Blood Gas&Immunoflurescence Analyzer
Veterinary Blood Gas & Immunoassay Analyzer HBI-G2
Model: HBI-G2
Introduction — Veterinary Blood Gas & Immunoassay Analyzer
The HBI-G2 analyzer is a versatile veterinary diagnostic device that integrates fluorescence immunoassay, blood gas, and electrolyte analysis into a single, portable unit. Delivering laboratory-quality results in 4-10 minutes, it supports disease diagnosis, immune status assessment, pre- and post-operative monitoring, and critical care for canines and felines.
Key Features — HBI-G2
- Combines fluorescence immunoassay and blood gas & electrolyte platforms in one device
- Up to 28 immunoassay parameters and 12 blood gas parameters
- Fully automated system requiring no special operator training
- Testing performed in several simple steps
- Simultaneous testing of immunoassay and blood gas & electrolyte
- Test results available in 4-10 minutes
- Streamlines patient-testing workflow
- Advanced electrode technology for blood gas analysis
- Rare-earth nanocrystal biological probes for stable, accurate, and sensitive results
- Automatic calibration ensures instrument measurement accuracy
Get the price list by email
Share:
Veterinary Blood Gas & Immunoassay Analyzer Specifications
PARAMETERS | SPECIFICATIONS |
|---|---|
Sample Type | Whole blood, serum, plasma, secretion etc. |
Sample Volume | 100 μL |
Methodology | Fluorescence immunochromatographic assay; Blood gas electrochemical technology |
Test time | 4 - 10 minutes |
QC & Calibration | Real-time full-auto finish |
Display | 7 inch 800*480px |
Storage | MAX 500,000 |
Rated Power | 36VA |
DC connector | DC 5.5 |
Power Supply | 12V 3A |
Connectors | 4 USB ports, 1 LAN port |
Dimension | 240mm*200mm*135mm |
Net Weight | 2 KG |
Printer | Built-in thermal printer |
Operating Environment | Operating temperature: 5 - 32° C; Humidity ≤ 85%; Keep away from strong Electromagnetic interference sources |
Warranty and after-sales service for HBI-G2
How HQS handles warranty, spare parts and repairs for this model.
- Warranty period
- The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
- What is covered
- A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
- Spare parts
- Spare parts and technical support are available for at least eight years from the date HQS ships the product.
- Response time
- Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
- Repairs in warranty
- If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
- Repairs after warranty
- HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.