Biological Safety Cabinet (Class II) BSC-1100B2, 1300B2, 1500B2, 1800B2 - Biological Safety Cabinet | HQS Medical
Biological Safety Cabinet

Biological Safety Cabinet (Class II)

Model: BSC-1100B2, 1300B2, 1500B2, 1800B2

Introduction to Biological Safety Cabinet (Class II)

The BSC-II Biological Safety Cabinet offers advanced protection for personnel, product, and the environment. It features a motorized front window, ULPA filtration with life indicators, automatic air speed adjustment, and a memory function for power failures. The work area is surrounded by negative pressure for maximum safety, and a comprehensive remote control system enhances ease of operation. Audio and visual alarms provide timely alerts for filter replacement, window height, and airflow anomalies.

Key Features of BSC-1100B2, 1300B2, 1500B2, 1800B2

  • Time reserve function
  • Automatic air speed adjustable with filter block
  • Memory function in case of power failure
  • Work area surrounded by negative pressure
  • Remote control for all functions
Share:

Biological Safety Cabinet (Class II) Specifications

MODEL
BSC-1100IIB2
BSC-1300IIB2
BSC-1500IIB2
BSC-1800IIB2
External Size (W*D*H) (mm)
1100*750*2250
1300*750*2250
1500*750*2250
1800*775*2250
Internal Size (W*D*H) (mm)
940*600*660
1150*600*660
1350*600*660
1625*600*660
Tested Opening Safety Height
200 mm (8")
200 mm (8")
200 mm (8")
200 mm (8")
Max Opening
420 mm (17")
420 mm (17")
500mm (20")
480mm (20")
Inflow Velocity
0.53± 0.025 m/s
0.53± 0.025 m/s
0.53± 0.025 m/s
0.53± 0.025 m/s
Downflow Velocity
0.33± 0.025 m/s
0.33± 0.025 m/s
0.33± 0.025 m/s
0.33± 0.025 m/s
ULPA Filter
Two, 99.999 5 % efficient at 0. 12 um. Filter life indicator.
Two, 99.999 5 % efficient at 0. 12 um. Filter life indicator.
Two, 99.999 5 % efficient at 0. 12 um. Filter life indicator.
Two, 99.999 5 % efficient at 0. 12 um. Filter life indicator.
Front Window
Motorized. Two - layer laminated toughened glass ≥ 6mm. Anti UV
Motorized. Two - layer laminated toughened glass ≥ 6mm. Anti UV
Motorized. Two - layer laminated toughened glass ≥ 6mm. Anti UV
Motorized. Two - layer laminated toughened glass ≥ 6mm. Anti UV
Noise
NSF49 ≤ 61dB / EN12469 ≤ 58 dB
NSF49 ≤ 61dB / EN12469 ≤ 58 dB
NSF49 ≤ 61dB / EN12469 ≤ 58 dB
NSF49 ≤ 61dB / EN12469 ≤ 58 dB
UV Lamp
30W*1
30 W*1
40W*1
40W*1
UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination.
-
-
-
-
Illuminating Lamp
12 W×2
12 W×2
16 W×2
16 W*2
Illumination
≥ 1000Lux
≥ 1000Lux
≥ 1000Lux
≥ 1000Lux
Consumption
800W
850W
1300W
1300W
Waterproof Socket
Two, total load of two sockets: 500W
Two, total load of two sockets: 500W
Two, total load of two sockets: 500W
Two, total load of two sockets: 500W
Display
LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc.
LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc.
LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc.
LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc.
Control System
Microprocessor
Microprocessor
Microprocessor
Microprocessor
Airflow System
0% air re-circulation, 100% air exhaust
0% air re-circulation, 100% air exhaust
0% air re-circulation, 100% air exhaust
0% air re-circulation, 100% air exhaust
Alarm
Abnormal airflow velocity; filter replacement; front window at unsafe height; high filter pressure alarm. Visual and Audio Alarm Filter replacement, window over height, abnormal air flow velocity.
Abnormal airflow velocity; filter replacement; front window at unsafe height; high filter pressure alarm. Visual and Audio Alarm Filter replacement, window over height, abnormal air flow velocity.
Abnormal airflow velocity; filter replacement; front window at unsafe height; high filter pressure alarm. Visual and Audio Alarm Filter replacement, window over height, abnormal air flow velocity.
Abnormal airflow velocity; filter replacement; front window at unsafe height; high filter pressure alarm. Visual and Audio Alarm Filter replacement, window over height, abnormal air flow velocity.
Exhaust Duct
4 meters PVC duct Diameter: 300mm
4 meters PVC duct Diameter: 300mm
4 meters PVC duct Diameter: 300mm
4 meters PVC duct Diameter: 300mm
Material Work Zone
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
Main Body
Cold-rolled steel with anti-bacteria powder coating.
Cold-rolled steel with anti-bacteria powder coating.
Cold-rolled steel with anti-bacteria powder coating.
Cold-rolled steel with anti-bacteria powder coating.
Work Surface Height
750mm (size can be customized according to requirements)
750mm (size can be customized according to requirements)
750mm (size can be customized according to requirements)
750mm (size can be customized according to requirements)
Caster
Footmaster caster
Footmaster caster
Footmaster caster
Footmaster caster
Power Supply
110/220V± 10%, 60/50Hz
110/220V± 10%, 60/50Hz
110/220V± 10%, 60/50Hz
110/220V± 10%, 60/50Hz (110V/60Hz is not applicable to ABS-1800IIB2)
Gross Weight
240 kg
280 kg
300 kg
408kg
Package (mm) Main Body (W*D*H)
1220*1000*1820
1460*1000*1820
1630*1000*1820
1930*1000*1820
Exhaust Blower (W*D*H)
970*810*630
970*810*630
970*810*630
970*810*680

Customer Reviews(0)

No reviews yet. Be the first to review this product!

Frequently Asked Questions (FAQ)

What are the key features of the Biological Safety Cabinet (Class II)?

The Biological Safety Cabinet (Class II) features Time reserve function, Automatic air speed adjustable with filter block, Memory function in case of power failure. It is designed for professional veterinary use and meets international quality standards.

What types of veterinary clinics is the Biological Safety Cabinet (Class II) suitable for?

The Biological Safety Cabinet (Class II) is suitable for small animal clinics, large animal hospitals, emergency veterinary centers, and specialty practices. It can be configured to meet different clinical requirements.

What is the warranty period for this equipment?

All HQS Medical veterinary equipment comes with a standard 12-24 months warranty and lifetime technical support.

Do you offer global shipping?

Yes, we provide fast and secure shipping to over 50 countries worldwide, including all necessary customs documentation.

Write a Review