Monitor wieloparametrowy
Monitor wieloparametrowy HM-200V
Model: HM-200V
Wprowadzenie — Monitor wieloparametrowy
The HM - 200V Multiparameter Monitor features a 7-inch high-resolution color LCD display and is specifically designed for veterinary use with large measuring ranges for SpO2, pulse rate, and NIBP. It is widely adopted in pet hospitals and animal clinics.
Najważniejsze funkcje — HM-200V
- Special designed logo for veterinary use only
- Variety accessories for veterinary application
- Widely used in pet hospitals and animal clinics etc
Cennik e-mailem
Share:
Monitor wieloparametrowy Specyfikacja
Specification | Value |
|---|---|
ECG Lead mode | 5 lead,RA,LA,RL,LL,V |
Lead selection | I,II, III,V, AVF,AVL,AVR |
ECG waveform | 1 or 3 channels |
Gain selection | ×1/4, ×1/2, ×1, ×2, ×4, auto |
Sweep speed | 6.25mm/s,12.5mm/s,25mm/s,50mm/s |
Heart rate range | 20 - 350BPM |
Accuracy | ± 2BPM or ± 2% (whichever is greater) |
Resolution | 1BPM |
S - T deletion | Yes |
NIBP Method | Oscillometric with step - down deflation |
Range of systolic | 40 to 270mmHg |
Range of mean arterial | 30 to 220mmHg |
Range of diastolic | 20 to 200mmHg |
Measurement time | 30 to 50 seconds typical , 120 seconds maximum |
Alarm range | 20 - 260 (in 1mmHg steps), and OFF |
Temperature Channel | Two |
Measuring range | 25 - 45° |
Accuracy | ± 0.2° C, plus the temperature sensor tolerance |
Resolution | 0.1° C |
SPO2 Range | 0 - 100% |
Accuracy | ± 2 at 70 - 100% |
Resolution | 1% |
Range of pulse rate | 20 - 350BPM |
Resolution | 1BPM |
Respiration Measurement range | 0 - 120rpm |
Accuracy | ± 1rpm |
Resolution | 1rpm |
CO2 (Optional) Range | 0 - 150mmHg |
Accuracy | 0-40 mmHg: ± 2 mmHg; 41-150 mmHg: ± 10% of reading |
Range of Respiration | 2 - 150rpm |
Accuracy | ± 1%rpm |
Preheating time | 10s |
Power | AC input:100 to 240v, 50/60Hz |
Environmental Temperature | - 40 to 75° C(Storage) |
Operating Temperature | 0 to 50° C(Operating) |
Humidity | 15 to 95% (Operating) |
Storage Humidity | 10 to 95% (Storage) |
Battery Full charging time | 3 hours |
Operating time | approx. 4.5 hours |
Power consumption | 80VA |
Dimension Length | 300mm (11.81 inches) |
Width | 180mm (7.09 inches) |
Height | 129mm (5.08 inches) |
Weight | 2.05 kg (4.52 lbs) |
Porównanie modeli z tej serii
Różnice podano na podstawie specyfikacji opublikowanych dla poszczególnych modeli. Ostateczną konfigurację prosimy potwierdzić w ofercie.
Ten model należy do serii HM-12V. Na stronie serii zestawiono wszystkie modele. Przegląd serii
| Parametr | HM-8V | HM-12V | HM-200VTen model | HM-500V |
|---|---|---|---|---|
| ECG Lead mode | 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V) | 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V) | 5 lead,RA,LA,RL,LL,V | 5 lead,RA,LA,RL,LL,V |
| Lead selection | I, II, III, avR, avL, avF, V | I, II, III, avR, avL, avF, V, Waveform: 2 ch | I,II, III,V, AVF,AVL,AVR | I,II, III,V, AVF,AVL,AVR |
| Heart rate range | 15 ~ 300 bpm | 15 ~ 300 bpm | 20 - 350BPM | 25 - 350BPM |
| Accuracy | ±1% or ±1bpm, which great | ±1% or ±1bpm, which great | ± 2BPM or ± 2% (whichever is greater) | ± 2BPM or ± 2% (whichever is greater) |
| NIBP Method | Oscillometric | Oscillometric | Oscillometric with step - down deflation | Oscillometric with step - down deflation |
| Measurement time | — | — | 30 to 50 seconds typical , 120 seconds maximum | 30 to 50 seconds typical , 180 seconds maximum |
| Measuring range | — | — | 25 - 45° | 0 - 50° C |
| Range of pulse rate | — | — | 20 - 350BPM | 25 - 350BPM |
| Respiration Measurement range | — | — | 0 - 120rpm | 0 - 130rpm |
| Width | — | — | 180mm (7.09 inches) | 324 mm ( 12.76 inches) |
| Height | — | — | 129mm (5.08 inches) | 324 mm ( 12.76 inches) |
| Weight | — | — | 2.05 kg (4.52 lbs) | 3.75 kg (8.27 lbs) |
| Calibration Signal | 1 (mV p - p) | 1 (mV p - p), Accuracy: ± 5% | — | — |
Opcje i akcesoria
- CO2 (Optional)