| Speed, force and timer | LC-06F(Table): 5000 rpm, speed accuracy ± 20 rpm; 4730 ×g; timer up to 99 h 59 min. LC-06F: 6000 rpm, stepless speed adjustment; 5120 ×g (rotor 1); timer 0–99 min. LC-05F: 5000 rpm, 4390 ×g. LC-04F: 4000 rpm, 2755 ×g. LC-05F, LC-04F: stepless speed adjustment; timer 0–99 min | Check the RCF and run time in your protocols, and ask for the maximum speed and RCF of each LC-06F(Table) rotor you plan to order. |
|---|
| Rotors and capacity | LC-06F(Table): maximum volume 4 × 800 ml; optional rotors 10/15 ml × 12 angle rotor, 750 ml × 4, 500 ml × 4, 250 ml × 4, 500 ml blood bag × 4, 500 ml × 6, 5 ml × 72, 7 ml × 148/108, 96 holes × 2 × 2, 50 ml × 8, 10/15 ml × 32, 15 ml × 16, 100 ml × 4, 100 ml × 8. LC-06F: standard rotor 10/15 ml × 12 (6000 r/min, 5120 ×g); optional 750 ml × 4 or 500 ml × 4 (4000 r/min, 3780 or 3500 ×g), 250 ml × 4 (4000 r/min, 3500 ×g), 500 ml blood bag × 4 (4000 r/min, 3780 ×g); swing rotor up to 500 ml × 6. LC-05F: swing rotor 250 ml × 4, 50 ml × 8, 15 ml × 24, 10 ml × 36. LC-04F: swing rotor 100 ml × 4, 50 ml × 8, 15 ml × 16, 10 ml × 24 | List your tube, bottle, blood bag and microplate formats so we can confirm which rotors, buckets and adapters are included in the quotation and which are extras. |
|---|
| Temperature | LC-06F(Table) and LC-06F: −20 °C to +40 °C; LC-06F temperature precision ± 2 °C. LC-05F, LC-04F: −5 °C to +30 °C, ± 2 °C. LC-06F, LC-05F, LC-04F: French refrigeration compressor | State your working temperature and ask for the pre-cooling time to reach it with your rotor fitted. |
|---|
| Drive, control and display | LC-06F(Table): microprocessor control; brushless frequency motor; flexible axle driving the rotor directly; digital display of speed, time and RCF. LC-06F: vertical type; DC brushless frequency motor; touch panel; LCD showing speed, RCF and time; error code display. LC-05F, LC-04F: vertical type; DC brushless frequency motor; touch panel; LED display of speed, RCF and time; error code display | Ask how many programs can be stored and whether speed can be set in rpm or RCF on the model you choose. |
|---|
| Safety | LC-06F(Table): auto-electric lid lock; over-speed protection. LC-06F: safety switch and electromagnetic door locks; automatic malfunction alarm; over-speed, over-temperature and unbalance protection; fault self-diagnosis. LC-05F, LC-04F: safety switch and electromagnetic door locks; automatic malfunction alarm | Ask for the imbalance tolerance, the error-code list and the recommended rotor inspection interval. |
|---|
| Power, size and weight | All: 220 V 50 Hz. LC-06F(Table): 700 × 715 × 420 mm, 130 kg. LC-06F: 790 × 620 × 820 mm, 150 kg. LC-05F, LC-04F: 500 × 560 × 700 mm, 85 kg | Confirm voltage, frequency and plug type; for the LC-06F(Table), check that your bench can carry 130 kg with clearance to open the lid and ventilate. |
|---|