Water Purifier HWP-IV - Water Purifier | HQS Medical
Water Purifier

Water Purifier HWP-IV

Model: HWP-IV

Introduction — Water Purifier

The HWP - IV Water Purifier is designed for efficient water purification, featuring a large LED display that shows all running states and parameters. It includes automatic RO membrane cleaning, high/low pressure protection, and alarm functions for water quality, low water, full water, and consumable life ending, along with automatic diagnosis.

Key Features — HWP-IV

  • Large LED display, show all the running state and parameters.
  • RO membrane clean automatically.
  • High/Low pressure protection.
  • Alarm function: Water quality, no water, full water, consumables life ending.
  • Automatic diagnosis.
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for HWP-IV

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

HWP-IV Water Purifier product datasheet

Public PDF

HQS datasheet for the HWP-IV: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
HWP-IV
Length
2 pages
File
PDF · 203 KB
Web copy prepared
Need a different language or configuration-specific document?

Water Purifier Specifications

MODEL
HWP - IV 45
HWP - IV 63
HWP - IV 94
HWP - IV 125
W ater Output Type
R O water
RO water
RO water
RO water
W ater Output Speed
45L/H
63L/H
94L/H
125L/H
Flow procedure
PF+AC+AC+RO
PF+AC+AC+RO
PF+AC+AC+RO
PF+AC+AC+RO
Water Supply Requirement
T ap water: TDS<200 ppm, 5~45° C, 1.0 - 4.0Kgf/cm2 (if TDS>200ppm, extra pretreatment filter is recommended)
T ap water: TDS<200 ppm, 5~45° C, 1.0 - 4.0Kgf/cm2 (if TDS>200ppm, extra pretreatment filter is recommended)
T ap water: TDS<200 ppm, 5~45° C, 1.0 - 4.0Kgf/cm2 (if TDS>200ppm, extra pretreatment filter is recommended)
T ap water: TDS<200 ppm, 5~45° C, 1.0 - 4.0Kgf/cm2 (if TDS>200ppm, extra pretreatment filter is recommended)
Purificatio n system Pretreatment unit
20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1
20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1
20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1
20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1
RO unit
300 GPD RO membrane× 1
400 GPD RO membrane× 1
600 GPD RO membrane× 1
400 GPD RO membrane× 2
Pure water quality Ion rejection rate
97%~99% (New RO membrane)
97%~99% (New RO membrane)
97%~99% (New RO membrane)
97%~99% (New RO membrane)
Organic rejection rate
> 99%,when MW > 200 Dalton
> 99%,when MW > 200 Dalton
> 99%,when MW > 200 Dalton
> 99%,when MW > 200 Dalton
Particles and bacteria rejection rate
>99%
>99%
>99%
>99%
Bacteria
<0.01cfu/ml (with optional 0.2 μ m PES terminal filter)
<0.01cfu/ml (with optional 0.2 μ m PES terminal filter)
<0.01cfu/ml (with optional 0.2 μ m PES terminal filter)
<0.01cfu/ml (with optional 0.2 μ m PES terminal filter)
Particles (>0.2 μm)
<1/ml (with optional 0.2 μ m PES terminal filter)
<1/ml (with optional 0.2 μ m PES terminal filter)
<1/ml (with optional 0.2 μ m PES terminal filter)
<1/ml (with optional 0.2 μ m PES terminal filter)
Water Quality Monitor
TDS/conductivity test pen
TDS/conductivity test pen
TDS/conductivity test pen
TDS/conductivity test pen
Consumption
120W
240W
240W
240W
Power supply
AC220V,50/60Hz(Standard);AC110V,60HZ(Optional)
AC220V,50/60Hz(Standard);AC110V,60HZ(Optional)
AC220V,50/60Hz(Standard);AC110V,60HZ(Optional)
AC220V,50/60Hz(Standard);AC110V,60HZ(Optional)
External Size (H× W× D)
640*540*1110mm
640*540*1110mm
640*540*1110mm
640*540*1110mm
Package size (H× W× D)
650*750*1280mm
650*750*1280mm
650*750*1280mm
650*750*1280mm
W e ight
90kg
90kg
90kg
90kg

Compare models in this series

Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.

This model belongs to the HWP-V series. The series overview lists every model side by side. Open series overview

ParameterHWP-IHWP-IIHWP-IIIHWP-IVThis modelHWP-V
W ater Output TypeRO water outlet*1 and DI water outlet*1 / RO water outlet*1 and DI water outlet*1RO Water / RO WaterRO and DI Water / RO and DI WaterR O water / RO water / RO water / RO waterRO and DI water / RO and DI water / RO and DI water / RO and DI water
W ater Output Speed10 L/H / 15 L/H15L/H / 30L/H15L/H / 30L/H45L/H / 63L/H / 94L/H / 125L/H45L/H / 63L/H / 94L/H / 125L/H
Flow procedure———PF+AC+AC+RO / PF+AC+AC+RO / PF+AC+AC+RO / PF+AC+AC+ROPF+AC+AC+RO+DI+TF / PF+AC+AC+RO+DI+TF / PF+AC+AC+RO+DI+TF / PF+AC+AC+RO+DI+TF
Water Supply RequirementWhen working, the inlet water pressure is 0.1 - 0.3Mpa, and the water quality meets the requirements of GB5749,15 - 35 ° C / When working, the inlet water pressure is 0.1 - 0.3Mpa, and the water quality meets the requirements of GB5749,15 - 35 ° CTap water:TDS<200 ppm,5~45° C,1.0 - 4.0kg/c / Tap water:TDS<200 ppm,5~45° C,1.0 - 4.0kg/cTap water:TDS<200 ppm,5~45° C,1.0 - 4.0kgf/cm2 (If inlet TDS > 200 ppm ,extra pretreatment filter is recommended) / Tap water:TDS<200 ppm,5~45° C,1.0 - 4.0kgf/cm2 (If inlet TDS > 200 ppm ,extra pretreatment filter is recommended)T ap water: TDS 200ppm, extra pretreatment filter is recommended) / T ap water: TDS 200ppm, extra pretreatment filter is recommended) / T ap water: TDS 200ppm, extra pretreatment filter is recommended) / T ap water: TDS 200ppm, extra pretreatment filter is recommended)Tap water: TDS 200ppm, extra pretreatment filter is recommended) / Tap water: TDS 200ppm, extra pretreatment filter is recommended) / Tap water: TDS 200ppm, extra pretreatment filter is recommended) / Tap water: TDS 200ppm, extra pretreatment filter is recommended)
Purificatio n system Pretreatment unit—PP filter× 1 + PP cotton filter× 1 / PP filter× 1 + PP cotton filter× 1—20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 120" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1 / 20" PP filter× 1+20" granular active carbon filter× 1+20" active carbon block filter× 1
RO unit—100GPD RO membrane× 1 / 200GPD RO membrane× 1—300 GPD RO membrane× 1 / 400 GPD RO membrane× 1 / 600 GPD RO membrane× 1 / 400 GPD RO membrane× 2300 GPD RO membrane× 1 / 400 GPD RO membrane× 1 / 600 GPD RO membrane× 1 / 400 GPD RO membrane× 2
Pure water quality Ion rejection rate—97%~99% (New RO membrane) / 97%~99% (New RO membrane)—97%~99% (New RO membrane) / 97%~99% (New RO membrane) / 97%~99% (New RO membrane) / 97%~99% (New RO membrane)—
Organic rejection rate—99%,when MW > 200 Dalton / 99%,when MW > 200 Dalton—> 99%,when MW > 200 Dalton / > 99%,when MW > 200 Dalton / > 99%,when MW > 200 Dalton / > 99%,when MW > 200 Dalton—
Bacteria—<0.1cfu (with optional 0.45+0.1 μ m PES terminal filter) / <0.1cfu (with optional 0.45+0.1 μ m PES terminal filter)—<0.01cfu/ml (with optional 0.2 μ m PES terminal filter) / <0.01cfu/ml (with optional 0.2 μ m PES terminal filter) / <0.01cfu/ml (with optional 0.2 μ m PES terminal filter) / <0.01cfu/ml (with optional 0.2 μ m PES terminal filter)—
Water Quality Monitor——TDS/conductivity test pen / TDS/conductivity test penTDS/conductivity test pen / TDS/conductivity test pen / TDS/conductivity test pen / TDS/conductivity test pen—
Consumption46W / 46W—72W / 72W120W / 240W / 240W / 240W120W / 240W / 240W / 240W
Power supplyAC220 V± 10%,50Hz ± 10% / AC220 V± 10%,50Hz ± 10%AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional)AC220V,50/60Hz(Standard) / AC220V,50/60Hz(Standard)AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional) / AC220V,50/60Hz(Standard);AC110V,60HZ(Optional)AC220V, 50/60Hz(Standard) / AC220V, 50/60Hz(Standard) / AC220V, 50/60Hz(Standard) / AC220V, 50/60Hz(Standard)
External Size (H× W× D)—410*220*420mm / 410*220*420mm410*220*420mm / 410*220*420mm640*540*1110mm / 640*540*1110mm / 640*540*1110mm / 640*540*1110mm640*540*1110mm / 640*540*1110mm / 640*540*1110mm / 640*540*1110mm
Package size (H× W× D)—600*490*580mm / 600*490*580mm600*490*580mm / 600*490*580mm650*750*1280mm / 650*750*1280mm / 650*750*1280mm / 650*750*1280mm650*750*1280mm / 650*750*1280mm / 650*750*1280mm / 650*750*1280mm
W e ight—35kg / 35kg—90kg / 90kg / 90kg / 90kg90kg / 90kg / 90kg / 90kg
Purifying P rocedurePF+AC+RO+DI / PF+AC+RO+DIPF+AC+RO+ AC / PF+AC+RO+ ACPF+AC+RO+DI / PF+AC+RO+DI——

Configuration

  • Main body (include 1 set of purification column)
  • 2 built-in 15L water tank
  • Accessory pack

Options & accessories

  • 0.2 μ m PES terminal filter
  • TDS meter, Online resistivity monitor
  • AC110V,60HZ Power supply

Warranty and after-sales service for HWP-IV

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →