Vet Handheld Pulse Oximeter
Introduction to Vet Handheld Pulse Oximeter
The Vet H-M2 veterinary handheld pulse oximeter utilizes photoelectric oxyhemoglobin inspection technology and capacity pulse scanning & recording technology to measure SpO2 and pulse rate in animals via their tongue or ear.
Key Features of H-M2
- Stylish and exquisite appearance
- Small size, easy to carry
- Compatible software for data analysis
- Real-time display of values and waveforms
- Support multiple languages
- Digital oximetry technology, anti-motion interference
- Strong resistance to weak perfusion
- Suitable for use at home, pet hospitals, etc.
- Rechargeable lithium battery, 10 hours continuous working (Single blood oxygen)
- With audible, text and visual alarms, three levels of alarms
Vet Handheld Pulse Oximeter Specifications
PARAMETER | SPECIFICATION |
|---|---|
Application range | Cat/Dog/Horse/Medicine/Surgery/Operating Room |
SpO2 Measurement range | 70~99% |
Accuracy | 70%~99%: ± 2 digits; 0%~69% no definition |
Resolution | 1% |
Pulse Rate Measure range | 18 - 300 bpm |
Accuracy | ± 3bpm or ± 3% |
Resolution | 1bpm |
Temperature Measure range | 0~50° C |
Accuracy | ± 0.1 ° C |
Resolution | 0.1 ° C |
Power Requirements Lithium Battery capacity | 3100mAh |
Charging time | 8 hours |
Working time | 10 hours(Single blood oxygen) |
Dimension | 81.7mm*27.9mm*152.2mm |
Environment requirements OperationTemperature | 5~4 ° C |
Storage Temperature | - 20~+55 ° C |
Ambient Humidity | ≤ 80% no condensation in operation ≤ 93% no condensation in storage |
Atmosphere pressure | 86kPa - 106kPa |
Buyer decision support
H-M2 procurement decision notes
Probe fit, species/measurement-site performance, low-perfusion behavior and alarm configuration matter more than the display specification alone.
| Decision factor | Published for this model | Confirm before order |
|---|---|---|
| SpO₂ range | 70–99%; accuracy listed as ±2 digits from 70–99%, undefined below 70% | Request the validation method, applicable species, perfusion conditions and exact animal probe supplied. |
| Pulse rate | 18–300 bpm; accuracy ±3 bpm or ±3% | Confirm which accuracy rule applies and review performance under motion and weak perfusion. |
| Measurement sites | Tongue or ear measurement described | Confirm sensor dimensions and suitability for the animal sizes and sites used by the clinic. |
| Power | 3,100 mAh battery, 8-hour charge and 10-hour single-SpO₂ operation listed | Confirm battery test conditions, replacement availability and charging accessories. |
| Temperature function | 0–50 °C measurement range with 0.1 °C resolution listed | Confirm whether the temperature probe/function is included and its intended measurement method. |
Published-data limitations
- The brochure’s operating-temperature entry reads “5~4 °C” and is not usable until corrected by the supplier.
- The brochure does not provide species-specific accuracy, motion/perfusion test data or alarm-default documentation.
Prepared by HQS Medical Product Team · Documentation reviewed:
Source: H-M2 Vet Handheld Pulse Oximeter model brochure (2 pages). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.
Visitor Reviews(0)
Submissions are moderated for spam. Purchase status is not independently verified.
Related Products
Write a Review
Submit only first-hand feedback. AI-generated, copied or incentivized reviews are not accepted.