Pet ICU Monitor HICU-05 - Vet ICU Incubator | HQS Medical
Vet ICU Incubator

Pet ICU Monitor HICU-05

Model: HICU-05

Introduction — Pet ICU Monitor

The universal pet ICU - HICU - 05 is an upgraded version of the HICU - 03, retaining core ICU functions like constant temperature, constant oxygen, atomization, blue light therapy, and UV sterilization. It features a biological status light for treatment progress, a dedicated oxygen generator position with integrated storage, and is designed to meet the diverse needs of veterinary medical institutions.

Key Features — HICU-05

  • Fully functional aerobic animal ICU
  • Extra-large space
  • Dual operation window
  • Natural phototherapy
  • Exclusive parking spot
  • Continuous monitoring
  • Biological status light
  • Unmanned power outage protection
  • Independent split type refrigeration
  • Intelligent automated printer
  • UVC ultraviolet sterilization
  • Open oxygen transfer
  • Circulation ventilation
  • Medical examination lamp
  • Simulated ecological sunlight lamp
  • Medical Blue Light
  • Emergency ventilation switch
  • Emergency operation window
  • CO2 purification
  • CO2 alarm
  • 3D Constant Temperature
  • 3D Constant Oxygen
  • Air pressure atomization
  • Sleeping curtain
  • Sodium lime
  • Medical oxygen hose
  • High flow oxygen generator (optional selection)
  • 24/7 monitoring: Real time monitoring is carried out through monitoring equipment to ensure the safety and stability of treatment.
  • CO2 emission: When the CO2 index reaches a certain value, it will automatically start discharging.
  • Aseptic therapy: High oxygen aseptic therapy, infrared therapy, to enhance treatment effectiveness.
  • Constant temperature and humidity: creating a stable temperature and humidity environment, providing a comfortable treatment and rehabilitation environment.
  • Multiple purification: negative ion purification and ultraviolet disinfection to prevent cross infection.
  • Easy to operate: Simplified operation process, easy to use and manage.
  • Durable materials: Choose durable materials, reject inferior materials, and ensure stability and safety.
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for HICU-05

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

HICU-05 Pet ICU Monitor product datasheet

Public PDF

HQS datasheet for the HICU-05: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
HICU-05
Length
4 pages
File
PDF · 396 KB
Web copy prepared
Need a different language or configuration-specific document?

Pet ICU Monitor Specifications

Specification
Value
External dimensions Length
1000
depth
710
height
1600
Max Power consumption
1.6kw
Weight
236KG
Average power consumption
0.8KW
Power Supply
AC100V/220V 50/60HZ (with grounding)
Power outage guarantee
With program control
Air conditioning method
Independent split refrigeration/ PTC heating
Negative ion medical purification function
(7.2X10Pcs/cm3X4)
High concentration negative ions
Greening air function
UV sterilization lamp
UVC band 253nm
Temperature control accuracy
±0.5 °C
Setting temperature
15 - 38 ° C
Set oxygen concentration
21~60%, control accuracy ±1%
Blue light medical system
Blue 415nm LED
Carbon dioxide concentration
Monitor and clear 300 - 5000PPM, Error margin of 10PPM
Medical Nebulizer
Maximum atomization rate=0.2ml/min, Mist particles (0.5 - 2um)
Noise
≤ 40dB (A)
Alert and Warning
Abnormal O2 concentration, abnormal temperature Abnormal sensor and CO2 concentration Abnormal emergency hatch switch, etc
LED lighting board
Two way lighting control: warm light Adjustable control with ten levels of strength and weakness, medical Special cold light lamp for medical examination
Dehumidification index
The standard humidity is controlled within 40%, actual humidity control is less than 50%. Divided into three levels: High/ Middle/Low High: 45%~50% Middle : 40% - 44% Low :30%~39%
Fan control (Ventilation volume adjustment)
LOW/MIDDLE/HIGH
Oxygen input adjustment
low level
Temperature regulation
high level
Emergency ventilation start
high level
UV sterilization
mid-range
High CO2 concentration
high-end

Compare models in this series

Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.

ParameterHICU-01HICU-03HICU-05This model
Carbon dioxide concentration300 - 5000PPM, Error margin of 10PPM—Monitor and clear 300 - 5000PPM, Error margin of 10PPM
UV sterilizationUVC band 253nm—mid-range
External dimensionsLength 1400, depth 860, height 1900Length 1290, Depth 660, Height 1750—

Configuration

  • 8.4-inch touch color screen
  • Infusion stand
  • Micro printer
  • Intelligent automatic timed printing system
  • Built in medical CO2 high-efficiency purification agent And automatic CO2 removal device
  • Automatic dehumidification system

Options & accessories

  • High flow oxygen generator

Buyer decision support

HICU-05 procurement decision notes

HICU-05 is a single-patient pet ICU cabinet with temperature, oxygen, CO2 removal, nebulisation, blue-light and UV functions. Plan floor space, oxygen supply and power before ordering; for two patients in one cabinet, compare the dual-unit HICU-04.

Decision factorPublished for this modelConfirm before order
Cabinet size1000 × 710 × 1600 mm (L × D × H), 236 kg; dual operation windows plus emergency windowCheck the ward floor space, door widths on the delivery route and floor loading.
Climate control15–38 °C set range; independent split refrigeration with PTC heating; automatic dehumidification with three humidity levels (30–50 %)Confirm the ward temperature range; operating conditions are indoor −10 to 40 °C.
Oxygen21–60 % set range, ± 1 % control; medical oxygen hose included; high-flow oxygen generator optionalDecide whether you will connect a central/cylinder oxygen supply or order the optional generator.
CO2 handlingCO2 monitoring 300–5000 ppm (± 10 ppm), automatic CO2 removal, sodium lime absorbent, CO2 alarmAsk for the absorbent consumption rate and replacement source.
Therapy and hygieneNebuliser 0.2 ml/min; 415 nm blue LED; UVC 253 nm lamp; negative-ion purificationConfirm which functions your clinical team will use so staff training covers them.
Power and alarmsAC 100 V/220 V 50/60 Hz with grounding; 1.6 kW max, 0.8 kW average; alarms for O2, temperature, sensor, CO2 and emergency hatch; power-outage program control; micro-printerState the destination voltage and whether an external UPS is required for your site.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: specifications currently published for this model. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for HICU-05

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →