Niskotemperaturowy sterylizator plazmowy H2O2 HO-D100,D130,D220 - H2O2 Low-Temp Plasma | HQS Medical
Plazma niskotemperaturowa H2O2

Niskotemperaturowy sterylizator plazmowy H2O2 HO-D100,D130,D220

Model: HO-D100,D130,D220

Wprowadzenie — Niskotemperaturowy sterylizator plazmowy H2O2

The HO-D series H2O2 Low Temperature Plasma Sterilizer offers advanced sterilization solutions for medical equipment. Featuring automatic door vertical operation and electric heating, these units provide efficient and reliable sterilization cycles. With multiple volume options and a user-friendly LCD touch screen interface, the sterilizers ensure safe and effective processing of sensitive instruments.

Najważniejsze funkcje — HO-D100,D130,D220

  • 7-inch color touch screen display
  • Displays temperature, pressure, time, cycle mode, process stage, and alarm information
  • Microcomputer-controlled biological indicator dedicated constant temperature incubator with temperature control accuracy of ≤ ± 0.3 ° C
  • Two programs: strengthen circulation and rapid circulation
  • Uses vacuum pumps from well-known domestic manufacturers
  • Self-priming injection type for hydrogen peroxide filling
  • Over-voltage and over-temperature protection functions
  • Door anti-pinch function with door barrier switch
Cennik e-mailem

Wystarczy podać adres e-mail, a prześlemy ofertę i kartę katalogową tego modelu – zwykle w ciągu jednego dnia roboczego.

Share:

Model-specific documentation

Documents for HO-D100,D130,D220

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

HO-D100,D130,D220 H2O2 Low Temperature Plasma Sterilizer product datasheet

Public PDF

HQS datasheet for the HO-D100,D130,D220: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
HO-D100,D130,D220
Length
2 pages
File
PDF · 292 KB
Web copy prepared
Need a different language or configuration-specific document?

Niskotemperaturowy sterylizator plazmowy H2O2 Specyfikacja

PARAMETER
SPECIFICATION
Product name
Low temperature hydrogen peroxide plasma sterilizer
Product form
Automatic door vertical
Heating method
Electric heating
Power
Volume
Chamber size
HO - D100
3.4KVA / 100L
(Liner size: 700 ×430 ×360mm)
HO - D130
3.5KVA / 135L
(Liner size: 750 ×450 ×400mm)
HO - D220
4.3KVA / 190L
(Liner size: 820 ×510×460mm)
Power
AC220V, 50Hz
Installation environment
10 - 50 ℃
Sterilization temperature
50± 5 ℃
Select sterilizing agent
58% - 60% concentration of hydrogen peroxide (H202)
Sterilization time
35 - 50 minutes
Vacuum speed
Pumped to 50pa in 5 minutes
Temperature display
LCD touch screen
Maximum anti - stress value
10p a
Operation height
≤160cm
Material of Sterilization Chamber
The cavity structure is rectangular.
Outer box material
ABS plastic
Electrode mesh material
aluminum alloy material 5052, sheet metal forming, thickness ≥ 2mm.
Seal door material
Use high - quality 5052 aluminum material, thickness ≥15mm.
Loading method
Two layers of upper and lower aluminum alloy punching plates are loaded with sterilized items.
Door opening method
Adopt jack - driven electric lift door.
Door anti - pinch function
Has the func tion of door barrier switch.
Cavity temperature heating power
-
Preheating heating time
≤30min.
Main insulation
≥20mm rubber and plastic sponge.
Full automatic control system
LCD circuit touch screen display PLC circuit design, safe and reliable.
Printer
A micro - printer is used to print out the data every minute during the entire sterilization process, which can be permanently saved.
PLC
Use Siemens smart series PLC control system.
Display screen
A 7 - inch color touch screen is used, and the communication rate is ≥ 9600bps.
Display status
Temperature, pressure, time, cycle mode, process stage and alarm information, etc.
Storage function
Able to store and record 500 sterilization data
Biological indicator incubator
A microcomputer-controlled biological indicator dedicated constant temperature incubator with a temperature control accuracy of ≤ ± 0.3 ° C within the full range.
Pressure Sensor
The built - in pressure sensor uses imported sensors.
Temperature Sensor
Built - in temperature sensor automatically detects the temperature in the cavity.
Program system
There are two programs to strengthen circulation and rapid circulation.
Vacuum system
The vacuum pumps of well - known domestic manufacturers are used.
Evacuation Control Valve
Adopt high vacuum baffle solenoid valve to control the evacuation pipeline.
Oil mist filter
The product has an exhaust oil mist filter system.
Air filter
The filtration accuracy is less than or equal to 0.22 μ m.
Plasma power supply
Transistor controlled power supply, power ≤800W.
Hydrogen peroxide filling method
Self - priming injection type.
Sterilization effect
A silicone hose with an inner diameter of 1mm and a length of 4 meters can achieve the sterilizat ion effect.
Heating System
Adopt explosion - proof flame retardant heating system.
Various protection functions
With over - voltage and over - temperature protection functions.

Porównanie modeli z tej serii

Różnice podano na podstawie specyfikacji opublikowanych dla poszczególnych modeli. Ostateczną konfigurację prosimy potwierdzić w ofercie.

Ten model należy do serii HO-DZ100,DZ130,DZ220. Na stronie serii zestawiono wszystkie modele. Przegląd serii

ParametrHO-D60HO-D100,D130,D220Ten modelHO-DZ100,DZ130,DZ220
Product nameLow temperature plasma hydrogen peroxide sterilizerLow temperature hydrogen peroxide plasma sterilizerLow temperature plasma hydrogen peroxide sterilizer
Product formManual door verticalAutomatic door verticalAutomatic door vertical
Power2.6KWVolume / Chamber sizeAC220V, 50Hz
Installation environment—10 - 50 ℃10 - 40 ℃
Select sterilizing agentHydrogen peroxide (H202)58% - 60% concentration of hydrogen peroxide (H202)—
Sterilization time35 - 50min35 - 50 minutes35 - 55 minutes
Operation height≤140cm≤160cm≤160cm
Material of Sterilization ChamberThe cavity structure is rectangular, which improves the space utilization rate; the cavity material is 5052 high - quality aluminum material, and the cavity thickness is ≥ 8mm.The cavity structure is rectangular.—
Outer box materialABS plasticABS plasticABS plastic disposable plastic.
Electrode mesh materialaluminum alloy material 5052, sheet metal forming, thickness ≥ 2mmaluminum alloy material 5052, sheet metal forming, thickness ≥ 2mm.aluminum alloy material 5052, sheet metal forming, thickness ≥ 2mm.
Loading methodThe upper and lower two layers of aluminum alloy punching plates are loaded with sterilized items, with large loading capacity and high space utilization rate.Two layers of upper and lower aluminum alloy punching plates are loaded with sterilized items.—
Door opening methodManual right sliding doorAdopt jack - driven electric lift door.—
Preheating heating time≤30min≤30min.≤30min.
Full automatic control systemLCD circuit touch scre en display PLC circuit design, safe and reliable.LCD circuit touch screen display PLC circuit design, safe and reliable.LCD circuit touch screen display PLC circuit design, safe and reliable, the system can be maintained and upgraded.
Display screenA 7 - i nch color touch screen is used, and the communication rate is ≥ 19.2Kbps.A 7 - inch color touch screen is used, and the communication rate is ≥ 9600bps.A 7 - inch color touch screen is used, and the communication rate is ≥ 19.2Kbps.
Display statusTemperature, pressure, time, cycle mode, process stage and alarm information, etc.Temperature, pressure, time, cycle mode, process stage and alarm information, etc.Temperature, pressure, time, cycle mode, process stage and alarm information, etc., and provide actual interface photos.

Konfiguracja

  • Two layers of upper and lower aluminum alloy punching plates for loading sterilized items
  • Jack-driven electric lift door