Refrigerated Centrifuge LC-06F(Table) - Centrifuge | HQS Medical
Centrifuge

Refrigerated Centrifuge LC-06F(Table)

Model: LC-06F(Table)

Introduction — Refrigerated Centrifuge

The LC - 06F (Table) Refrigerated Centrifuge features a melt housing for a safe and compact design. It offers microprocessor control for quiet operation and rapid cooling, utilizing a brushless frequency motor for maintenance-free performance and reduced powder pollution. Its flexible axle-driven system ensures smooth operation with minimal vibration, and a variety of rotors are available to meet diverse separation needs. The digital display shows speed, time, and RCF, with an auto-electric lid lock and over-speed protection for enhanced safety.

Key Features — LC-06F(Table)

  • Melt housing, safe & compact
  • Microprocessor control, less noise and fast cooling
  • Brush-less frequency motor, free maintenance, no powder pollution, quick in speed up and down
  • Flexible axle driven system which drive the rotor directly, smooth in operation and small vibration
  • Many rotors for choice, suitable for different specifications meets customers ’ different requirements of separation
  • Digital display the speed, time and RCF
  • Auto - electric lid lock, over - speed protection
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for LC-06F(Table)

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

LC-06F(Table) Refrigerated Centrifuge product datasheet

Public PDF

HQS datasheet for the LC-06F(Table): product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
LC-06F(Table)
Length
2 pages
File
PDF · 224 KB
Web copy prepared
Need a different language or configuration-specific document?

Refrigerated Centrifuge Specifications

Specification
Value
Max speed
5000rpm
Speed accuracy
± 20rpm
Max RCF
4730× g
Timer
99h59min
Max volume
4× 800ml
Temperature range
- 20 ℃ ~40 ℃
Power supply
220V 50HZ
Dimension(mm)
700× 715× 420
Weight
130kg

Compare models in this series

Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.

ParameterLC-06FLC-06F(Table)This model
Max RCF5120xg4730× g
Temperature range- 20 ℃ ~ +40 ℃- 20 ℃ ~40 ℃
Weight150kg130kg

Options & accessories

  • Optional Rotors

Buyer decision support

LC-06F(Table) / LC-06F / LC-05F / LC-04F refrigerated centrifuge procurement decision notes

The LC-06F(Table) is the refrigerated centrifuge in the HQS LC series with the widest rotor choice. It reaches 5000 rpm (speed accuracy ± 20 rpm) and 4730 ×g, cools across −20 °C to +40 °C, has a 99 h 59 min timer and a maximum volume of 4 × 800 ml, with 14 optional rotors: a 10/15 ml × 12 angle rotor, rotors from 15 ml × 16 to 750 ml × 4, 500 ml × 6, a 500 ml blood bag × 4 rotor, 5 ml × 72 and 7 ml × 148/108 tube rotors, and a 96-hole × 2 × 2 microplate rotor. It uses a brushless frequency motor with direct flexible-axle drive, a digital display of speed, time and RCF, an electric lid lock and over-speed protection; 700 × 715 × 420 mm, 130 kg. The LC-06F is the vertical model with the same −20 °C to +40 °C range: 6000 rpm and 5120 ×g on its standard 10/15 ml × 12 rotor, up to 500 ml × 6 on a swing rotor, four rotor options, a 0–99 min timer, touch panel, LCD, unbalance and over-temperature protection, 740 × 620 × 780 mm and 100 kg. The LC-05F (5000 rpm, 4390 ×g, swing rotor up to 250 ml × 4) and LC-04F (4000 rpm, 2755 ×g, up to 100 ml × 4) are smaller vertical low-speed units with a −5 °C to +30 °C range, 500 × 560 × 700 mm and 85 kg. Choose the LC-06F(Table) for microplates, many small tubes, blood bags or long runs; the LC-06F for the highest RCF on 10/15 ml tubes; the LC-05F or LC-04F for routine tube work above −5 °C.

Decision factorPublished for this modelConfirm before order
Speed, force and timerLC-06F(Table): 5000 rpm, speed accuracy ± 20 rpm; 4730 ×g; timer up to 99 h 59 min. LC-06F: 6000 rpm, stepless speed adjustment; 5120 ×g (rotor 1); timer 0–99 min. LC-05F: 5000 rpm, 4390 ×g. LC-04F: 4000 rpm, 2755 ×g. LC-05F, LC-04F: stepless speed adjustment; timer 0–99 minCheck the RCF and run time in your protocols, and ask for the maximum speed and RCF of each LC-06F(Table) rotor you plan to order.
Rotors and capacityLC-06F(Table): maximum volume 4 × 800 ml; optional rotors 10/15 ml × 12 angle rotor, 750 ml × 4, 500 ml × 4, 250 ml × 4, 500 ml blood bag × 4, 500 ml × 6, 5 ml × 72, 7 ml × 148/108, 96 holes × 2 × 2, 50 ml × 8, 10/15 ml × 32, 15 ml × 16, 100 ml × 4, 100 ml × 8. LC-06F: standard rotor 10/15 ml × 12 (6000 r/min, 5120 ×g); optional 750 ml × 4 or 500 ml × 4 (4000 r/min, 3780 or 3500 ×g), 250 ml × 4 (4000 r/min, 3500 ×g), 500 ml blood bag × 4 (4000 r/min, 3780 ×g); swing rotor up to 500 ml × 6. LC-05F: swing rotor 250 ml × 4, 50 ml × 8, 15 ml × 24, 10 ml × 36. LC-04F: swing rotor 100 ml × 4, 50 ml × 8, 15 ml × 16, 10 ml × 24List your tube, bottle, blood bag and microplate formats so we can confirm which rotors, buckets and adapters are included in the quotation and which are extras.
TemperatureLC-06F(Table) and LC-06F: −20 °C to +40 °C; LC-06F temperature precision ± 2 °C. LC-05F, LC-04F: −5 °C to +30 °C, ± 2 °C. LC-06F, LC-05F, LC-04F: French refrigeration compressorState your working temperature and ask for the pre-cooling time to reach it with your rotor fitted.
Drive, control and displayLC-06F(Table): microprocessor control; brushless frequency motor; flexible axle driving the rotor directly; digital display of speed, time and RCF. LC-06F: vertical type; DC brushless frequency motor; touch panel; LCD showing speed, RCF and time; error code display. LC-05F, LC-04F: vertical type; DC brushless frequency motor; touch panel; LED display of speed, RCF and time; error code displayAsk how many programs can be stored and whether speed can be set in rpm or RCF on the model you choose.
SafetyLC-06F(Table): auto-electric lid lock; over-speed protection. LC-06F: safety switch and electromagnetic door locks; automatic malfunction alarm; over-speed, over-temperature and unbalance protection; fault self-diagnosis. LC-05F, LC-04F: safety switch and electromagnetic door locks; automatic malfunction alarmAsk for the imbalance tolerance, the error-code list and the recommended rotor inspection interval.
Power, size and weightAll: 220 V 50 Hz. LC-06F(Table): 700 × 715 × 420 mm, 130 kg. LC-06F: 790 × 620 × 820 mm, 150 kg. LC-05F, LC-04F: 500 × 560 × 700 mm, 85 kgConfirm voltage, frequency and plug type; for the LC-06F(Table), check that your bench can carry 130 kg with clearance to open the lid and ventilate.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: specifications currently published for this model. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for LC-06F(Table)

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →