Ethylene Oxide Gas Sterilizer EO-H40 - Ethylene Oxide Gas | HQS Medical
Ethylene Oxide Gas

Ethylene Oxide Gas Sterilizer EO-H40

Model: EO-H40

Introduction — Ethylene Oxide Gas Sterilizer

The EO-H40 Ethylene Oxide Gas Sterilizer is a desktop unit designed for efficient and safe sterilization. It features electric heating, a 3.5-inch LCD display for real-time status monitoring, and a fully automatic one-click start to finish process. The sterilizer includes advanced features like automatic ventilation, a built-in humidity sensor, pressure sensor, and temperature sensor, along with a residual gas treatment device and multiple protection functions for enhanced safety and reliability.

Key Features — EO-H40

  • One-click start to finish, the whole process is completed automatically
  • 304 stainless steel aluminum material door, thickness ≥ 2mm, pressure resistance 200Kpa
  • Filtration rate of the filter to particle diameter ≥0.3 μm is not less than 99.5%
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for EO-H40

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

EO-H40 Ethylene Oxide Gas Sterilizer product datasheet

Public PDF

HQS datasheet for the EO-H40: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
EO-H40
Length
2 pages
File
PDF · 235 KB
Web copy prepared
Need a different language or configuration-specific document?

Ethylene Oxide Gas Sterilizer Specifications

PARAMETER
SPECIFICATION
Product name
Ethylene Oxide Sterilizer
Product model
EO - H40
Product form
Desktop
Heating method
Electric heating
Power
1.3KVA
Power
AC220V, 50Hz
Dimensions (Length ×Width ×Height)
670 × 450 ×400mm
Liner size (Length ×Width ×Height)
240 x 470 mm
Effective Volume
23L
Weight
56kg
Temperature display
3.5 inch LCD display
Material of Sterilization Room
304 anti-corrosion stainless steel
Outer box material
ABS plastic
Temperature during sterilization
50 ℃ ± 3 ℃
Working pressure
- 60kpa
Highest anti-stress value
- 140kpa
Humidity during sterilization
45% - 80%
Selected gas
Pure ethylene oxide gas
Sterilization time
0 - 99 hours adjustable
Air Replacement
Automatic ventilation, 5 cycles of ventilation, every 15 minutes
Full-automatic control
One-click start to finish, the whole process is completed system automatically
Sterilization record
The system can store 500 pots of sterilization records
Display status
Display operating status, temperature, humidity, pressure, sterilization time, residual gas treatment time, times, steam generator temperature.
Humidity Sensor
The built-in humidity sensor automatically detects the humidity in the cavity.
Pressure Sensor
The built-in pressure sensor automatically detects the pressure in the cavity
Temperature Sensor
The built-in temperature sensor automatically detects the temperature in the cavity, the accurate range is 50 ℃ ± 3 ℃ .
Vacuum system
Use oil-free vacuum pump.
Seal door
304 stainless steel aluminum material, thickness ≥ 2mm, pressure resistance 200Kpa.
Humidification System
Using pulse steam humidification
Residual gas treatment device
The filtration rate of the filter to the particle diameter ≥0.3 μ m i s not less than 99.5%
Vacuum rate
Under no-load conditions, the time for the sterilizer to be vacuumed from normal pressure to - 60 kPa ≤ 30 min
Automatic dosing
Puncture technology built into the sterilization chamber.
Heating system
The explosion-proof electric heating device is used in the sterilization chamber
Multiple protection functions
With over-voltage and over-temperature protection functions, it is more safe and reliable
Alarm system
Have high temperature alarm system, ultra low pressure alarm system

Compare models in this series

Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.

ParameterEO-H40This modelEO-HSeries
Product formDesktopVertical
Power1.3KVAAC220V, 50Hz
Outer box materialABS plasticCarbon steel spray plastic

Buyer decision support

EO-H40 procurement decision notes

The EO-H40 is the desktop 23 L model; the vertical EO-H series covers larger chambers from 70 L. Both run the same 50 °C ethylene oxide cycle, so the choice is mainly chamber volume, site and ventilation.

Decision factorPublished for this modelConfirm before order
Chamber volumeEO-H40: 23 L desktop; vertical EO-H series from 70 L (EO-H80)Size the chamber to your largest instrument set and daily load count.
Cycle conditions50 ± 3 °C, −60 kPa working pressure, 45–80 % humidity, 0–99 h sterilization timeConfirm that your instruments and packaging are compatible with ethylene oxide at 50 °C.
AerationAutomatic ventilation, 5 cycles, every 15 minutes; residual-gas filter ≥ 99.5 % at ≥ 0.3 µmPlan the exhaust route and ask for the recommended aeration time before items are reused.
Gas supplyPure ethylene oxide gas; built-in puncture dosingConfirm the gas cartridge type, local availability and storage rules for ethylene oxide.
RecordsStores 500 sterilization recordsConfirm how records are exported if you need them for audits.
Power and sizeAC 220 V 50 Hz, 1.3 kVA; 670 × 450 × 400 mm, 56 kgCheck the bench space and the electrical circuit at the installation site.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: specifications currently published for this model. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for EO-H40

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →