The US-T5 Color Doppler Ultrasound Scanner is a high-performance diagnostic system featuring a Windows 8 operating system. It offers advanced imaging capabilities including Pulse Doppler Imaging (PW), Direction Power Doppler Imaging (DPDI), and real-time three-synchronous imaging for B/C/D modes. Enhanced by Compound Imaging and Tissue Harmonic Imaging (THI), the T5 provides superior image quality with flexible display modes like 2B/4B.
Temel Özellikler — US-T5
- Operating system: Windows 8 operating system
- Pulse Doppler Imaging (PW)
- Direction Power Doppler Imaging (DPDI)
- B/C/D Real - time Three Synchronous Imaging
- Compound Imaging
- Tissue Harmonic Imaging (THI)
- 2B/4B Imaging Modes
- System language option: Chinese, English, French, Russian, Spanish
- Main monitor: ≥ 21.5 inch
- Host build in 128G hard disk, start fast and stable.
- Movie playback: ≥600 frames.
- Report type: ≥6 .
- One key fast report graphic and text management .
- Image format: BMP, DCM, JPG .
- Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by number, check number, name and so on.
Renkli Doppler Ultrason Cihazı Teknik Özellikler
PARAMETER | SPECIFICATION |
|---|---|
2D Imaging Mode Gain | 0 - 100, Step 1 adjustable |
TGC | 8 segment adjustable |
Dynamic | 20 - 280, 20 levels adjustable |
Pseudo color | 0 - 11, adjustable |
Sound power | 5% - 100%, step 5% adjustable |
Body mark | ≥ 18 kinds optional |
Maximum focus | ≥6, which can be moved throughout the whole process |
Grey scale map | 0 - 7, 7 levels adjustable |
Filter | 0 - 4 |
Scanning range | 50% - 100% |
Frame correlation | 0 - 4, 4 level adjustable |
Line density | low, middle, high, 3 levels adjustable |
Noise reduction | 0 - 14 , 4 level adjustable |
The screen has real - time display of sound power, probe frequency, dynamic range, pseudo color, gray scale and other 14 parameters can be adjusted. | |
Color Doppler Imaging Mode Color Frame correlation | 0 - 12, 12 levels adjustable |
Color map | 0 - 7 , 7 levels adjustable |
Color flip | adjustable |
Base line | 11 levels, adjustable |
Line density | low, high, 2 levels adjustable |
Filter | 0 - 5 levels adjustable |
B / C real - time split screen mode | |
Spectral Doppler Imaging Mode Sampling volume angle correction | - 80° ~ 80° adjustable |
Sample volume | 0.5mm - 20mm adjustable |
Frequency | 2 .5MHz, 3 .0MHz |
Base line | 11 levels, adjustable |
Pseudo color | 0 - 5 |
Parameter display | ≥4 kinds, adjustable |
Speed scale | 32.8–328 cm/s (different probes have different ranges) |
Spectrum envelope function | real time automatic spectrum envelope, manual spectrum envelope, and other. |
The system automatically analyses and displays various data such as PS, ED, RI, PI, S/D, HR, etc . | |
Grey map | 0 - 7 |
Filter | 0 - 8 |
Dynamic range | 10 - 95, step 5 |
Noise reduction | 0 - 28 |
Sound volume | 0 - 100 |
3D Imaging (optional) Fast angle supports | 0° , 90° , 180° , 270° rotation for 3D View |
Display mode | one image, two images, four images |
Reconstruction mode | Real Skin, Surface, Max, Min, X Rax |
Pseudo color | 0 - 7, 7 levels adjustable |
Zoom | 5 levels |
Contrast | 0% - 100% |
Threshold level | 0% - 100% |
Smooth | ≥3 levels |
Image rotation | X/Y/Z Axis |
Brightness | 0% - 100% |
4D Imaging (optional) Fast angle supports | 0° , 90° , 180° , 270° rotation for 3D View |
Display model | one image, two images, four images |
Reconstruction mode | Real Skin, Surface, Max, Min, X Rax |
Pseudo color | 0 - 7, 7 levels adjustable |
Zoom | 5 levels |
Contrast | 0% - 100% |
Threshold level | 0% - 100% |
Smooth | ≥3 levels, adjustable |
Image rotation | X/Y/Z Axis |
Line density | 2 levels, adjustable |
Measurement and Analysis General measurement | distance, area, angle, time, slope, heart rate, speed, acceleration, blood flow path, blood flow spectrum trace, resistance index/pulsation index, etc |
OB measurement data | Cannie, Feline, Bovine, Ovine, Equine |
Measurement line color and type can be adjusted at will (including the activation color and the completion color) | |
Measurement result display position and font size can be adjusted as needed | |
Professional data package | Abdomen, OB, Urology, etc |
Various Probes Convex probe (detecting depth: 30 - 255mm) Fundamental Frequency | 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz
Harmonic
Frequency: H4.0MHz/ H5.0MHz |
Linear probe (detecting depth: 20 - 128mm) Fundamental Frequency | 6.0MHz/ 7.5MHz/ 8.5MHz/ 10.0MHz
Harmonic
Frequency: H10.0MHz |
Rectal probe (detecting depth: 30 - 156mm) Fundamental Frequency | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic
Frequency: H8.0MHz |
Phased array probe (detecting depth: 100 - 244mm) Fundamental Frequency | 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz
Harmonic
Frequency: H3.0MHz/ H4.0MHz |
4D volume probe (detecting depth: 30 - 237mm) Fundamental Frequency | 2.0MHz/ 3.0MHz/ 4.5MHz/ 6.0MHz
Harmonic
Frequency: H5.0MHz |
Micro - convex probe R15 (detecting depth: 30 - 111mm) Fundamental Frequency | 4.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz
Harmonic
Frequency: H8.0MHz |
Micro - convex probe R11 (detecting depth: 30 - 111mm) Fundamental Frequency | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic
Frequency: H8.0MHz |
Micro - convex probe R20 (detecting depth: 30 - 111mm) Fundamental Frequency | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic
Frequency: H8.0MHz |
Bu serideki modelleri karşılaştırın
Aşağıdaki farklar, her model için yayımlanan teknik özelliklerden alınmıştır. Nihai konfigürasyonu teklifinizde teyit edin.
Bu model US-P60 serisine aittir. Seriye genel bakış sayfasında tüm modeller yan yana listelenir. Seriye genel bakışı açın
| Parametre | US-E80 | US-L6 | US-P60 | US-T5Bu model |
|---|---|---|---|---|
| Pseudo color | — | 0 - 12, adjustable | — | 0 - 11, adjustable |
| Noise reduction | — | 0 - 14 | — | 0 - 14 , 4 level adjustable |
| Color map | — | 0 - 3, 3 levels adjustable | — | 0 - 7 , 7 levels adjustable |
| Frequency | — | 4.5MHz, 6.0MHz | — | 2 .5MHz, 3 .0MHz |
| Speed scale | — | 3 - 2288cm/s (different probes have different ranges) | — | 32.8–328 cm/s (different probes have different ranges) |
| Spectrum envelope function | — | real time automatic spectrum envelope, manual spectrum envelope, and other. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, HR, ACC, etc | — | real time automatic spectrum envelope, manual spectrum envelope, and other. |
| Display mode | B, B+B, B+M, M, 4B | — | — | one image, two images, four images |
| Zoom | — | — | 1.5×, 2.0×, 2.5×, 3.0×, 3.5×, 4.0×, 4.5×, 5.0× ve 10× | 5 levels |
| Linear probe (detecting depth: 20 - 128mm) Fundamental Frequency | — | 6.0MHz/ 7.5MHz/ 8.5MHz/ 10.0MHz | — | 6.0MHz/ 7.5MHz/ 8.5MHz/ 10.0MHz Harmonic Frequency: H10.0MHz |
| Micro - convex probe R15 (detecting depth: 30 - 111mm) Fundamental Frequency | — | 4.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz | — | 4.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz Harmonic Frequency: H8.0MHz |
| Micro - convex probe R11 (detecting depth: 30 - 111mm) Fundamental Frequency | — | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz | — | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz Harmonic Frequency: H8.0MHz |
Seçenekler ve aksesuarlar
- Video printer (optional)
- Laser printer (optional)
- Trolley
- 3D Imaging (optional)
- 4D Imaging (optional)
US-T5 için garanti ve satış sonrası hizmet
HQS bu model için garanti, yedek parça ve onarımı nasıl yürütür.
- Garanti süresi
- Ana ünite garantisi modele ve siparişe göre değişir. Geçerli süre teklifinizde ve sipariş onayınızda belirtilir; lütfen satın almadan önce teyit edin.
- Kapsam
- Garanti süresi içinde üretim veya kalite kusurundan kaynaklanan bir arıza ücretsiz onarılır. Sarf malzemeleri ve aksesuarlar, hatalı kullanımdan doğan hasarlar ve seri numarası etiketi değiştirilmiş ya da çıkarılmış cihazlar ana ünite garantisi kapsamında değildir.
- Yedek parça
- Yedek parça ve teknik destek, HQS’nin ürünü sevk ettiği tarihten itibaren en az sekiz yıl sağlanır.
- Yanıt süresi
- Servis taleplerine bir iş günü içinde ilk yanıt verilir. Lütfen seri numarasını, modeli, ana ünite sürümünü ve sorunun açıklamasını gönderin.
- Garanti içi onarım
- Onaylanmış bir garanti arızası yedek parça gerektiriyorsa HQS parçayı kendi masrafıyla gönderir; arızalı parça HQS’ye iade edilir.
- Garanti sonrası onarım
- HQS önce maliyet bazlı bir teklif ve proforma fatura gönderir. Onarılan parçalar iade edilmeden önce test edilir. E-posta veya telefonla teknik destek ücretsizdir.
İlgili Ürünler

Renkli Doppler Ultrason Cihazı
Model: US-E80

Renkli Doppler Ultrason Cihazı
Model: US-L6

Renkli Doppler Ultrason Cihazı US-P60
Model: US-P60

Kablosuz Ultrason Cihazı
Model: US-3C/US-3L