
Etilen Oksit Gaz Sterilizatörü EO-HSeries
Giriş — Etilen Oksit Gaz Sterilizatörü
The EO-Hseries Ethylene Oxide Gas Sterilizer offers a vertical, electric heating solution for efficient sterilization. Available in multiple volumes (70L to 285L), it features a 3.5-inch LCD display, a 304 anti-corrosion stainless steel sterilization room, and a full-automatic control system for one-click operation. Advanced sensors monitor temperature, humidity, and pressure, ensuring precise sterilization conditions.
Temel Özellikler — EO-HSeries
- 3.5-inch LCD display
- 304 anti-corrosion stainless steel sterilization room
- Automatic ventilation (5 cycles, every 15 minutes)
- Full-automatic control system (one-click start to finish)
- Oil-free vacuum pump
Etilen Oksit Gaz Sterilizatörü Teknik Özellikler
PARAMETER | SPECIFICATION |
|---|---|
Product name | Ethylene Oxide Sterilizer |
Product form | Vertical |
Heating method | Electric heating |
Power / Volume / Chamber size | EO - H80: 2.6 KVA / 70L (Liner size: 585 x 275 x 422mm)
EO - H120: 3.0KVA / 105L (Liner size:585 x 375 x 472mm)
EO - H220: 3.3KVA / 195L (Liner size:700 x 505 x 552mm)
EO - H330: 3.6KVA / 285L (Liner size:760 x 545 x 682mm) |
Power | AC220V, 50Hz |
Temperature display | 3.5 inch LCD display |
Material of Sterilization Room | 304 anti - corrosion stainless steel |
Outer box material | Carbon steel spray plastic |
Temperature during sterilization | 50 ℃ ± 3 ℃ |
Working pressure | - 60kpa |
Highest anti - stress value | - 140kpa |
Humidity during sterilization | 45% - 80% |
Selected gas | Pure ethylene oxide gas |
Sterilization time | 0 - 99 hours adjustable |
Air Replacement | Automatic ventilation, 5 cycles of ventilation, every 1 5 minutes |
Full - automatic control system | One - click start to finish, the whole process is completed automatically |
Sterilization record | The system can store 500 pots of sterilization records |
Display status | Display operating status, temperature, humidity, pressure, sterilization time, residual gas treatment time, times, steam generator temperature. |
Humidity Sensor | The built - in humidity sensor automatically detects the humidity in the cavity. |
Pressure Sensor | The built - in pressure sensor automatically d etects the pressure in the cavity |
Temperature Sensor | The built - in temperature sensor automatically detects the temperature in the cavity, the accurate range is 50 ℃ ± 3 ℃ . |
Vacuum system | Use oil - free vacuum pump. |
Seal door | 304 stainless steel aluminum material, thickness ≥ 2mm, pressure resistance 200Kpa. |
Humidification System | Using pulse steam humidification |
Residual gas treatment device | The filtration rate of the filter to the particle diameter ≥0.3 μ m is not less than 99.5% |
Vacuum rate | Under no - load con ditions, the time for the sterilizer to be vacuumed from normal pressure to - 60 kPa ≤ 30 min |
Automatic dosing | Puncture technology built into the sterilization chamber. |
Heating system | The explosion - proof electric heating device is used in the sterilization chamber |
Multiple protection functions | With over - voltage and over - temperature protection functions, it is more safe and reliable |
Alarm system | Have high temperature alarm system, ultra low pressure alarm system |
Bu serideki modelleri karşılaştırın
Aşağıdaki farklar, her model için yayımlanan teknik özelliklerden alınmıştır. Nihai konfigürasyonu teklifinizde teyit edin.
Bu model EO-H40 serisine aittir. Seriye genel bakış sayfasında tüm modeller yan yana listelenir. Seriye genel bakışı açın
| Parametre | EO-H40 | EO-HSeriesBu model |
|---|---|---|
| Product form | Desktop | Vertical |
| Power | 1.3KVA | AC220V, 50Hz |
| Outer box material | ABS plastic | Carbon steel spray plastic |
EO-HSeries için garanti ve satış sonrası hizmet
HQS bu model için garanti, yedek parça ve onarımı nasıl yürütür.
- Garanti süresi
- Ana ünite garantisi modele ve siparişe göre değişir. Geçerli süre teklifinizde ve sipariş onayınızda belirtilir; lütfen satın almadan önce teyit edin.
- Kapsam
- Garanti süresi içinde üretim veya kalite kusurundan kaynaklanan bir arıza ücretsiz onarılır. Sarf malzemeleri ve aksesuarlar, hatalı kullanımdan doğan hasarlar ve seri numarası etiketi değiştirilmiş ya da çıkarılmış cihazlar ana ünite garantisi kapsamında değildir.
- Yedek parça
- Yedek parça ve teknik destek, HQS’nin ürünü sevk ettiği tarihten itibaren en az sekiz yıl sağlanır.
- Yanıt süresi
- Servis taleplerine bir iş günü içinde ilk yanıt verilir. Lütfen seri numarasını, modeli, ana ünite sürümünü ve sorunun açıklamasını gönderin.
- Garanti içi onarım
- Onaylanmış bir garanti arızası yedek parça gerektiriyorsa HQS parçayı kendi masrafıyla gönderir; arızalı parça HQS’ye iade edilir.
- Garanti sonrası onarım
- HQS önce maliyet bazlı bir teklif ve proforma fatura gönderir. Onarılan parçalar iade edilmeden önce test edilir. E-posta veya telefonla teknik destek ücretsizdir.
İlgili Ürünler

Etilen Oksit Gaz Sterilizatörü
Model: EO-H40

Dijital Kaset Sterilizatörü
Model: N-5L,N-5L+

H2O2 Düşük Sıcaklık Plazma Sterilizatörü
Model: HO-D100,D130,D220

H2O2 Düşük Sıcaklık Plazma Sterilizatörü
Model: HO-DZ100,DZ130,DZ220