Negatoskop do zdjęć RTG XPI/X-PII/X-PIII/X-PIV - X-ray Film Illuminator | HQS Medical
Negatoskop

Negatoskop do zdjęć RTG XPI/X-PII/X-PIII/X-PIV

Model: XPI/X-PII/X-PIII/X-PIV

Wprowadzenie — Negatoskop do zdjęć RTG

This X-ray Film Illuminator features an imported acrylic transparent board (2.5 cm thickness) with plug-and-play functionality. The screen automatically turns on when an X-ray film is inserted and can be set to delay shutdown, with options for environmental protection and fatigue reduction. It offers a huge range of light adjustment (300-4000 cd/m²) to meet diverse diagnostic needs and utilizes advanced LED technology with a service life of up to 100,000 hours, ensuring no dark areas during film viewing.

Najważniejsze funkcje — XPI/X-PII/X-PIII/X-PIV

  • Plug and play function, screen will turn on automatically when X-ray film is inserted.
  • Screen can be delayed to shut down (7 gears, 0.5 to 10 minutes).
  • Huge range of light adjustment function (less than 300 and bigger than 4000 cd/m²), which fully meet the requirements for reading and diagnosis of different X-ray films.
  • Adopts advanced LED with life service time up to 100,000 hours.
  • No dark area during watching X-ray film.
Cennik e-mailem

Wystarczy podać adres e-mail, a prześlemy ofertę i kartę katalogową tego modelu – zwykle w ciągu jednego dnia roboczego.

Share:

Negatoskop do zdjęć RTG Specyfikacja

Item
XPI LED
XPII LED
XPIII LED
XPIIII LED
Outer size
531*498*25 mm
912*498*25 mm
1273*498*25 mm
1654*498*25 mm
Size of reading area
363*426 mm
744*426 mm
1105*426 mm
1486*426 mm
Light source
LED illumination (Up to 100,000 hours service life)
LED illumination (Up to 100,000 hours service life)
LED illumination (Up to 100,000 hours service life)
LED illumination (Up to 100,000 hours service life)
Color temperature
9500 k
9500 k
9500 k
9500 k
Power
AC 90~240 V, 50~60 Hz
AC 90~240 V, 50~60 Hz
AC 90~240 V, 50~60 Hz
AC 90~240 V, 50~60 Hz
Average lightness
Fixed lightness: no less than 2000cd/m²
Fixed lightness: no less than 2000cd/m²
Fixed lightness: no less than 2000cd/m²
Fixed lightness: no less than 2000cd/m²
Adjustable lightness
Lowest lightness is no more than 300 cd/m² Highest lightness is no less than 4000 cd/m²
Lowest lightness is no more than 300 cd/m² Highest lightness is no less than 4000 cd/m²
Lowest lightness is no more than 300 cd/m² Highest lightness is no less than 4000 cd/m²
Lowest lightness is no more than 300 cd/m² Highest lightness is no less than 4000 cd/m²
Uniformity of lightness
No less than 90%
No less than 90%
No less than 90%
No less than 90%
Installation method
Wall-mounted, and mobile (Support is optional, needed to buy separately)
Wall-mounted, and mobile (Support is optional, needed to buy separately)
Wall-mounted, and mobile (Support is optional, needed to buy separately)
Wall-mounted, and mobile (Support is optional, needed to buy separately)
Ambient condition
Ambient illuminance in X-ray film reading room should be no more than 100 Lx
Ambient illuminance in X-ray film reading room should be no more than 100 Lx
Ambient illuminance in X-ray film reading room should be no more than 100 Lx
Ambient illuminance in X-ray film reading room should be no more than 100 Lx

Konfiguracja

  • Wall-mounted installation
  • Mobile installation

Opcje i akcesoria

  • Support is optional, needed to buy separately