Pet ICU Incubator
Introduction to Pet ICU Incubator
The H-1805 Pet ICU Incubator is designed for warming and caring for post-operative animals, animals requiring infusion, and newborn puppies and kittens. It enhances animal comfort and provides a reassuring sensory experience for pet owners.
Key Features of H-1805
- Adjustable temperature, humidity, and oxygen connection
- Real-time monitoring of temperature, humidity, O2 concentration, and nebulization
- Integrated 10-stage amber lighting
- UV disinfection lamp for sterilization
- High concentration of negative ions
- Visible index display window
- External nebulizer
- External humidifier
- O2 monitoring
Pet ICU Incubator Specifications
Specification | Value |
|---|---|
Input power | ≤ 400VA |
Ambient temperature | 10° C ~ 35° C |
Cabinet temperature control range | 15° C ~ 38° C (can be up to 39° C by special operations) |
Temperature fluctuation | ≤ 0.8 ° C |
Average temperature of monitoring chamber | ≤ 1.0 ° C |
Cabinet temperature control accuracy | ≤± 0.5 ° C |
Temperature rise time | 5 ~ 20min |
Noises in monitoring room | ≤ 30dB |
Product size | 88*55*47cm |
Buyer decision support
H-1805 procurement decision notes
Confirm environmental control, oxygen-source compatibility, cleaning workflow and sensor support before treating an incubator quotation as complete.
| Decision factor | Published for this model | Confirm before order |
|---|---|---|
| Temperature control | 15–38 °C; up to 39 °C by special operation | Confirm set-point limits, alarm behavior and calibration procedure in the current manual. |
| Published accuracy | Control accuracy ≤ ±0.5 °C | Request calibration documentation and the recommended verification interval. |
| Environmental monitoring | Temperature, humidity and O₂ concentration listed | Confirm sensor ranges, replacement parts and whether calibration tools are included. |
| Oxygen and nebulization | Oxygen connection and nebulization listed | Confirm connector standard, source pressure and compatible nebulizer components. |
| Power | Input power ≤ 400 VA | Confirm destination voltage/frequency and backup-power requirements. |
Published-data limitations
- The incubator does not replace clinical monitoring or a veterinarian-defined oxygen and temperature protocol.
- Confirm the exact disinfectant compatibility and UV-lamp safety procedure before purchase.
Prepared by HQS Medical Product Team · Documentation reviewed:
Source: H-1805 Pet ICU Incubator model brochure (1 page). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.
Visitor Reviews(0)
Submissions are moderated for spam. Purchase status is not independently verified.
Related Products
Write a Review
Submit only first-hand feedback. AI-generated, copied or incentivized reviews are not accepted.