Horizontal Cylindrical Pressure Steam Sterilizer WS-YDB - Horizontal Cylindrical Type | HQS Medical
Horizontal Cylindrical Type

Horizontal Cylindrical Pressure Steam Sterilizer WS-YDB

Model: WS-YDB

Introduction — Horizontal Cylindrical Pressure Steam Sterilizer

The WS-YDB Horizontal Cylindrical Pressure Steam Sterilizer offers automated computer control for sterilization cycles, simplifying operation. It includes a drying function suitable for dressings and features comprehensive safety mechanisms such as over-temperature and over-pressure auto-protection, interlocks to prevent door operation under pressure, and automatic power cut-off with water supply interruption and alarm in case of low water levels. The exterior is steel-coated, while the chamber is constructed from stainless steel, and a printer is included for record-keeping.

Key Features — WS-YDB

  • Sterilizing course automatic sterilization controlled by computer, easy to operate.
  • With drying function, suitable dressing drying.
  • With over - temperature, over - pressure auto - protect device.
  • The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.
  • It can ’ t be start on if the doesn ’ t closed well.
  • The safety value will be open automatically when the inner pressure over 0.24MPa, and the steam be exhausting to the water tank.
  • The surface of the sterilizer is steel coated , the chamber of the sterilizer is made of stainless steel.
  • With printer.
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for WS-YDB

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

WS-YDB Horizontal Cylindrical Pressure Steam Sterilizer product datasheet

Public PDF

HQS datasheet for the WS-YDB: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
WS-YDB
Length
2 pages
File
PDF · 239 KB
Web copy prepared
Need a different language or configuration-specific document?

Horizontal Cylindrical Pressure Steam Sterilizer Specifications

technical data
WS - 280YDB
WS - 200YDB
WS - 150YDB
Sterilizing chamber volume
280L( φ 600 × 1000mm)
200L( φ 515 × 1000mm)
150L( φ 440 × 1000mm)
working pressure
0.22 MPa
0.22 MPa
0.22 MPa
working temperature
134 ℃
134 ℃
134 ℃
Adjustment of temperature
40 ℃ - 134 ℃
40 ℃ - 134 ℃
40 ℃ - 134 ℃
Time of sterilization
0 - 99 min
0 - 99 min
0 - 99 min
Time of drying
0 - 99 min
0 - 99 min
0 - 99 min
Heat average
≤± 2 ℃
≤± 2 ℃
≤± 2 ℃
Power
12KW/380V 50Hz
9KW/380V 50Hz
9KW/380V 50Hz
Dimension
1520× 910× 1900
1400× 750× 1700
1400× 650× 1600
Package
1680× 1080× 2100
1560× 910× 1880
1560× 820× 1820
GW/NW
570/462 KG
436/350 KG
430/340 KG

Compare models in this series

Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.

ParameterWS-YDAWS-YDBThis modelWS-YDC
Sterilizing chamber volume—280L( φ 600 × 1000mm) / 200L( φ 515 × 1000mm) / 150L( φ 440 × 1000mm)280L( φ 600 × 1000mm) / 200L( φ 515 × 1000mm) / 150L( φ 480 × 850mm)
working pressure0.22MPa / 0.22MPa0.22 MPa / 0.22 MPa / 0.22 MPa0.22 MPa / 0.22 MPa / 0.22 MPa
working temperature134 ℃ / 134 ℃134 ℃ / 134 ℃ / 134 ℃134 ℃ / 134 ℃ / 134 ℃
Adjustment of temperature115 ℃ - 134 ℃ / 115 ℃ - 134 ℃40 ℃ - 134 ℃ / 40 ℃ - 134 ℃ / 40 ℃ - 134 ℃115 ℃ - 134 ℃ / 115 ℃ - 134 ℃ / 115 ℃ - 134 ℃
Time of sterilization0 - 60 min / 0 - 60 min0 - 99 min / 0 - 99 min / 0 - 99 min0 - 60 min / 0 - 60 min / 0 - 60 min
Time of drying0 - 60 min / 0 - 60 min0 - 99 min / 0 - 99 min / 0 - 99 min0 - 60 min / 0 - 60 min / 0 - 60 min
Heat average≤± 2 ℃ / ≤± 2 ℃≤± 2 ℃ / ≤± 2 ℃ / ≤± 2 ℃≤± 2 ℃ / ≤± 2 ℃ / ≤± 2 ℃
Dimension1700 × 950 × 1900 / 1800 × 1050 × 20001520× 910× 1900 / 1400× 750× 1700 / 1400× 650× 16001500× 850× 1850 / 1450× 700× 1700 / 1420× 600× 1600
Package—1680× 1080× 2100 / 1560× 910× 1880 / 1560× 820× 18201680× 920× 2100 / 1560× 820× 1850 / 1550× 750× 1850
GW/NW—570/462 KG / 436/350 KG / 430/340 KG700/460 KG / 500/350 KG / 350/280 KG

