The HWP-III Water Purifier is designed to provide high-purity water for laboratory and medical applications. It features a multi-stage purification system including RO and DI, ensuring excellent water quality with high ion rejection rates and resistivity. The system is equipped with automatic control and monitoring functions for convenient and reliable operation.

Temel Özellikler — HWP-III

  • Automatic electronic pressure sensor controlling
  • RO membrane auto flushing
  • Automatic stop when water supply shortage
  • Automatic stop when water tank full
  • Automatic cutting off water when pump stop
  • 24 hours non-stop work
Fiyat listesini e-postayla alın

E-posta adresinizi bırakın; bu modelin teklifini ve teknik veri sayfasını genellikle bir iş günü içinde gönderelim.

Share:

Model-specific documentation

Documents for HWP-III

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

HWP-III Water Purifier product datasheet

Public PDF

HQS datasheet for the HWP-III: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
HWP-III
Length
2 pages
File
PDF · 204 KB
Web copy prepared
Need a different language or configuration-specific document?

Su Arıtma Cihazı Teknik Özellikler

MODEL
HWP-III 15
HWP-III 30
Display
LCD
LCD
Water Output Type
RO and DI Water
RO and DI Water
Water Output Speed
15L/H
30L/H
Purifying Procedure
PF+AC+RO+DI
PF+AC+RO+DI
Water Supply Requirement
Tap water:TDS<200 ppm,5~45° C,1.0 - 4.0kgf/cm2 (If inlet TDS > 200 ppm ,extra pretreatment filter is recommended)
Tap water:TDS<200 ppm,5~45° C,1.0 - 4.0kgf/cm2 (If inlet TDS > 200 ppm ,extra pretreatment filter is recommended)
Purification system
Pretreatment unit PP filter× 1, Special spun fiber filter× 2 5um PP deep filter Special active carbon filter× 2 RO unit 100GPD RO membrane× 1 Subsequent unit Deionization purification column (Imported resin) × 2
Pretreatment unit PP filter× 1, Special spun fiber filter× 2 5um PP deep filter Special active carbon filter× 2 RO unit 200GPD RO membrane× 1 Subsequent unit Deionization purification column (Imported resin) × 3
Pure water quality
Ion rejection rate 97%~99% (New RO membrane) Organic rejection rate > 99%,when MW > 200 Dalton Resistivity 15 - 18.2M Ω .cm P articles and bacteria rejection rate > 99%
Ion rejection rate 97%~99% (New RO membrane) Organic rejection rate > 99%,when MW > 200 Dalton Resistivity 15 - 18.2M Ω .cm P articles and bacteria rejection rate > 99%
Resistivity
15~18.2M Ω .cm
15~18.2M Ω .cm
Conductivity
0.055 - 0.067 μ s/cm
0.055 - 0.067 μ s/cm
Flow rate
2.0 Liters/min ( when there is water in the water tank)
2.0 Liters/min ( when there is water in the water tank)
Water Quality Monitor
TDS/conductivity test pen
TDS/conductivity test pen
Consumption
72W
72W
Power supply
AC220V,50/60Hz(Standard)
AC220V,50/60Hz(Standard)
External Size (H× W× D)
410*220*420mm
410*220*420mm
Package size (H× W× D)
600*490*580mm
600*490*580mm
Gross Weight
35kg
35kg

Bu serideki modelleri karşılaştırın

Aşağıdaki farklar, her model için yayımlanan teknik özelliklerden alınmıştır. Nihai konfigürasyonu teklifinizde teyit edin.

Bu model HWP-V serisine aittir. Seriye genel bakış sayfasında tüm modeller yan yana listelenir. Seriye genel bakışı açın

