Pet ICU Incubator H-1805 - Vet ICU Incubator | HQS Medical
Vet ICU Incubator

Pet ICU Incubator

Model: H-1805

Introduction to Pet ICU Incubator

The H-1805 Pet ICU Incubator is designed for warming and caring for post-operative animals, animals requiring infusion, and newborn puppies and kittens. It enhances animal comfort and provides a reassuring sensory experience for pet owners.

Key Features of H-1805

  • Adjustable temperature, humidity, and oxygen connection
  • Real-time monitoring of temperature, humidity, O2 concentration, and nebulization
  • Integrated 10-stage amber lighting
  • UV disinfection lamp for sterilization
  • High concentration of negative ions
  • Visible index display window
  • External nebulizer
  • External humidifier
  • O2 monitoring
Share:

Pet ICU Incubator Specifications

Specification
Value
Input power
≤ 400VA
Ambient temperature
10° C ~ 35° C
Cabinet temperature control range
15° C ~ 38° C (can be up to 39° C by special operations)
Temperature fluctuation
≤ 0.8 ° C
Average temperature of monitoring chamber
≤ 1.0 ° C
Cabinet temperature control accuracy
≤± 0.5 ° C
Temperature rise time
5 ~ 20min
Noises in monitoring room
≤ 30dB
Product size
88*55*47cm

Buyer decision support

H-1805 procurement decision notes

Confirm environmental control, oxygen-source compatibility, cleaning workflow and sensor support before treating an incubator quotation as complete.

Decision factorPublished for this modelConfirm before order
Temperature control15–38 °C; up to 39 °C by special operationConfirm set-point limits, alarm behavior and calibration procedure in the current manual.
Published accuracyControl accuracy ≤ ±0.5 °CRequest calibration documentation and the recommended verification interval.
Environmental monitoringTemperature, humidity and O₂ concentration listedConfirm sensor ranges, replacement parts and whether calibration tools are included.
Oxygen and nebulizationOxygen connection and nebulization listedConfirm connector standard, source pressure and compatible nebulizer components.
PowerInput power ≤ 400 VAConfirm destination voltage/frequency and backup-power requirements.

Published-data limitations

  • The incubator does not replace clinical monitoring or a veterinarian-defined oxygen and temperature protocol.
  • Confirm the exact disinfectant compatibility and UV-lamp safety procedure before purchase.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: H-1805 Pet ICU Incubator model brochure (1 page). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Visitor Reviews(0)

Submissions are moderated for spam. Purchase status is not independently verified.

No reviews yet. Be the first to review this product!

Write a Review

Submit only first-hand feedback. AI-generated, copied or incentivized reviews are not accepted.