Syringe Pump
Introduction to Syringe Pump
The SP - 30 Syringe Pump is designed for precise and reliable fluid delivery in veterinary settings. It features an open system compatible with standard syringes, a large color LED display, and multiple operational modes for flexibility. Safety is enhanced with an anti-bolus system, audible and visual alarms, and accurate occlusion pressure detection.
Key Features of SP-30
- Large COLOR LED display
- KVO/Bolus function.
- Vertical & Horizontal mounting.
- Anti - bolus system to reduce significantly after occlusion sudden release.
- Three levels of Occlusion Pressure Alarm.
- Identify the specifications of syringe automatically.
- Audible and visual alarm: Syringe Holder Loose, Syringe Plunger Disengagement, Syringe Flange Insertion Error, Syringe Not Calibrated, Occlusion, Syringe Empty, Rate Abnormal, Battery Empty, No Battery, Key Holding During Infusion, Key Holding During Pause, Infusion Complete, Syringe Near Empty, No Action, Battery Low, Out of Flow Range
- Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions
- Power lost memory.
- Visual and audible alarm system and accurate injection rate make the process safer and reliable.
- Change the flow rate without stop during infusion.
Syringe Pump Specifications
PARAMETER | SPECIFICATION |
|---|---|
Applicable syringes | 5ml,10ml,20ml,30ml,50ml,60ml of any standard |
Accuracy | +/ - 2% with correct calibration |
Rate mode 50ml(60ml) | 0.1ml/h - 2000.0ml/h (0.1ml/h or 1ml/h step) |
30ml | 0.1ml/h - 1200.0ml/h (0.1ml/h or 1ml/h step) |
20ml | 0.1ml/h - 800.0ml/h (0.1ml/h or 1ml/h step) |
10ml | 0.1ml/h - 400.0ml/h (0.1ml/h or 1ml/h step) |
5ml | 0.1~200ml/h (0.1ml/h or 1ml/h step) |
Time Mode SOL. VOL | 0.1 - 9999.9ml (0.1ml step) |
TIME | 00:01 - 99:59min (1min step) |
Dose Mode Volume | 0.1 - 999.9ml (0.1ml step) |
DRUG MASS | 0.1 - 999.9mg 0.1mg step) |
DOSE | 0.001 - 9999ug/kg/min (0.001ug/kg/min step) |
WEIGHT | 0.1 - 300kg (0.1kg the least step) |
Dose unit | ng/kg/min, ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h, g/kg/h, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, U/h, IU/h, U/kg/h, ml/h |
Total Volume Range | 0.1 - 9999ml (0.1 ml step) |
Purge Rate 50ml(60ml) | 1500.0ml/h |
30ml | 1200.0ml/h |
20ml | 800.0ml/h |
10ml | 400.0ml/h |
5ml | 200ml/h |
KVO Rate | 3ml/h when the delivery rate ≥3ml/h, otherwise KVO is the actual delivery rate |
DPS dynamic pressure | Three levels setting Low (60± 15kPa), Medium (90± 15kPa), High (120± 15kPa) |
Alarms | Syringe Holder Loose, Syringe Plunger Disengagement, Syringe Flange Insertion Error, Syringe Not Calibrated, Occlusion, Syringe Empty, Rate Abnormal, Battery Empty, No Battery, Infusion Complete, Syringe Near Empty, No Action, Battery Low |
Three levels of alarm volume | LOW, MEDIUM or HIGH |
Bolus Rate 5ml | 0.1~200ml/h |
10ml | 0.1 - 400ml/h |
20ml | 0.1 - 800ml/h |
30ml | 0.1 - 1200ml/h |
50ml(60ml) | 0.1 - 2000ml/h |
Programmable and adjustable Bolus Volume Range | 1.0~50.0ml, (0.1ml step) |
Interface | RS - 232 |
Power source | AC power supply: AC 100 to 240V( +/ - 10%) , 50/60Hz; DC Power supply: 12~15V, power>15W; Built - in
Lithium
Battery: Rechargeable, 7.2V, 2600mAh. 8 - 10hours of continuous operation |
Protection Class | Class I, Type CF, IP34 |
Dimension / N.W | 240mm*150mm*117mm, 2.0kg |
Packing size/G.W | 300mm*260mm*160mm, 3.0KG |
Buyer decision support
SP-30 procurement decision notes
Treat syringe brand calibration, delivery range, occlusion settings, battery performance and mounting as configuration items, not generic pump assumptions.
| Decision factor | Published for this model | Confirm before order |
|---|---|---|
| Syringe compatibility | Standard 5, 10, 20, 30, 50 and 60 mL syringes listed | List the validated syringe brands/models and obtain the calibration procedure for each size. |
| Published accuracy | ±2% with correct calibration | Request the accuracy test method, flow-rate conditions, trumpet/startup data and recalibration interval. |
| Modes and rates | Rate, time and dose modes; maximum rate varies from 200 mL/h (5 mL) to 2,000 mL/h (50/60 mL) | Confirm required units, dose limits, bolus/KVO behavior and drug-library availability. |
| Occlusion settings | Low 60 ±15 kPa, medium 90 ±15 kPa, high 120 ±15 kPa | Confirm alarm delay, anti-bolus behavior and appropriate settings for the intended tubing and patient. |
| Power and interface | AC 100–240 V, DC 12–15 V, 7.2 V 2,600 mAh battery and RS-232 | Confirm battery runtime test conditions, mounting hardware, interface protocol and included power leads. |
Published-data limitations
- The brochure does not provide complete low-flow accuracy, startup-delay or interoperability evidence.
- Dose programming and alarm settings must follow the supplied instructions, trained-clinician workflow and local policy.
Prepared by HQS Medical Product Team · Documentation reviewed:
Source: SP-30 Syringe Pump model brochure (2 pages). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.
Visitor Reviews(0)
Submissions are moderated for spam. Purchase status is not independently verified.
Related Products
Write a Review
Submit only first-hand feedback. AI-generated, copied or incentivized reviews are not accepted.