Cyfrowy pionowy ciśnieniowy sterylizator parowy LX-D - Vertical Type | HQS Medical
Pionowy

Cyfrowy pionowy ciśnieniowy sterylizator parowy LX-D

Model: LX-D

Wprowadzenie — Cyfrowy pionowy ciśnieniowy sterylizator parowy

The LX-D Digital Vertical Pressure Steam Sterilizer offers a robust and reliable solution for sterilization needs. Constructed with full SUS 304 stainless steel, it features a double-scale indication pressure gauge, a silicone seal for leak-proof operation, and user-settable sterilization temperature and time. Safety is enhanced with an emergency stop switch and automatic release for overpressure, along with automatic power-off in case of water shortage. An optional drying function is available, and the unit is controlled by PID microcomputer with LED digital display for temperature and time.

Najważniejsze funkcje — LX-D

  • Full SUS 304 stainless steel structure
  • Accurate double scale indication pressure gauge
  • Silicone seal ensuring no steam leakage
  • Temperature and time of sterilization can be set
  • Emergency stop switch
  • Automatic release when overpressure
  • Drying function can be added
  • PID Microcomputer Control, LED digital display temperature and time
Cennik e-mailem

Wystarczy podać adres e-mail, a prześlemy ofertę i kartę katalogową tego modelu – zwykle w ciągu jednego dnia roboczego.

Share:

Model-specific documentation

Documents for LX-D

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

LX-D Digital Vertical Pressure Steam Sterilizer product datasheet

Public PDF

HQS datasheet for the LX-D: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
LX-D
Length
1 pages
File
PDF · 207 KB
Web copy prepared
Need a different language or configuration-specific document?

Cyfrowy pionowy ciśnieniowy sterylizator parowy Specyfikacja

Model
LX - D 35L (Digital)
LX - D 50L (Digital)
LX - D 75L (Digital)
LX - D 100L (Digital)
LX - D 120L (Digital)
LX - D 150L (Digital)
Volume
35L
50L
75L
100L
120L
150L
Max Working Temperature
134 ℃
134 ℃
134 ℃
134 ℃
134 ℃
134 ℃
Max Working Pressure
0.22Mpa
0.22Mpa
0.22Mpa
0.22Mpa
0.22Mpa
0.22Mpa
Time Range
0 - 999min
0 - 999min
0 - 999min
0 - 999min
0 - 999min
0 - 999min
Temperature Range
RT - 134 ℃
RT - 134 ℃
RT - 134 ℃
RT - 134 ℃
RT - 134 ℃
RT - 134 ℃
Sterilization Chamber
Φ 320*485 mm
Φ 320*545 mm
Φ 388*480 mm
Φ 388*630 mm
Φ 460*590 mm
Φ 460*700 mm
Power
AC220V/50 Hz/2.5KW
AC220V/50 Hz/2.5KW
AC220V/50 Hz/3.5KW
AC220V/50 Hz/4.0KW
AC220V/50 Hz/4.0KW
AC220V/50 Hz/4.0KW

Opcje i akcesoria

  • Drying function