The BG800 Veterinary Blood Gas Analyzer is designed for comprehensive analysis of whole blood, serum, and plasma. It offers rapid results with a quick analysis time and minimal sample volume, featuring automatic calibration and extensive data storage. The intuitive touchscreen interface and integrated printer enhance usability for veterinary professionals.
Key Features of BG-800
- Analysis Time: <90s
- Calibration: Automatic, programmable 1 - point and 2 - point calibration
- Barcode Reader: Up to 14 kinds barcode type
- Input Parameter Patient Temperature
- FiO2
- B. P.
- TCP/IP Interface
- USB Port
- Integrated Bar - code Reader
Veterinary Blood Gas Analyzer Specifications
ANALYTE | MEASURING RANGE | UNIT |
|---|---|---|
pH(CH) | 6.000 - 9.000 | pH scale |
pCO2 | 0.667 - 26.67 | KPa |
pCO2 | 5.0 - 200.0 | mmHg |
pO2 | 0 - 106.7 | KPa |
pO2 | 0 - 800.0 | mmHg |
K+ | 0.50 - 10.00 | mmol/L |
Na+ | 50.0 - 200.0 | mmol/L |
Cl+ | 20.0 - 200.0 | mmol/L |
Ca++ | 0.10 - 5.00 | mmol/L |
Hct | 12.0 - 65.0 | % |
B.P. | 500 - 800 | mmHg |
Glucose | 1.1 - 66.7 | mmol/L |
Lactate | 0.4 - 30.0 | mmol/L |
pH(TC) | pH temperature corrected | - |
pCO2(TC) | pCO2 temperature corrected | - |
pO2(TC) | pO2 temperature corrected | - |
TCO2 | Total carbon dioxide | - |
HCO3 | Actual plasma bicarbonate | - |
BEb | Base Excess in blood | - |
BEecf | Base Excess in extra cellular fluids | - |
SBC | Standard bicarbonate | - |
sO2% | Calculated oxygen saturation percentage | - |
Ca++(7.4) | Ionized calcium ” normalized ” to pH7.4 | - |
TCa | Total calcium content | - |
AG | Anion gap | - |
RI | Respiratory index | - |
AaDO2 | Alveolar artillery oxygen gradient | - |
O2SAT | Oxygen Saturation | - |
tHb(c) | Hemoglobin (Calculated) | - |
Dimension Instrument | 400(W)mm*574(H)mm*344(D)mm | - |
CAL PAK | 258(W)mm*180(H)mm*70(D)mm | - |
AUTOQC | 103(W)mm*180(H)mm*70(D)mm | - |
Weight | 18KGS | - |
Working temperature | 15° C ~ 30° C | - |
Storage environment | 5° C ~ 45° C | - |
Power supply | 100 - 240V ~ 50 /60 Hz | - |
Buyer decision support
BG-800 procurement decision notes
The analyzer family has different assay menus, so the exact BG-800 variant, sample type, consumables and quality-control workflow must be fixed in the quotation.
| Decision factor | Published for this model | Confirm before order |
|---|---|---|
| Base BG-800 menu | pH, pCO₂, pO₂, K⁺, Na⁺, Cl⁻, Ca²⁺ and Hct listed | Confirm the delivered model suffix and obtain the signed analyte menu; do not infer BG-800E glucose/lactate capability for BG-800. |
| Sample volume | 95 µL whole blood; 120 µL when glucose/lactate are included; 50 µL capillary blood | Confirm which volume applies to the selected variant, sample container and test panel. |
| Analysis and storage | <90 seconds analysis and >10,000-result storage listed | Confirm startup, calibration and maintenance time as well as result-export and data-backup methods. |
| Calibration and QC | Automatic programmable one-point and two-point calibration | List CAL PAK, AUTOQC, controls, replacement intervals, shelf life and storage requirements. |
| Interfaces | RS-232, TCP/IP, USB and integrated barcode reader | Request the communication protocol and verify compatibility with the intended practice or laboratory system. |
Published-data limitations
- The public specification table includes glucose and lactate ranges even though the brochure assigns them to the BG-800E menu; this conflict must remain visible until confirmed.
- Precision, linearity, method comparison, interference and species-validation evidence are not supplied in the model brochure.
Prepared by HQS Medical Product Team · Documentation reviewed:
Source: BG800 Veterinary Blood Gas Analyzer model brochure (3 pages). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.
Visitor Reviews(0)
Submissions are moderated for spam. Purchase status is not independently verified.
Related Products
Write a Review
Submit only first-hand feedback. AI-generated, copied or incentivized reviews are not accepted.