Medical Pharmacy Refrigerator RF-V60G - Refrigerator | HQS Medical
Refrigerator

Medical Pharmacy Refrigerator RF-V60G

Model: RF-V60G

Introduction — Medical Pharmacy Refrigerator

The RF-V60G Medical Pharmacy Refrigerator is designed for accurate and reliable temperature control, maintaining an internal temperature range of 2~8°C with an accuracy of 0.1°C. It features a specially designed forced-air cooling system for frost-free operation and excellent temperature uniformity, along with a double-layer hollow insulation LOW-E glass door to prevent condensation. Safety features include keyboard locking, password protection, a built-in backup battery for alarms, and multiple visual and audible alarms for various conditions.

Key Features — RF-V60G

  • Specially designed forced-air cooling system, circulating air cold back blowing technology, ensure frost - free cabinet and good temperature uniformity
  • Double - layer hollow insulation LOW - E glass door, use light reflection to prevent condensation
  • Cold spray steel plate inner chamber for friendly using and easy cleaning
  • Keyboard locking, password protection function, to prevent unauthorized access adjustment of operating parameters
  • Auto on/off cooling fan to prevent cold air from leaking out when the door is opening
  • Visual and audible alarms: high/low temperature, power failure, thermostat failure, door ajar, 4 visual and audible alarms
  • Power failure protection: turn on delay of the cooling system after power failure
  • 4 adjustable bottom foot design for easy adjustment of height and fixation
  • 2 adjustable steel wire impregnated plastic shelf for easy storing
  • Special designed service - free drainage system ensure no water in the cabinet
  • Auto on/off LED light with manual switch on control panel
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for RF-V60G

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

RF-V60G Medical Pharmacy Refrigerator product datasheet

Public PDF

HQS datasheet for the RF-V60G: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
RF-V60G
Length
2 pages
File
PDF · 249 KB
Web copy prepared
Need a different language or configuration-specific document?

Medical Pharmacy Refrigerator Specifications

Specification
Value
Capacity
60L
Temperature range
2~8 ℃
Ambient temperature
10~32 ℃
Controller
Microprocessor
Display
Digital display
Compressor
1
Refrigerant
R600a
Cooling type
Forced - air cooling
Defrost type
Frost free
Power supply
220V 50~60Hz; 115V 60Hz
Rated power
72W
Electrical current
0.59A
Power consumption
0.84kWh/24h
Interior size (W*D*H)
410*315*560mm
Exterior size (W*D*H)
495*450*710mm
Package size (W*D*H)
558*510*760mm
NW/GW
33/37KGS
Loading quantity (20’/40’/40’H)
132/276/276

Compare models in this series

Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.

This model belongs to the RF-V316 series. The series overview lists every model side by side. Open series overview

ParameterRF-V60GThis modelRF-V226RF-V316RF-V1006
Capacity60L226L316 L1006L
Temperature range2~8 ℃2~8° C2–8 °C2~8 ℃
Ambient temperature10~32 ℃10~32° C—10~32 ℃
RefrigerantR600aR600a—R290
Defrost typeFrost freeAuto defrost—Frost free
Power supply220V 50~60Hz; 115V 60Hz220V ~240V/ 50~60Hz; 115V / 60Hz—220V 50~60Hz; 115V 60Hz
Rated power72W140 W—472W
Electrical current0.59A1.0 A—2.71A
Power consumption0.84kWh/24h1.6kWh/24h—4.82kWh/24h
Interior size (W*D*H)410*315*560mm534 * 406 * 1150 mm—1100*684*1325mm
Exterior size (W*D*H)495*450*710mm625 * 594 * 1707 mm—1220*872*1885mm
Package size (W*D*H)558*510*760mm707 * 676 * 1820 mm—1330*950*2000mm
NW/GW33/37KGS73 / 76 kg—189/213KGS
Loading quantity (20’/40’/40’H)132/276/27624 / 51 / 51—8/18/18

Configuration

  • Lamp: LED

Buyer decision support

RF-V60G pharmacy refrigerator procurement decision notes

The RF-V60G is a 60-litre compact 2–8 °C pharmacy refrigerator for a consulting room, treatment area or small clinic pharmacy. Its microprocessor controller holds the cabinet at 2–8 °C with 0.1 °C accuracy, and frost-free forced-air cooling with cold air blown back across the cabinet keeps the temperature even. The door is double-layer hollow LOW-E glass to prevent condensation. A built-in backup battery keeps the temperature display and the audible and visual alarms working for up to 8 hours without mains power; the four alarms are high/low temperature, power failure, thermostat failure and door ajar. A keyboard lock with password protects the settings, and if the controller or both sensors fail the cooling keeps running on its remembered cycle. It runs on 220 V, 50–60 Hz or 115 V, 60 Hz, rated 72 W and 0.84 kWh per 24 h, in rooms from 10 to 32 °C. Exterior size is 495 × 450 × 710 mm, 33 kg, with two shelves and a 25 mm test hole for a temperature recorder. For more storage, compare the 226-litre RF-V226, which also has a 48-hour alarm backup.

Decision factorPublished for this modelConfirm before order
Capacity and temperature60 L; 2–8 °C with 0.1 °C accuracy; suggested ambient 10–32 °CTell us the room temperature range where it will stand.
CoolingForced-air cooling with cold air back-blowing; frost free; 1 compressor; R600a refrigerant; cooling fan stops when the door opensAsk for the pull-down time from room temperature to 2–8 °C.
Alarms and protection4 audible and visual alarms: high/low temperature, power failure, thermostat failure, door ajar; backup battery runs display and alarms up to 8 h without AC power; delayed restart after power failure; cooling continues on memory if the controller or two sensors fail; keyboard lock with passwordIf you need recorded temperature data, ask which recorder fits the 25 mm test hole.
Power220 V, 50–60 Hz or 115 V, 60 Hz; wide voltage range 187–242 V; rated power 72 W; 0.59 A; 0.84 kWh/24 hState your mains voltage so the matching version is supplied.
Size and fittingsInterior 410 × 315 × 560 mm; exterior 495 × 450 × 710 mm; package 558 × 510 × 760 mm; 33/37 kg; 4 adjustable feet, 2 plastic-coated wire shelves, LED light, test hole 25 mm; 132/276/276 per 20'/40'/40'H containerCheck the space and ventilation around the cabinet.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: RF-V60G Medical Pharmacy Refrigerator model brochure. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for RF-V60G

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →