Video Gastroscope/Colonoscope FEC-8800 - Flexible Endoscopy System | HQS Medical
Flexible Endoscopy System

Video Gastroscope/Colonoscope FEC-8800

Model: FEC-8800

Introduction — Video Gastroscope/Colonoscope

The FEC-8800 is a high-resolution video gastroscope and colonoscope designed specifically for small pets. It features a flexible insertion tube, a wide field of view, and advanced image processing capabilities, including adjustable brightness, contrast, saturation, and electronic amplification. The system integrates with a powerful LED light source and a suction device, offering comprehensive diagnostic and therapeutic potential for veterinary endoscopy.

Key Features — FEC-8800

  • Used for Small Pets
  • Image frozen, video and picture record
  • Supports automatic and manual modes for sharpness adjustment
  • Supports automatic and manual modes for gain adjustment
  • Vascular enhancement can increase vascular clarity
  • Support 0 - 6 level image bad point correction
  • Support full screen image freezing and half screen mode to freeze large images and dynamically display small images
  • With USB interface support picture and video record function and pictures playback function
  • Support connect same series Video Gastroscope, Colonoscope, bronchoscope, laryngoscope, Cystoscope, Ureteroscope share this tower use
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for FEC-8800

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

FEC-8800 Video Gastroscope/Colonoscope product datasheet

Public PDF

HQS datasheet for the FEC-8800: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
FEC-8800
Length
4 pages
File
PDF · 425 KB
Web copy prepared
Need a different language or configuration-specific document?

Video Gastroscope/Colonoscope Specifications

PARAMETER
SPECIFICATION
Top diameter
≤ Φ 8.0mm
Input tube
≤ Φ 8.0mm
Biopsy channel
≥ Φ 2.0mm
Working length
≥1500mm
Total length
≥1800mm
Field of view
≥140º
Depth of field
≥3 - 100mm
Image solution
≥1,000,000 pixels CMOS
Bending angles
≥up 210º down ≥90º left&right ≥100º
Lamp
LED light (80W white)
Power
220 - 240V; 50 - 60HZ
Color temperature
≥5300K,140000lx illumination
Brightness
0 - 10 level adjustable
Video signal output
HDMI x2, DVI
Air pump pressure
30 - 60 kPa
Air pump power
Strong/ medium/ weak 3 level adjustable
Air flow
4 - 10 L/min
Withe balance
It supports 4 kinds of fixed white balance parameter selection, real - time dynamic white balance mode and manual white balance parameter setting mode, or one click white balance
Gain function
It supports automatic and manual modes, and the manual mode supports 0 - 16 level gain adjustment and 0 - 30 level exposure time adjustment
Electronic amplification
Support 1.2/1.5/1.7/2.0 times 4 - gear electronic amplification function
Package size
60*30*50cm (G.W.:13kgs)
Vessel capacity
1 L
Maximum suction volume
20 L / Min
Monitor
Samsung / Phillips 24” HD LCD monitor 1920X 1080

Compare models in this series

Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.

ParameterFEC-400AFEC-400DFEC-8800This model
Top diameter≤ Φ 14.0mm≤ Φ 12.8mm≤ Φ 8.0mm
Input tube≤ Φ 14.0mm≤ Φ 12.8mm≤ Φ 8.0mm
Biopsy channel≥ Φ 6.0mm≥ Φ 3.2 mm≥ Φ 2.0mm
Working length≥5000mm≥ 3000mm≥1500mm
Total length≥5300mm≥ 3300mm≥1800mm
Image solution≥480 , 000 pixels (CCD)≥480000 pixels (CCD )≥1,000,000 pixels CMOS
Bending anglesUp ≥180º , down ≥90º , L/R ≥100º , maximum 230up ≥ 210º , down ≥ 90º , left&right ≥ 100º , maximum 230≥up 210º down ≥90º left&right ≥100º
Vessel capacityNot less than 1 L—1 L
Illuminance≥200 , 000Lx , LED light source 30 , 000hours life≥200,000Lx—

Configuration

  • Video Flexible endoscopee Video gastroscope FEC-8800
  • Biopsy forceps
  • Cleaning brush
  • Mouth pad
  • Leak detector
  • Leak cover
  • Clean lid
  • Attract the valve body baffle cap
  • Water bottle interface seal ring
  • Wash ear ball
  • Water injection bottle assembly
  • Endoscopic box
  • Instructions
  • REC - 3000 Endoscope processor &light source ( With air pump , USB disk )
  • Suction device
  • Trolley

Buyer decision support

FEC-8800 / FEC-8600 / FEC-400D / FEC-400A video gastroscope and colonoscope procurement decision notes

The FEC-8800 is a video gastroscope/colonoscope supplied as a complete tower: the endoscope, a REC-3000 processor and 80 W white LED light source with air pump and USB recording, a suction device, a trolley and a 24-inch 1920 × 1080 HD LCD monitor. Its insertion tube and distal tip are ≤8.0 mm in diameter, with a ≥2.0 mm biopsy channel, ≥1500 mm working length (≥1800 mm total), a ≥140° field of view, 3–100 mm depth of field, a ≥1,000,000-pixel CMOS sensor and angulation of up ≥210°, down ≥90° and left/right ≥100°. The FEC-8600 uses the same processor, light source, image functions, suction device and monitor, but has a thinner ≤6.5 mm tube, a shorter ≥1200 mm working length (≥1500 mm total) and up angulation of ≥180°. The FEC-400D (listed for cattle and horses) and FEC-400A (listed for dolphins and similar aquarium animals) are long large-animal scopes with a ≥480,000-pixel CCD sensor, ≥200,000 lx LED illumination, 16-image freeze and 16 GB SD card recording: the FEC-400D has a ≤12.8 mm tube, ≥3.2 mm channel, ≥3000 mm working length and up angulation of ≥210°; the FEC-400A has a ≤14.0 mm tube, ≥6.0 mm channel, ≥5000 mm working length and up angulation of ≥180°. Choose by the tube diameter and working length your patients need, then by channel size for your instruments; choose the FEC-8800 over the FEC-8600 when you need the extra 300 mm of working length and 210° up angulation and can accept the 8.0 mm tube.

Decision factorPublished for this modelConfirm before order
Insertion tube, length and channelFEC-8800: distal tip and insertion tube ≤8.0 mm diameter; biopsy channel ≥2.0 mm; working length ≥1500 mm; total length ≥1800 mm. FEC-8600: ≤6.5 mm; ≥2.0 mm channel; ≥1200 mm working, ≥1500 mm total. FEC-400D: ≤12.8 mm; ≥3.2 mm channel; ≥3000 mm working, ≥3300 mm total. FEC-400A: ≤14.0 mm; ≥6.0 mm channel; ≥5000 mm working, ≥5300 mm totalTell us the species and body-weight range you scope and whether you need gastroscopy, colonoscopy or both, so we can confirm the tube diameter and working length; check that your biopsy forceps and other instruments fit a 2.0 mm channel.
Angulation and opticsFEC-8800: bending up ≥210°, down ≥90°, left/right ≥100°; field of view ≥140°; depth of field 3–100 mm; image sensor ≥1,000,000-pixel CMOS. FEC-8600: up ≥180°, down ≥90°, left/right ≥100°; same field of view, depth of field and CMOS sensor. FEC-400D: up ≥210°, down ≥90°, left/right ≥100°; FEC-400A: up ≥180°, down ≥90°, left/right ≥100°; both ≥140° field of view, 3–100 mm depth of field, ≥480,000-pixel CCDIf retroflexion in the stomach matters to you, compare the 210° up angulation of the FEC-8800 with the 180° of the FEC-8600 before ordering.
Image processor and recordingFEC-8800 and FEC-8600: REC-3000 processor with USB picture and video recording and picture playback; full-screen freeze and half-screen mode (frozen large image with live small image); sharpness auto/manual (manual 0–10 levels); gain auto/manual (0–16 gain levels, 0–30 exposure-time levels); brightness, contrast and saturation 0–100 levels; 4 fixed white balance settings, real-time dynamic, manual or one-click white balance; vascular enhancement; 1.2×/1.5×/1.7×/2.0× electronic magnification; 0–6 level bad-point correction; video output HDMI × 2 and DVI. FEC-400D and FEC-400A: 16-image freeze, store and playback; contrast 0–128; colour 0–128; image enhancement 0–30; AVE/PEAK metering; auto/manual white balance; 16 GB SD card recordingAsk which file formats are recorded to USB, and check that your monitor, recorder or capture system accepts HDMI or DVI input.
Light source, air supply and suctionFEC-8800 and FEC-8600: 80 W white LED; colour temperature ≥5300 K; 140,000 lx illumination; lamp brightness 0–10 levels; air pump strong/medium/weak 3-level adjustable; air flow 4–10 L/min; suction device with 1 L vessel and 20 L/min maximum suction. FEC-400D and FEC-400A: LED ≥200,000 lx, 30,000 h life; air supply 4–10 L/min; suction 20 L/min, vessel not less than 1 LAsk for the suction vessel, valve and seal spares to keep in stock, and the replacement interval for wearing parts.
Tower, power and supplyFEC-8800 standard configuration: endoscope; biopsy forceps × 6; cleaning brush; mouth pad × 3; leak detector; leak cover; clean lid; suction valve caps × 2; water bottle seal rings × 6; ear-wash bulb; water injection bottle assembly; endoscope case; REC-3000 processor and light source with air pump and USB disk; suction device; trolley; 24-inch HD LCD monitor, 1920 × 1080. Power 220–240 V, 50–60 Hz. Package size 60 × 30 × 50 cm, gross weight 13 kg. The processor can be shared with same-series video gastroscopes, colonoscopes, bronchoscopes, laryngoscopes, cystoscopes and ureteroscopesConfirm your mains voltage and plug type (220–240 V is listed), the number of shipping cartons for the full tower, and which other same-series scopes you may add to the REC-3000 later.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: specifications currently published for this model. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for FEC-8800

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →