H2O2 Low Temperature Plasma Sterilizer HO-DZ100,DZ130,DZ220 - H2O2 Low-Temp Plasma | HQS Medical
H2O2 Low-Temp Plasma

H2O2 Low Temperature Plasma Sterilizer HO-DZ100,DZ130,DZ220

Model: HO-DZ100,DZ130,DZ220

Introduction — H2O2 Low Temperature Plasma Sterilizer

The HO-DZ series H2O2 Low Temperature Plasma Sterilizer offers automatic door vertical sterilization with electric heating. Designed for efficient and reliable sterilization, it features a user-friendly LCD touch screen, advanced PLC control system, and integrated printer for data logging. Available in multiple volumes, these sterilizers ensure optimal performance and safety for veterinary medical equipment.

Key Features — HO-DZ100,DZ130,DZ220

  • 7-inch color touch screen
  • Stores and records sterilization data of 500 times
  • Microcomputer-controlled biological indicator dedicated constant temperature incubator
  • Two programs: strengthen circulation and rapid circulation
  • Vacuum pumps of well-known domestic manufacturers
  • High vacuum baffle solenoid valve to control evacuation pipeline
  • Cartridge filling method for hydrogen peroxide
  • Over-voltage and over-temperature protection functions
  • Door anti-pinch function with door barrier switch
  • Loading method: upper and lower two layers of aluminum alloy punching plates
  • Door opening method: jack-driven electric lifting door with light-sensing infrared sensor switch
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for HO-DZ100,DZ130,DZ220

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

HO-DZ100,DZ130,DZ220 H2O2 Low Temperature Plasma Sterilizer product datasheet

Public PDF

HQS datasheet for the HO-DZ100,DZ130,DZ220: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
HO-DZ100,DZ130,DZ220
Length
3 pages
File
PDF · 275 KB
Web copy prepared
Need a different language or configuration-specific document?

H2O2 Low Temperature Plasma Sterilizer Specifications

PARAMETER
SPECIFICATION
Product name
Low temperature plasma hydrogen peroxide sterilizer
Product form
Automatic door vertical
Heating method
Electric heating
Power / Volume / Chamber size
HO - DZ100: 3.5KVA / 100L (Liner size: 700 ×430 ×360mm) HO - DZ130: 4.2KVA / 135L (Liner size: 750 ×450 ×400mm) HO - DZ220: 4.8KVA / 190L (Liner size: 820 ×510×460mm)
Power
AC220V, 50Hz
Working temperature
40 - 60 ℃
Select sterilizer
58% - 60% hydrogen peroxide (H202)
Sterilization time
35 - 55 minutes
Installation environment
10 - 40 ℃
Temperature display
LCD touch screen
Maximum anti - stress value
10pa
Operation height
≤160cm
Material of Sterilization Room
Using high - quality 5052 aluminum material, the cavity structure is rectangular, to improve space utilization, cavity thickness ≥ 8mm, has excellent thermal conductivity.
Outer box material
ABS plastic disposable plastic.
Electrode mesh material
aluminum alloy material 5052, sheet metal forming, thickness ≥ 2mm.
Sealing door material
5052 aluminum alloy material, thickness ≥15mm.
Cavity temperature heating power
-
Preheating heating time
≤30min.
Main insulation
≥20mm rubber and plastic sponge.
Full automatic control system
LCD circuit touch screen display PLC circuit design, safe and reliable, the system can be maintained and upgraded.
Printer
A micro - printer is used to print out the data every minute during the entire sterilization process, which can be permanently saved.
PLC
Use Siemens smart series PLC control system.
Display screen
A 7 - inch color touch screen is used, and the communication rate is ≥ 19.2Kbps.
Display status
Temperature, pressure, time, cycle mode, process stage and alarm information, etc., and provide actual interface photos.
Storage function
It can store and record the sterilization data of 500 times.
Biological indicator incubator
A microcomputer - controlled biological indicator dedicated constant temperature incubator is used for the constant temperature cultivation process of the biological indicator for sterilization effect monitoring. The temperature control accuracy is ≤ ± 0.3 ℃ within the full range; the temperature can be set by itself .
Pressure Sensor
The built - in pressure sensor adopts imported sensors to automatically detect the pressure in the cavity to ensure that the accuracy of the pressure in the cavity is controlled within the effective range.
Temperature Sensor
The built - in temperature sensor automatically detects the temperature in the cavity to ensure that the temperature in the cavity is kept within the precise range of 50 ℃ ± 5 ℃ .
Program system
There are two programs to strengthen circulation and rapid circulation.
Network Connection
There is a network connection port.
Vacuum system
The vacuum pumps of well - known domestic manufacturers are used, which are simple and convenient, with a fast vacuum rate and a long service life.
Evacuation Control Valve
Adopt high vacuum baffle solenoid valve to control the evacuation pipeline.
Oil mist filter
The product has an exhaust oil mist filter system.
Air filter
The filtration accuracy is less than or equal to 0.22 μ m.
Plasma power supply
Adopt transistor control power supply, power ≤800W, with the advantages of stable power output and high frequency accuracy.
Hydrogen peroxide filling method
Cartridge filling method.
Sterilization effect
The silicone hose with an inner diameter of 1mm and a length of 4m can achieve the sterilization effect.
Heating System
Adopt explosion - proof flame retardant heating system.
Various protection functions
With over - voltage and over - temperature protection functions.

Compare models in this series

Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.

ParameterHO-D60HO-D100,D130,D220HO-DZ100,DZ130,DZ220This model
Product nameLow temperature plasma hydrogen peroxide sterilizerLow temperature hydrogen peroxide plasma sterilizerLow temperature plasma hydrogen peroxide sterilizer
Product formManual door verticalAutomatic door verticalAutomatic door vertical
Power2.6KWVolume / Chamber sizeAC220V, 50Hz
Sterilization time35 - 50min35 - 50 minutes35 - 55 minutes
Installation environment—10 - 50 ℃10 - 40 ℃
Operation height≤140cm≤160cm≤160cm
Outer box materialABS plasticABS plasticABS plastic disposable plastic.
Electrode mesh materialaluminum alloy material 5052, sheet metal forming, thickness ≥ 2mmaluminum alloy material 5052, sheet metal forming, thickness ≥ 2mm.aluminum alloy material 5052, sheet metal forming, thickness ≥ 2mm.
Sealing door material5052 aluminum alloy material, thickness ≥15mm—5052 aluminum alloy material, thickness ≥15mm.
Preheating heating time≤30min≤30min.≤30min.
Full automatic control systemLCD circuit touch scre en display PLC circuit design, safe and reliable.LCD circuit touch screen display PLC circuit design, safe and reliable.LCD circuit touch screen display PLC circuit design, safe and reliable, the system can be maintained and upgraded.
Display screenA 7 - i nch color touch screen is used, and the communication rate is ≥ 19.2Kbps.A 7 - inch color touch screen is used, and the communication rate is ≥ 9600bps.A 7 - inch color touch screen is used, and the communication rate is ≥ 19.2Kbps.
Display statusTemperature, pressure, time, cycle mode, process stage and alarm information, etc.Temperature, pressure, time, cycle mode, process stage and alarm information, etc.Temperature, pressure, time, cycle mode, process stage and alarm information, etc., and provide actual interface photos.
Storage function—Able to store and record 500 sterilization dataIt can store and record the sterilization data of 500 times.
Biological indicator incubator—A microcomputer-controlled biological indicator dedicated constant temperature incubator with a temperature control accuracy of ≤ ± 0.3 ° C within the full range.A microcomputer - controlled biological indicator dedicated constant temperature incubator is used for the constant temperature cultivation process of the biological indicator for sterilization effect monitoring. The temperature control accuracy is ≤ ± 0.3 ℃ within the full range; the temperature can be set by itself .
Pressure SensorThe built - in pressure sensor uses imported sensors.The built - in pressure sensor uses imported sensors.The built - in pressure sensor adopts imported sensors to automatically detect the pressure in the cavity to ensure that the accuracy of the pressure in the cavity is controlled within the effective range.

Buyer decision support

HO-DZ series procurement decision notes

The HO-DZ series uses one hydrogen peroxide plasma design in three chamber sizes: HO-DZ100 (100 L), HO-DZ130 (135 L) and HO-DZ220 (190 L). Cycle, controls and door design are shared, so choose on load volume, electrical capacity and room space.

Decision factorPublished for this modelConfirm before order
Chamber sizeHO-DZ100: 100 L (700 × 430 × 360 mm); HO-DZ130: 135 L (750 × 450 × 400 mm); HO-DZ220: 190 L (820 × 510 × 460 mm)Measure your largest instrument trays and daily load count, then pick the smallest chamber that fits two loading layers.
Electrical loadAC 220 V 50 Hz; 3.5 kVA (DZ100), 4.2 kVA (DZ130), 4.8 kVA (DZ220)Check that the installation circuit can carry the rated kVA of the chosen model.
Cycle40–60 °C working temperature; 35–55 min sterilization; strengthened and rapid programs; preheating ≤ 30 minConfirm which of your heat- and moisture-sensitive instruments and packaging materials are compatible with hydrogen peroxide plasma.
Sterilant58–60 % hydrogen peroxide, cartridge fillingAsk for the cartridge part number, cycles per cartridge and local supply before ordering.
Records and monitoring7-inch colour touch screen, Siemens PLC, micro-printer printing every minute, 500-cycle storage, network port, built-in biological-indicator incubator (± 0.3 °C)Confirm how cycle records are exported if your audits need digital copies.
Site conditionsInstallation environment 10–40 °C; operation height ≤ 160 cm; electric lifting door with infrared switch and anti-pinch barrier; air filter ≤ 0.22 µmPlan floor space, door clearance and room temperature for the chosen cabinet.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: specifications currently published for this model. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for HO-DZ100,DZ130,DZ220

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →