Przenośny ciśnieniowy sterylizator parowy YX-280DM - Portable Type | HQS Medical
Przenośny

Przenośny ciśnieniowy sterylizator parowy YX-280DM

Model: YX-280DM

Wprowadzenie — Przenośny ciśnieniowy sterylizator parowy

The YX-280D M is a portable pressure steam sterilizer designed with a full SUS 304 stainless steel structure for durability. It features an accurate double scale indication pressure gauge, silicone seal for leak-proof operation, and LED digital display for sterilization temperature and time. Both temperature and time are adjustable, and the unit includes automatic release for overpressure and automatic power-off for water shortage.

Najważniejsze funkcje — YX-280DM

  • Full SUS 304 stainless steel structure
  • Accurate double scale indication pressure gauge
  • Silicone seal ensuring no steam leakage
  • LED digital display temperature and time of sterilization
  • Temperature and time of sterilization can be set
  • Automatic release when overpressure
Cennik e-mailem

Wystarczy podać adres e-mail, a prześlemy ofertę i kartę katalogową tego modelu – zwykle w ciągu jednego dnia roboczego.

Share:

Model-specific documentation

Documents for YX-280DM

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

YX-280DM Portable Pressure Steam Sterilizer product datasheet

Public PDF

HQS datasheet for the YX-280DM: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
YX-280DM
Length
1 pages
File
PDF · 234 KB
Web copy prepared
Need a different language or configuration-specific document?

Przenośny ciśnieniowy sterylizator parowy Specyfikacja

Model
YX - 280D M (18L)
YX - 280D M (24L)
YX - 280D M (30L)
Volume
18L
24L
30L
Max Working Temperature
129 ℃
129 ℃
129 ℃
Max Working Pressure
0.165Mpa
0.165Mpa
0.165Mpa
Time Range
0 - 999min
0 - 999min
0 - 999min
Temperature Range
RT - 129 ℃
RT - 129 ℃
RT - 129 ℃
Sterilization Chamber
Φ 300*330mm
Φ 300*460mm
Φ 300*520mm
Power
AC220V/50Hz/2.0K W
AC220V/50Hz/2.0K W
AC220V/50Hz/2.0K W

Porównanie modeli z tej serii

Różnice podano na podstawie specyfikacji opublikowanych dla poszczególnych modeli. Ostateczną konfigurację prosimy potwierdzić w ofercie.

Ten model należy do serii YX-280A. Na stronie serii zestawiono wszystkie modele. Przegląd serii

ParametrYX-280AYX-280BYX-280DYX-280DMTen model
Time Range——0 - 80min / 0 - 80min / 0 - 80min0 - 999min / 0 - 999min / 0 - 999min
Temperature Range——115 ℃ - 129 ℃ / 115 ℃ - 129 ℃ / 115 ℃ - 129 ℃RT - 129 ℃ / RT - 129 ℃ / RT - 129 ℃