Veterinary Blood Gas Analyzer BG-800 - Blood Gas Electrolyte Analyzer | HQS Medical
Blood Gas Electrolyte Analyzer

Veterinary Blood Gas Analyzer

Model: BG-800

Introduction to Veterinary Blood Gas Analyzer

The BG800 Veterinary Blood Gas Analyzer is designed for comprehensive analysis of whole blood, serum, and plasma. It offers rapid results with a quick analysis time and minimal sample volume, featuring automatic calibration and extensive data storage. The intuitive touchscreen interface and integrated printer enhance usability for veterinary professionals.

Key Features of BG-800

  • Analysis Time: <90s
  • Calibration: Automatic, programmable 1 - point and 2 - point calibration
  • Barcode Reader: Up to 14 kinds barcode type
  • Input Parameter Patient Temperature
  • FiO2
  • B. P.
  • TCP/IP Interface
  • USB Port
  • Integrated Bar - code Reader
Share:

Veterinary Blood Gas Analyzer Specifications

ANALYTE
MEASURING RANGE
UNIT
pH(CH)
6.000 - 9.000
pH scale
pCO2
0.667 - 26.67
KPa
pCO2
5.0 - 200.0
mmHg
pO2
0 - 106.7
KPa
pO2
0 - 800.0
mmHg
K+
0.50 - 10.00
mmol/L
Na+
50.0 - 200.0
mmol/L
Cl+
20.0 - 200.0
mmol/L
Ca++
0.10 - 5.00
mmol/L
Hct
12.0 - 65.0
%
B.P.
500 - 800
mmHg
Glucose
1.1 - 66.7
mmol/L
Lactate
0.4 - 30.0
mmol/L
pH(TC)
pH temperature corrected
-
pCO2(TC)
pCO2 temperature corrected
-
pO2(TC)
pO2 temperature corrected
-
TCO2
Total carbon dioxide
-
HCO3
Actual plasma bicarbonate
-
BEb
Base Excess in blood
-
BEecf
Base Excess in extra cellular fluids
-
SBC
Standard bicarbonate
-
sO2%
Calculated oxygen saturation percentage
-
Ca++(7.4)
Ionized calcium ” normalized ” to pH7.4
-
TCa
Total calcium content
-
AG
Anion gap
-
RI
Respiratory index
-
AaDO2
Alveolar artillery oxygen gradient
-
O2SAT
Oxygen Saturation
-
tHb(c)
Hemoglobin (Calculated)
-
Dimension Instrument
400(W)mm*574(H)mm*344(D)mm
-
CAL PAK
258(W)mm*180(H)mm*70(D)mm
-
AUTOQC
103(W)mm*180(H)mm*70(D)mm
-
Weight
18KGS
-
Working temperature
15° C ~ 30° C
-
Storage environment
5° C ~ 45° C
-
Power supply
100 - 240V ~ 50 /60 Hz
-

Buyer decision support

BG-800 procurement decision notes

The analyzer family has different assay menus, so the exact BG-800 variant, sample type, consumables and quality-control workflow must be fixed in the quotation.

Decision factorPublished for this modelConfirm before order
Base BG-800 menupH, pCO₂, pO₂, K⁺, Na⁺, Cl⁻, Ca²⁺ and Hct listedConfirm the delivered model suffix and obtain the signed analyte menu; do not infer BG-800E glucose/lactate capability for BG-800.
Sample volume95 µL whole blood; 120 µL when glucose/lactate are included; 50 µL capillary bloodConfirm which volume applies to the selected variant, sample container and test panel.
Analysis and storage<90 seconds analysis and >10,000-result storage listedConfirm startup, calibration and maintenance time as well as result-export and data-backup methods.
Calibration and QCAutomatic programmable one-point and two-point calibrationList CAL PAK, AUTOQC, controls, replacement intervals, shelf life and storage requirements.
InterfacesRS-232, TCP/IP, USB and integrated barcode readerRequest the communication protocol and verify compatibility with the intended practice or laboratory system.

Published-data limitations

  • The public specification table includes glucose and lactate ranges even though the brochure assigns them to the BG-800E menu; this conflict must remain visible until confirmed.
  • Precision, linearity, method comparison, interference and species-validation evidence are not supplied in the model brochure.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: BG800 Veterinary Blood Gas Analyzer model brochure (3 pages). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Visitor Reviews(0)

Submissions are moderated for spam. Purchase status is not independently verified.

No reviews yet. Be the first to review this product!

Write a Review

Submit only first-hand feedback. AI-generated, copied or incentivized reviews are not accepted.