Introduction to 210V Warming System

The Veterinary Warming Blanket utilizes air convection to transmit heat generated by the main unit through a pipeline, ensuring even heat distribution for effective preservation or heating. This system is designed for the prevention and treatment of hypothermia in small animals, accelerating recovery and reducing hospitalization time.

Key Features of 210V

  • Utilizes the convection of air to transmit hot air generated by the main unit to the through the pipeline, so that the heat energy is evenly distributed and transmitted to the blanket to achieve heat preservation or heating effect.
  • For the prevention and treatment of hypothermia in small animals, it can accelerate the recovery of small animals and shorten the hospitalization time of small animals.
  • Quick Temperature Setting
  • 4 Temp.
  • Alarm volume 8 Level
  • Mute Time 2 minutes
  • History Record 10000pcs
  • Ambient Temperature Function Available
  • Language Chinese and English
  • Plasma air purification
  • 16 kinds disposable blankets optional
  • Filter G4 (EN779) grade
  • Class I Type of Protection against Electric Shock
  • Type BF protection against defibrillation discharge effects
  • Overheat Protection Function Dual hardware and software protection, real - time temperature monitoring and over 50± 5° C hardware forced power off protection
  • Multiple Wind Speed 8 adjustable wind speed can apply to different patients in different environments
  • Multiple Temperature Control Protection Dual hardware and software temperature protection
  • History Record More than 10,000 logs for necessary search
  • Air Purification Function With 0.25 μ 1 filter and plasma air purification function.
  • Reusable blankets size 120cm x 60cm
Share:

210V Warming System Specifications

PARAMETER
SPECIFICATION
Temperature Setting
32.0 ~ 41.0° C 、 95.0 ~ 105.8° F
Temperature Increment
0.1° C, 0.1° F
Temperature Deviation
<± 1° C, <± 1.8° F
Optional Unit
° C & ° F
Warming Up Time
<4 minutes
Working Mode
Continuous working
Operation Time
Real time display
Alarm
Overheat, low temperature, no operation, fan error, temperature sensor error
Power Consumption
850VA
Power Supply
AC220V, 50Hz/60Hz
Operation Environment
Temp: +10° C ~ +40° C; Humidity: 30% ~ 75%; Atmospheric pressure: non - condensation, 70KPa ~ 106Kpa
Storage Environment
Temperature: - 20° C ~ +55° C; Humidity: 10 ~ 93%; Atmospheric pressure: non - condensation, 50KPa ~ 106Kpa
Degree of Protection against Ingress of Liquid
IPX2
Dimension
260mm X 325mm X 325mm
Weight
<6Kg