External Size (H× W× D) | — | 410*220*420mm / 410*220*420mm | 410*220*420mm / 410*220*420mm | 640*540*1110mm / 640*540*1110mm / 640*540*1110mm / 640*540*1110mm | 640*540*1110mm / 640*540*1110mm / 640*540*1110mm / 640*540*1110mm |
|---|
| Package size (H× W× D) | — | 600*490*580mm / 600*490*580mm | 600*490*580mm / 600*490*580mm | 650*750*1280mm / 650*750*1280mm / 650*750*1280mm / 650*750*1280mm | 650*750*1280mm / 650*750*1280mm / 650*750*1280mm / 650*750*1280mm |
|---|
| Purification system Pretreatment unit | — | PP filter× 1 + PP cotton filter× 1 / PP filter× 1 + PP cotton filter× 1 | — | 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 | 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 |
|---|
| RO unit | — | 100GPD RO membrane× 1 / 200GPD RO membrane× 1 | — | 300 GPD RO membrane× 1 / 400 GPD RO membrane× 1 / 600 GPD RO membrane× 1 / 400 GPD RO membrane× 2 | 300 GPD RO membrane× 1 / 400 GPD RO membrane× 1 / 600 GPD RO membrane× 1 / 400 GPD RO membrane× 2 |
|---|
| Pure water quality Ion rejection rate | — | 97%~99% (New RO membrane) / 97%~99% (New RO membrane) | — | 97%~99% (New RO membrane) / 97%~99% (New RO membrane) / 97%~99% (New RO membrane) / 97%~99% (New RO membrane) | — |
|---|
| Organic rejection rate | — | 99%,when MW > 200 Dalton / 99%,when MW > 200 Dalton | — | > 99%,when MW > 200 Dalton / > 99%,when MW > 200 Dalton / > 99%,when MW > 200 Dalton / > 99%,when MW > 200 Dalton | — |
|---|
| Bacteria | — | <0.1cfu (with optional 0.45+0.1 μ m PES terminal filter) / <0.1cfu (with optional 0.45+0.1 μ m PES terminal filter) | — | <0.01cfu/ml (with optional 0.2 μ m PES terminal filter) / <0.01cfu/ml (with optional 0.2 μ m PES terminal filter) / <0.01cfu/ml (with optional 0.2 μ m PES terminal filter) / <0.01cfu/ml (with optional 0.2 μ m PES terminal filter) | — |
|---|