Buyer decision support

WS-YDB / WS-YDA / WS-YDC horizontal cylindrical pressure steam sterilizer procurement decision notes

HQS lists three series of horizontal cylindrical pressure steam sterilizers. All list a working pressure of 0.22 MPa, a working temperature of 134 °C, heat average within ±2 °C, a drying function, a door that cannot be opened until chamber pressure falls to 0.027 MPa, a safety valve and 380 V 50 Hz power. The WS-YDB comes in three sizes: WS-280YDB (280 L, φ600 × 1000 mm chamber, 12 kW), WS-200YDB (200 L, φ515 × 1000 mm, 9 kW) and WS-150YDB (150 L, φ440 × 1000 mm, 9 kW). It is computer controlled, with temperature adjustment from 40 to 134 °C, sterilizing and drying timers of 0–99 min, a built-in printer, a steel-coated exterior and a stainless steel chamber. The WS-YDC has the same 280, 200 and 150 L sizes and power ratings, but it is fully stainless steel, lists 0–60 min timers, buzzer and pilot-light alarms, and overload and leakage protection; no printer is listed. The WS-YDA is the larger series, with 400 L and 500 L chambers and 0–60 min timers. Choose the series by chamber volume and load size, then check whether you need a printed cycle record, a fully stainless body and a 380 V three-phase supply.

Decision factorPublished for this modelConfirm before order
Chamber volume and sizeWS-280YDB: 280 L, φ600 × 1000 mm. WS-200YDB: 200 L, φ515 × 1000 mm. WS-150YDB: 150 L, φ440 × 1000 mm. WS-YDC: the same three volumes. WS-YDA: 400 L and 500 LTell us your largest packs, trays or drapes and the loads you run each day so we can confirm the chamber size and the baskets or racks supplied.
Pressure, temperature and cycle settingsAll WS-YDB sizes: working pressure 0.22 MPa; working temperature 134 °C; temperature adjustment 40–134 °C; sterilizing time 0–99 min; drying time 0–99 min; heat average ≤ ±2 °C. WS-YDA and WS-YDC: sterilizing and drying time 0–60 minAsk which preset programs are stored and how the cycle parameters are set and locked for your loads.
Control, safety and recordComputer-controlled automatic cycle; drying function for dressings; over-temperature and over-pressure protection; door cannot be opened until chamber pressure falls to 0.027 MPa and the cycle cannot start if the door is not closed properly; safety valve opens above 0.24 MPa and vents steam to the water tank; on low water the power and water are cut off and an alarm sounds; built-in printerAsk for the printer paper type and what each printout records, and for the safety-valve and door-seal service intervals.
Heating, power and waterWS-280YDB: 12 kW, 380 V 50 Hz. WS-200YDB and WS-150YDB: 9 kW, 380 V 50 Hz. Steel-coated exterior, stainless steel chamberConfirm that you have a 380 V three-phase 50 Hz supply rated for the load; for other mains, ask before ordering. Also ask about water quality, the water supply and drain connections, and installation.
Dimensions and weightWS-280YDB: 1520 × 910 × 1900 mm; packed 1680 × 1080 × 2100 mm; 570 / 462 kg (gross / net). WS-200YDB: 1400 × 750 × 1700 mm; packed 1560 × 910 × 1880 mm; 436 / 350 kg. WS-150YDB: 1400 × 650 × 1600 mm; packed 1560 × 820 × 1820 mm; 430 / 340 kgCheck doorways, the delivery route, floor loading and service clearance around the unit before ordering.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: specifications currently published for this model. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for WS-YDB

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →