Monitor wieloparametrowy HM-8V - Multiparameter Monitor | HQS Medical
Monitor wieloparametrowy

Monitor wieloparametrowy HM-8V

Model: HM-8V

Wprowadzenie — Monitor wieloparametrowy

The HM - 8V Multiparameter Monitor, featuring an 8-inch high-resolution color TFT LCD display, provides comprehensive patient monitoring capabilities. It includes six standard parameters (ECG, RESP, NIBP, SpO2, TEMP, PR) and advanced features such as arrhythmic analysis, real-time ST segment monitoring, and resistance to defibrillator and electrosurgical interference. With extensive data storage and networking capacity, it is designed for efficient and reliable patient care.

Najważniejsze funkcje — HM-8V

  • 8-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, TEMP, PR
  • Efficient resistance to interference of defibrillator and electrosurgical cautery
  • SPO2 can testing for 0.1% Weak
  • RA - LL impedance Respiration
  • Trend Coexist Display
  • OxyCRG DyNamic View Display
  • Bed to Bed view Display
  • Networking capacity and nurse calling system
  • Built - in rechargeable battery 22 00mAh
  • Large volume of tabular and graphic trends information storage and easy to recall
  • Anti - ESU, anti - defibrillator
Cennik e-mailem

Wystarczy podać adres e-mail, a prześlemy ofertę i kartę katalogową tego modelu – zwykle w ciągu jednego dnia roboczego.

Share:

Model-specific documentation

Documents for HM-8V

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

HM-8V Multiparameter Monitor product datasheet

Public PDF

HQS datasheet for the HM-8V: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
HM-8V
Length
4 pages
File
PDF · 220 KB
Web copy prepared
Need a different language or configuration-specific document?

Monitor wieloparametrowy Specyfikacja

Parameter
Value
ECG Lead Mode
5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
Lead selection
I, II, III, avR, avL, avF, V
Waveform
2 ch
Lead mode
3 Leads (R, L, F or RA, LA, LL)
Lead selection
I, II, III
Waveform
1 ch
Gain
‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
Heart Rate Range
15 ~ 300 bpm
Accuracy
±1% or ±1bpm, which great
Resolution
1 bpm
Sensitivity
>200 (uV P - P)
Differential Input Impedance
> 5 M Ω
CMRR - Monitor
> 105 dB
CMRR - Operation
> 105 dB
CMRR - Diagnosis
> 85 dB
Electrode offset potential
± 300mV
Leakage Current
<10uA
Baseline Recovery
< 3S after Defi.
ECG Signal Range
± 8 m V (Vp - p)
Bandwidth - Surgery
1 ~ 15 Hz
Bandwidth - Monitor
0.5 ~ 35 Hz
Bandwidth - Diagnostic
0.05 ~ 100 Hz
Calibration Signal
1 (mV p - p)
Accuracy
± 5%
ST Segment Monitoring Range
Measure and Alarm - 2.0 ~ +2.0 mV
ARR Detecting Type
ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm
Available
Review
Available
Respiration Method
Impedance between R - F (RA - LL)
Differential Input Impedance
>2.5 M Ω
Measuring Impedance Range
0.3 ~ 5.0 Ω
Base line Impedance Range
0 ~ 2.5 K Ω
Bandwidth
0.3 ~ 2.5 Hz
Resp. Measuring Range - Adult
0 ~ 120 rpm
Resp. Measuring Range - Neo/Ped
0 ~ 150 rpm
Resp. Alarm Range - High alarm range limit
8~120 rpm
Resp. Alarm Range - Low alarm range limit
6~120 rpm
Resolution
1 rpm
Accuracy
± 2 rpm
Apnea Alarm
10 ~ 40 S
NIBP Method
Oscillometric
Mode
Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode
5 Min
Pulse Rate Range
40 ~ 240 bpm
Alarm Type
SYS, DIA, MEAN
Measuring and alarm range - SYS
40 ~ 280 mmHg
Measuring and alarm range - DIA
10 ~ 225 mmHg
Measuring and alarm range - MEAN
20 ~ 240 mmHg
Resolution Pressure
1mmHg
Accuracy Pressure Maximum Mean error
± 5mmHg
Accuracy Pressure Maximum Standard deviation
± 8mmHg
SpO2 Measuring Range
0 ~ 100 %
SpO2 Alarm Range
0 ~ 100 %
Resolution
1 %
Accuracy
70% ~ 100% ± 2 % ; 0% ~ 69% unspecified
Actualization interval
about 1 Sec.
Alarm Delay
10 Sec.
Pulse Rate Measuring and Alarm Range
20~250bpm
Resolution
1bpm
Accuracy
± 3bpm
Temperature Measuring and Alarm Range
0 ~ 50° C
Resolution
0.1° C
Accuracy
± 0.1° C
Actualization interval
about 1 Sec.
Average Time Constant
<10 Sec.

Porównanie modeli z tej serii

Różnice podano na podstawie specyfikacji opublikowanych dla poszczególnych modeli. Ostateczną konfigurację prosimy potwierdzić w ofercie.

Ten model należy do serii HM-12V. Na stronie serii zestawiono wszystkie modele. Przegląd serii

ParametrHM-8VTen modelHM-12VHM-200VHM-500V
ECG Lead Mode5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)5 lead,RA,LA,RL,LL,V5 lead,RA,LA,RL,LL,V
Lead selectionI, II, III, avR, avL, avF, VI, II, III, avR, avL, avF, V, Waveform: 2 chI,II, III,V, AVF,AVL,AVRI,II, III,V, AVF,AVL,AVR
Heart Rate Range15 ~ 300 bpm15 ~ 300 bpm20 - 350BPM25 - 350BPM
Accuracy±1% or ±1bpm, which great±1% or ±1bpm, which great± 2BPM or ± 2% (whichever is greater)± 2BPM or ± 2% (whichever is greater)
Calibration Signal1 (mV p - p)1 (mV p - p), Accuracy: ± 5%——
NIBP MethodOscillometricOscillometricOscillometric with step - down deflationOscillometric with step - down deflation
Measurement time——30 to 50 seconds typical , 120 seconds maximum30 to 50 seconds typical , 180 seconds maximum
Measuring range——25 - 45°0 - 50° C
Range of pulse rate——20 - 350BPM25 - 350BPM
Respiration Measurement range——0 - 120rpm0 - 130rpm
Width——180mm (7.09 inches)324 mm ( 12.76 inches)
Height——129mm (5.08 inches)324 mm ( 12.76 inches)
Weight——2.05 kg (4.52 lbs)3.75 kg (8.27 lbs)

Konfiguracja

  • 5 - lead ECG cable (including RESP)
  • SpO2 sensor
  • NIBP cuff
  • NIBP extension tube
  • TEMP sensor
  • AC power adaptor
  • Operation instruction

Opcje i akcesoria

  • Internal Recorder
  • IBP
  • EtCO2
  • Central Monitoring System
  • Touch Screen
  • VGA
  • Neonate SPO2