Animal Hyperbaric Oxygen Chambers

Compare hyperbaric oxygen chambers by chamber size, working pressure and climate control rather than by overall cabinet size. The HQS H820, H880 and H890 models use an acrylic chamber on a 304 stainless-steel base with touch-screen control and oxygen concentration monitoring. Treatment pressure, time and patient selection are clinical decisions for the veterinary team; plan the oxygen supply, floor space and power before ordering.

4 Products

How to compare and shortlist models

  • Measure your largest patients against the chamber length and diameter, not the overall unit size.
  • Choose the working pressure range (1.5 ATA or 1.5–2.0 ATA) and whether you need heating, cooling or nebulisation in the chamber.
  • Confirm the oxygen source and flow, electrical supply, room ventilation and safety devices such as the pressure-relief valve.
  • Request the operating manual, safety instructions, installation requirements and service arrangements for the chosen model.

Compare H820-III, H820-II, H880-IV and H890-V hyperbaric oxygen chambers

All four have an acrylic chamber on a 304 stainless-steel base, a 10-inch touch screen and oxygen concentration control from 21% to 95%. H820-III is the compact unit with the smallest chamber; H820-II has a full-size chamber at 1.5 ATA without climate control; H880-IV and H890-V work at 1.5–2.0 ATA and hold the chamber at about 25 °C with heating and cooling, and H890-V adds nebulised drug delivery and UV disinfection. Treatment pressure and time are decisions for the veterinary team.

Published model specifications and quotation checks
Model and instrument typePublished specificationsWhat to specify in your enquiry
H820-IIICompact hyperbaric oxygen chamber
  • Chamber: L682 mm × Ø528 mm
  • Working pressure: 1.5 ATA
  • O2 21–95%; 60% within 10 min
Check the chamber length and diameter against your largest patients, and confirm the oxygen source to be connected.
H820-IIHyperbaric oxygen chamber
  • Chamber: L1,000 mm × Ø610 mm
  • Working pressure: 1.5 ATA
  • O2 21–95%; 60% within 10 min
There is no heating or cooling in this model; plan room temperature, floor space and the oxygen supply.
H880-IVHyperbaric oxygen chamber with heating and cooling
  • Chamber: L1,000 mm × Ø650 mm
  • Working pressure: 1.5–2.0 ATA
  • Holds 25 ± 2 °C by heating and cooling
Choose 110 V/60 Hz or 220 V/50 Hz, and ask whether the Bluetooth ECG wearable is included.
H890-VHyperbaric oxygen chamber with nebulisation
  • Chamber: L1,000 mm × Ø650 mm
  • Working pressure: 1.5–2.0 ATA
  • Nebulised drug delivery and UV disinfection
Confirm the nebuliser, UV and ECG wearable functions and the power supply in the quotation.

Source: HQS Medical H820-II, H820-III, H880-IV and H890-V model specifications, checked against the manufacturer’s specification sheets. Follow each model link for its product specifications and enquiry options.