ParametreHWP-IHWP-IIHWP-IIIBu modelHWP-IVHWP-V
Water Output TypeRO water outlet*1 and DI water outlet*1 / RO water outlet*1 and DI water outlet*1RO Water / RO WaterRO and DI Water / RO and DI WaterR O water / RO water / RO water / RO waterRO and DI water / RO and DI water / RO and DI water / RO and DI water
Water Output Speed10 L/H / 15 L/H15L/H / 30L/H15L/H / 30L/H45L/H / 63L/H / 94L/H / 125L/H45L/H / 63L/H / 94L/H / 125L/H
Purifying ProcedurePF+AC+RO+DI / PF+AC+RO+DIPF+AC+RO+ AC / PF+AC+RO+ ACPF+AC+RO+DI / PF+AC+RO+DI——
Water Supply RequirementWhen working, the inlet water pressure is 0.1 - 0.3Mpa, and the water quality meets the requirements of GB5749,15 - 35 ° C / When working, the inlet water pressure is 0.1 - 0.3Mpa, and the water quality meets the requirements of GB5749,15 - 35 ° CTap water:TDS<200 ppm,5~45° C,1.0 - 4.0kg/c / Tap water:TDS<200 ppm,5~45° C,1.0 - 4.0kg/cTap water:TDS<200 ppm,5~45° C,1.0 - 4.0kgf/cm2 (If inlet TDS > 200 ppm ,extra pretreatment filter is recommended) / Tap water:TDS<200 ppm,5~45° C,1.0 - 4.0kgf/cm2 (If inlet TDS > 200 ppm ,extra pretreatment filter is recommended)T ap water: TDS 200ppm, extra pretreatment filter is recommended) / T ap water: TDS 200ppm, extra pretreatment filter is recommended) / T ap water: TDS 200ppm, extra pretreatment filter is recommended) / T ap water: TDS 200ppm, extra pretreatment filter is recommended)Tap water: TDS 200ppm, extra pretreatment filter is recommended) / Tap water: TDS 200ppm, extra pretreatment filter is recommended) / Tap water: TDS 200ppm, extra pretreatment filter is recommended) / Tap water: TDS 200ppm, extra pretreatment filter is recommended)
Purification system10’’PP filter×1+10’’Activated carbon ×2 / 10’’PP filter×1+10’’Activated carbon ×2—Pretreatment unit PP filter× 1, Special spun fiber filter× 25um PP deep filter Special active carbon filter× 2 RO unit 100GPD RO membrane× 1 Subsequent unit Deionization purification column (Imported resin) × 2 / Pretreatment unit PP filter× 1, Special spun fiber filter× 25um PP deep filter Special active carbon filter× 2 RO unit 200GPD RO membrane× 1 Subsequent unit Deionization purification column (Imported resin) × 3——
Flow rate167 ml/min / 250ml/min2 Liters/min (with pressure tank) / 2 Liters/min (with pressure tank)2.0 Liters/min ( when there is water in the water tank) / 2.0 Liters/min ( when there is water in the water tank)——
Water Quality Monitor——TDS/conductivity test pen / TDS/conductivity test penTDS/conductivity test pen / TDS/conductivity test pen / TDS/conductivity test pen / TDS/conductivity test pen—
Consumption46W / 46W—72W / 72W120W / 240W / 240W / 240W120W / 240W / 240W / 240W
Power supplyAC220 V± 10%,50Hz ± 10% / AC220 V± 10%,50Hz ± 10%AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional)AC220V,50/60Hz(Standard) / AC220V,50/60Hz(Standard)AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional)AC220V, 50/60Hz(Standard) / AC220V, 50/60Hz(Standard) / AC220V, 50/60Hz(Standard) / AC220V, 50/60Hz(Standard)
External Size (H× W× D)—410*220*420mm / 410*220*420mm410*220*420mm / 410*220*420mm640*540*1110mm / 640*540*1110mm / 640*540*1110mm / 640*540*1110mm640*540*1110mm / 640*540*1110mm / 640*540*1110mm / 640*540*1110mm
Package size (H× W× D)—600*490*580mm / 600*490*580mm600*490*580mm / 600*490*580mm650*750*1280mm / 650*750*1280mm / 650*750*1280mm / 650*750*1280mm650*750*1280mm / 650*750*1280mm / 650*750*1280mm / 650*750*1280mm
Purification system Pretreatment unit—PP filter× 1 + PP cotton filter× 1 / PP filter× 1 + PP cotton filter× 1—20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 120" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1
RO unit—100GPD RO membrane× 1 / 200GPD RO membrane× 1—300 GPD RO membrane× 1 / 400 GPD RO membrane× 1 / 600 GPD RO membrane× 1 / 400 GPD RO membrane× 2300 GPD RO membrane× 1 / 400 GPD RO membrane× 1 / 600 GPD RO membrane× 1 / 400 GPD RO membrane× 2
Pure water quality Ion rejection rate—97%~99% (New RO membrane) / 97%~99% (New RO membrane)—97%~99% (New RO membrane) / 97%~99% (New RO membrane) / 97%~99% (New RO membrane) / 97%~99% (New RO membrane)—
Organic rejection rate—99%,when MW > 200 Dalton / 99%,when MW > 200 Dalton—> 99%,when MW > 200 Dalton / > 99%,when MW > 200 Dalton / > 99%,when MW > 200 Dalton / > 99%,when MW > 200 Dalton—
Bacteria—<0.1cfu (with optional 0.45+0.1 μ m PES terminal filter) / <0.1cfu (with optional 0.45+0.1 μ m PES terminal filter)—<0.01cfu/ml (with optional 0.2 μ m PES terminal filter) / <0.01cfu/ml (with optional 0.2 μ m PES terminal filter) / <0.01cfu/ml (with optional 0.2 μ m PES terminal filter) / <0.01cfu/ml (with optional 0.2 μ m PES terminal filter)—

Konfigürasyon

  • Main body (include 1 set of purification column)
  • 15L water tank
  • Accessory pack

Seçenekler ve aksesuarlar

  • AC110V, 60HZ power supply