Vet Handheld Pulse Oximeter H-M2 - Pulse Oximeter | HQS Medical
Pulse Oximeter

Vet Handheld Pulse Oximeter

Model: H-M2

Introduction to Vet Handheld Pulse Oximeter

The Vet H-M2 veterinary handheld pulse oximeter utilizes photoelectric oxyhemoglobin inspection technology and capacity pulse scanning & recording technology to measure SpO2 and pulse rate in animals via their tongue or ear.

Key Features of H-M2

  • Stylish and exquisite appearance
  • Small size, easy to carry
  • Compatible software for data analysis
  • Real-time display of values and waveforms
  • Support multiple languages
  • Digital oximetry technology, anti-motion interference
  • Strong resistance to weak perfusion
  • Suitable for use at home, pet hospitals, etc.
  • Rechargeable lithium battery, 10 hours continuous working (Single blood oxygen)
  • With audible, text and visual alarms, three levels of alarms
Share:

Vet Handheld Pulse Oximeter Specifications

PARAMETER
SPECIFICATION
Application range
Cat/Dog/Horse/Medicine/Surgery/Operating Room
SpO2 Measurement range
70~99%
Accuracy
70%~99%: ± 2 digits; 0%~69% no definition
Resolution
1%
Pulse Rate Measure range
18 - 300 bpm
Accuracy
± 3bpm or ± 3%
Resolution
1bpm
Temperature Measure range
0~50° C
Accuracy
± 0.1 ° C
Resolution
0.1 ° C
Power Requirements Lithium Battery capacity
3100mAh
Charging time
8 hours
Working time
10 hours(Single blood oxygen)
Dimension
81.7mm*27.9mm*152.2mm
Environment requirements OperationTemperature
5~4 ° C
Storage Temperature
- 20~+55 ° C
Ambient Humidity
≤ 80% no condensation in operation ≤ 93% no condensation in storage
Atmosphere pressure
86kPa - 106kPa

Buyer decision support

H-M2 procurement decision notes

Probe fit, species/measurement-site performance, low-perfusion behavior and alarm configuration matter more than the display specification alone.

Decision factorPublished for this modelConfirm before order
SpO₂ range70–99%; accuracy listed as ±2 digits from 70–99%, undefined below 70%Request the validation method, applicable species, perfusion conditions and exact animal probe supplied.
Pulse rate18–300 bpm; accuracy ±3 bpm or ±3%Confirm which accuracy rule applies and review performance under motion and weak perfusion.
Measurement sitesTongue or ear measurement describedConfirm sensor dimensions and suitability for the animal sizes and sites used by the clinic.
Power3,100 mAh battery, 8-hour charge and 10-hour single-SpO₂ operation listedConfirm battery test conditions, replacement availability and charging accessories.
Temperature function0–50 °C measurement range with 0.1 °C resolution listedConfirm whether the temperature probe/function is included and its intended measurement method.

Published-data limitations

  • The brochure’s operating-temperature entry reads “5~4 °C” and is not usable until corrected by the supplier.
  • The brochure does not provide species-specific accuracy, motion/perfusion test data or alarm-default documentation.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: H-M2 Vet Handheld Pulse Oximeter model brochure (2 pages). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Visitor Reviews(0)

Submissions are moderated for spam. Purchase status is not independently verified.

No reviews yet. Be the first to review this product!

Write a Review

Submit only first-hand feedback. AI-generated, copied or incentivized reviews are not accepted.