Table Type Pulse Vacuum Steam Sterilizer T45/T60/T80 - Pulse Vacuum Table Type | HQS Medical
Pulse Vacuum Table Type

Table Type Pulse Vacuum Steam Sterilizer T45/T60/T80

Model: T45/T60/T80

Introduction — Table Type Pulse Vacuum Steam Sterilizer

The T45/T60/T80 is a Class B tabletop steam sterilizer designed for efficient, safe, and economical sterilization of various medical instruments and materials. Utilizing steam as its sterilization medium, it is commonly used in dental, ophthalmological, operating rooms, and CSSD departments for sterilizing warped or unwrapped instruments, fabrics, utensils, culture media, and unsealed liquids.

Key Features — T45/T60/T80

  • Built-in open-type water tank for easy cleaning and continuous operation with water level and quality monitoring.
  • Brand-new LCD screen displaying temperature, pressure, time, running process, error, and alarm information.
  • Multiple safety protection devices including over-temperature protection, steam generator control, door safety interlock, dual chamber over-pressure protection, and electronic circuit safety.
  • Automatic door structure for fast and simple operation, protecting operators from scald (VC-45L).
  • Multi-point synchronous linkage pressing technology for reliable and durable door operation (VC-60L/80L).
  • Efficient vacuum system with low working noise, achieving a vacuum limit below -90kPa for high-speed vacuum and perfect drying performance.
  • Efficient steam generator (instant for VC-45L, energy-storage for VC-60L/80L) producing steam quickly and in good quantity.
  • Pulse vacuum, heating, sterilization, exhausting, and vacuum drying are fully automatic processes.
  • Chamber heating by film heater for energy and time saving.
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for T45/T60/T80

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

T45/T60/T80 Table Type Pulse Vacuum Steam Sterilizer product datasheet

Public PDF

HQS datasheet for the T45/T60/T80: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
T45/T60/T80
Length
2 pages
File
PDF · 244 KB
Web copy prepared
Need a different language or configuration-specific document?

Table Type Pulse Vacuum Steam Sterilizer Specifications

PARAMETER
T45
T60
T80
Temperature Range
105 ℃ - 138 ℃
105 ℃ - 138 ℃
105 ℃ - 138 ℃
Design pressure
-0.1/ 0.3Mpa
-0.1/ 0.3Mpa
-0.1/ 0.3Mpa
Design Temperature
144 ℃
144 ℃
144 ℃
Chamber dimension(⌀ *L) mm
316*618
358*595
358*717
Overall dimension WxDxH (mm)
830*640*550
1002*730*560
1002*730*560
Net weight
115kg
160kg
180kg
Input Power (KVW)
5.8
7.4
7.4
Power
1 Φ 220V 50Hz
1 Φ 220V 50Hz
1 Φ 220V 50Hz

Configuration

  • Unwrapped program
  • Wrapped program
  • Rubber program
  • User01 program
  • N-Quick program
  • B-Quick program
  • Prion program
  • BD & Helix program
  • Leak Test program
  • Preheat auxiliary program
  • Drying auxiliary program
  • Washing auxiliary program

Buyer decision support

T45/T60/T80 tabletop pulse vacuum steam sterilizer procurement decision notes

The T45, T60 and T80 are HQS tabletop pulse vacuum steam sterilizers for wrapped and unwrapped instruments, textiles, utensils, culture media and unsealed liquids. The cycle — pulse vacuum, heating, sterilization, exhaust and vacuum drying — runs automatically, with a vacuum lower limit beyond −90 kPa for air removal and drying. Programs include Unwrapped, Wrapped, Rubber, User01, N-Quick, B-Quick and Prion, test programs BD & Helix and Leak Test, and auxiliary Preheat, Drying and Washing programs. All three work from 105 to 138 °C (design pressure −0.1/0.3 MPa, design temperature 144 °C) on single-phase 220 V, 50 Hz, with a built-in open water tank that is monitored for level and quality, an LCD that shows temperature, pressure, time, cycle stage and alarms, and protection including door interlock and dual chamber over-pressure protection. How to choose in the series: the T45 (chamber Φ316 × 618 mm, 830 × 640 × 550 mm, 115 kg, 5.8 kW) has an automatic door and an instant steam generator; the T60 (Φ358 × 595 mm) and T80 (Φ358 × 717 mm) share a 1002 × 730 × 560 mm body and 7.4 kW input, weigh 160 kg and 180 kg, and use an energy-storage steam generator with a multi-point linkage door. Pick by chamber length and check the bench can carry the weight.

Decision factorPublished for this modelConfirm before order
Chamber and sizeT45: chamber Φ316 × 618 mm, 830 × 640 × 550 mm, 115 kg. T60: Φ358 × 595 mm, 1002 × 730 × 560 mm, 160 kg. T80: Φ358 × 717 mm, 1002 × 730 × 560 mm, 180 kgTell us your largest trays and packs, and confirm the bench or stand can carry the net weight.
Sterilization range105–138 °C; design pressure −0.1/0.3 MPa; design temperature 144 °C; vacuum lower limit beyond −90 kPaAsk for cycle times of the programs you will use most.
ProgramsUnwrapped, Wrapped, Rubber, User01, N-Quick, B-Quick, Prion; test: BD & Helix, Leak Test; auxiliary: Preheat, Drying, WashingConfirm whether BD and Helix test packs are included or must be ordered separately.
Steam and waterT45: built-in instant steam generator; T60/T80: built-in energy-storage steam generator; open water tank with water level and quality monitoringAsk for the water quality required and the tank capacity.
Power and safetySingle-phase 220 V, 50 Hz; input power 5.8 kW (T45), 7.4 kW (T60, T80); over-temperature protection, steam generator protection, door safety interlock, dual chamber over-pressure protection; T45 automatic door, T60/T80 multi-point synchronous linkage doorConfirm your installation circuit can supply 5.8–7.4 kW.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: T45/T60/T80 Table Type Pulse Vacuum Steam Sterilizer model brochure. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for T45/T60/T80

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →