Aparat USG z kolorowym Dopplerem US-T5
Wprowadzenie — Aparat USG z kolorowym Dopplerem
The US-T5 Color Doppler Ultrasound Scanner is a high-performance diagnostic system featuring a Windows 8 operating system. It offers advanced imaging capabilities including Pulse Doppler Imaging (PW), Direction Power Doppler Imaging (DPDI), and real-time three-synchronous imaging for B/C/D modes. Enhanced by Compound Imaging and Tissue Harmonic Imaging (THI), the T5 provides superior image quality with flexible display modes like 2B/4B.
Najważniejsze funkcje — US-T5
- Operating system: Windows 8 operating system
- Pulse Doppler Imaging (PW)
- Direction Power Doppler Imaging (DPDI)
- B/C/D Real - time Three Synchronous Imaging
- Compound Imaging
- Tissue Harmonic Imaging (THI)
- 2B/4B Imaging Modes
- System language option: Chinese, English, French, Russian, Spanish
- Main monitor: ≥ 21.5 inch
- Host build in 128G hard disk, start fast and stable.
- Movie playback: ≥600 frames.
- Report type: ≥6 .
- One key fast report graphic and text management .
- Image format: BMP, DCM, JPG .
- Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by number, check number, name and so on.
Aparat USG z kolorowym Dopplerem Specyfikacja
PARAMETER | SPECIFICATION |
|---|---|
2D Imaging Mode Gain | 0 - 100, Step 1 adjustable |
TGC | 8 segment adjustable |
Dynamic | 20 - 280, 20 levels adjustable |
Pseudo color | 0 - 11, adjustable |
Sound power | 5% - 100%, step 5% adjustable |
Body mark | ≥ 18 kinds optional |
Maximum focus | ≥6, which can be moved throughout the whole process |
Grey scale map | 0 - 7, 7 levels adjustable |
Filter | 0 - 4 |
Scanning range | 50% - 100% |
Frame correlation | 0 - 4, 4 level adjustable |
Line density | low, middle, high, 3 levels adjustable |
Noise reduction | 0 - 14 , 4 level adjustable |
The screen has real - time display of sound power, probe frequency, dynamic range, pseudo color, gray scale and other 14 parameters can be adjusted. | |
Color Doppler Imaging Mode Color Frame correlation | 0 - 12, 12 levels adjustable |
Color map | 0 - 7 , 7 levels adjustable |
Color flip | adjustable |
Base line | 11 levels, adjustable |
Line density | low, high, 2 levels adjustable |
Filter | 0 - 5 levels adjustable |
B / C real - time split screen mode | |
Spectral Doppler Imaging Mode Sampling volume angle correction | - 80° ~ 80° adjustable |
Sample volume | 0.5mm - 20mm adjustable |
Frequency | 2 .5MHz, 3 .0MHz |
Base line | 11 levels, adjustable |
Pseudo color | 0 - 5 |
Parameter display | ≥4 kinds, adjustable |
Speed scale | 32.8–328 cm/s (different probes have different ranges) |
Spectrum envelope function | real time automatic spectrum envelope, manual spectrum envelope, and other. |
The system automatically analyses and displays various data such as PS, ED, RI, PI, S/D, HR, etc . | |
Grey map | 0 - 7 |
Filter | 0 - 8 |
Dynamic range | 10 - 95, step 5 |
Noise reduction | 0 - 28 |
Sound volume | 0 - 100 |
3D Imaging (optional) Fast angle supports | 0° , 90° , 180° , 270° rotation for 3D View |
Display mode | one image, two images, four images |
Reconstruction mode | Real Skin, Surface, Max, Min, X Rax |
Pseudo color | 0 - 7, 7 levels adjustable |
Zoom | 5 levels |
Contrast | 0% - 100% |
Threshold level | 0% - 100% |
Smooth | ≥3 levels |
Image rotation | X/Y/Z Axis |
Brightness | 0% - 100% |
4D Imaging (optional) Fast angle supports | 0° , 90° , 180° , 270° rotation for 3D View |
Display model | one image, two images, four images |
Reconstruction mode | Real Skin, Surface, Max, Min, X Rax |
Pseudo color | 0 - 7, 7 levels adjustable |
Zoom | 5 levels |
Contrast | 0% - 100% |
Threshold level | 0% - 100% |
Smooth | ≥3 levels, adjustable |
Image rotation | X/Y/Z Axis |
Line density | 2 levels, adjustable |
Measurement and Analysis General measurement | distance, area, angle, time, slope, heart rate, speed, acceleration, blood flow path, blood flow spectrum trace, resistance index/pulsation index, etc |
OB measurement data | Cannie, Feline, Bovine, Ovine, Equine |
Measurement line color and type can be adjusted at will (including the activation color and the completion color) | |
Measurement result display position and font size can be adjusted as needed | |
Professional data package | Abdomen, OB, Urology, etc |
Various Probes Convex probe (detecting depth: 30 - 255mm) Fundamental Frequency | 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz
Harmonic
Frequency: H4.0MHz/ H5.0MHz |
Linear probe (detecting depth: 20 - 128mm) Fundamental Frequency | 6.0MHz/ 7.5MHz/ 8.5MHz/ 10.0MHz
Harmonic
Frequency: H10.0MHz |
Rectal probe (detecting depth: 30 - 156mm) Fundamental Frequency | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic
Frequency: H8.0MHz |
Phased array probe (detecting depth: 100 - 244mm) Fundamental Frequency | 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz
Harmonic
Frequency: H3.0MHz/ H4.0MHz |
4D volume probe (detecting depth: 30 - 237mm) Fundamental Frequency | 2.0MHz/ 3.0MHz/ 4.5MHz/ 6.0MHz
Harmonic
Frequency: H5.0MHz |
Micro - convex probe R15 (detecting depth: 30 - 111mm) Fundamental Frequency | 4.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz
Harmonic
Frequency: H8.0MHz |
Micro - convex probe R11 (detecting depth: 30 - 111mm) Fundamental Frequency | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic
Frequency: H8.0MHz |
Micro - convex probe R20 (detecting depth: 30 - 111mm) Fundamental Frequency | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic
Frequency: H8.0MHz |
Porównanie modeli z tej serii
Różnice podano na podstawie specyfikacji opublikowanych dla poszczególnych modeli. Ostateczną konfigurację prosimy potwierdzić w ofercie.
Ten model należy do serii US-P60. Na stronie serii zestawiono wszystkie modele. Przegląd serii
| Parametr | US-E80 | US-L6 | US-P60 | US-T5Ten model |
|---|---|---|---|---|
| Pseudo color | — | 0 - 12, adjustable | — | 0 - 11, adjustable |
| Noise reduction | — | 0 - 14 | — | 0 - 14 , 4 level adjustable |
| Color map | — | 0 - 3, 3 levels adjustable | — | 0 - 7 , 7 levels adjustable |
| Frequency | — | 4.5MHz, 6.0MHz | — | 2 .5MHz, 3 .0MHz |
| Speed scale | — | 3 - 2288cm/s (different probes have different ranges) | — | 32.8–328 cm/s (different probes have different ranges) |
| Spectrum envelope function | — | real time automatic spectrum envelope, manual spectrum envelope, and other. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, HR, ACC, etc | — | real time automatic spectrum envelope, manual spectrum envelope, and other. |
| Display mode | B, B+B, B+M, M, 4B | — | — | one image, two images, four images |
| Linear probe (detecting depth: 20 - 128mm) Fundamental Frequency | — | 6.0MHz/ 7.5MHz/ 8.5MHz/ 10.0MHz | — | 6.0MHz/ 7.5MHz/ 8.5MHz/ 10.0MHz Harmonic Frequency: H10.0MHz |
| Micro - convex probe R15 (detecting depth: 30 - 111mm) Fundamental Frequency | — | 4.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz | — | 4.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz Harmonic Frequency: H8.0MHz |
| Micro - convex probe R11 (detecting depth: 30 - 111mm) Fundamental Frequency | — | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz | — | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz Harmonic Frequency: H8.0MHz |
Opcje i akcesoria
- Video printer (optional)
- Laser printer (optional)
- Trolley
- 3D Imaging (optional)
- 4D Imaging (optional)
Gwarancja i serwis posprzedażowy dla US-T5
Jak HQS obsługuje gwarancję, części zamienne i naprawy tego modelu.
- Okres gwarancji
- Gwarancja na jednostkę główną zależy od modelu i zamówienia. Obowiązujący okres jest podany w ofercie i potwierdzeniu zamówienia; prosimy sprawdzić go przed zakupem.
- Zakres
- Usterka spowodowana wadą produkcyjną lub jakościową w okresie gwarancji jest naprawiana bezpłatnie. Materiały eksploatacyjne i akcesoria, uszkodzenia wynikające z niewłaściwego użytkowania oraz urządzenia ze zmienioną lub usuniętą etykietą numeru seryjnego nie są objęte gwarancją na jednostkę główną.
- Części zamienne
- Części zamienne i wsparcie techniczne są dostępne przez co najmniej osiem lat od daty wysyłki przez HQS.
- Czas odpowiedzi
- Zgłoszenia serwisowe otrzymują pierwszą odpowiedź w ciągu jednego dnia roboczego. Prosimy podać numer seryjny, model, wersję jednostki głównej i opis problemu.
- Naprawy gwarancyjne
- Jeśli potwierdzona usterka gwarancyjna wymaga części zamiennej, HQS wysyła ją na własny koszt, a uszkodzona część jest odsyłana do HQS.
- Naprawy pogwarancyjne
- HQS najpierw przesyła wycenę według kosztów i fakturę pro forma. Naprawione części są testowane przed odesłaniem. Pomoc techniczna przez e-mail lub telefon jest bezpłatna.
Podobne produkty

Aparat USG z kolorowym Dopplerem
Model: US-E80

Aparat USG z kolorowym Dopplerem
Model: US-L6

Aparat USG z kolorowym Dopplerem US-P60
Model: US-P60

Bezprzewodowy aparat USG
Model: US-3C/US-3L