Syringe Pump SP-30 - Syringe Pump | HQS Medical
Syringe Pump

Syringe Pump

Model: SP-30

Introduction to Syringe Pump

The SP - 30 Syringe Pump is designed for precise and reliable fluid delivery in veterinary settings. It features an open system compatible with standard syringes, a large color LED display, and multiple operational modes for flexibility. Safety is enhanced with an anti-bolus system, audible and visual alarms, and accurate occlusion pressure detection.

Key Features of SP-30

  • Large COLOR LED display
  • KVO/Bolus function.
  • Vertical & Horizontal mounting.
  • Anti - bolus system to reduce significantly after occlusion sudden release.
  • Three levels of Occlusion Pressure Alarm.
  • Identify the specifications of syringe automatically.
  • Audible and visual alarm: Syringe Holder Loose, Syringe Plunger Disengagement, Syringe Flange Insertion Error, Syringe Not Calibrated, Occlusion, Syringe Empty, Rate Abnormal, Battery Empty, No Battery, Key Holding During Infusion, Key Holding During Pause, Infusion Complete, Syringe Near Empty, No Action, Battery Low, Out of Flow Range
  • Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions
  • Power lost memory.
  • Visual and audible alarm system and accurate injection rate make the process safer and reliable.
  • Change the flow rate without stop during infusion.
Share:

Syringe Pump Specifications

PARAMETER
SPECIFICATION
Applicable syringes
5ml,10ml,20ml,30ml,50ml,60ml of any standard
Accuracy
+/ - 2% with correct calibration
Rate mode 50ml(60ml)
0.1ml/h - 2000.0ml/h (0.1ml/h or 1ml/h step)
30ml
0.1ml/h - 1200.0ml/h (0.1ml/h or 1ml/h step)
20ml
0.1ml/h - 800.0ml/h (0.1ml/h or 1ml/h step)
10ml
0.1ml/h - 400.0ml/h (0.1ml/h or 1ml/h step)
5ml
0.1~200ml/h (0.1ml/h or 1ml/h step)
Time Mode SOL. VOL
0.1 - 9999.9ml (0.1ml step)
TIME
00:01 - 99:59min (1min step)
Dose Mode Volume
0.1 - 999.9ml (0.1ml step)
DRUG MASS
0.1 - 999.9mg 0.1mg step)
DOSE
0.001 - 9999ug/kg/min (0.001ug/kg/min step)
WEIGHT
0.1 - 300kg (0.1kg the least step)
Dose unit
ng/kg/min, ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h, g/kg/h, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, U/h, IU/h, U/kg/h, ml/h
Total Volume Range
0.1 - 9999ml (0.1 ml step)
Purge Rate 50ml(60ml)
1500.0ml/h
30ml
1200.0ml/h
20ml
800.0ml/h
10ml
400.0ml/h
5ml
200ml/h
KVO Rate
3ml/h when the delivery rate ≥3ml/h, otherwise KVO is the actual delivery rate
DPS dynamic pressure
Three levels setting Low (60± 15kPa), Medium (90± 15kPa), High (120± 15kPa)
Alarms
Syringe Holder Loose, Syringe Plunger Disengagement, Syringe Flange Insertion Error, Syringe Not Calibrated, Occlusion, Syringe Empty, Rate Abnormal, Battery Empty, No Battery, Infusion Complete, Syringe Near Empty, No Action, Battery Low
Three levels of alarm volume
LOW, MEDIUM or HIGH
Bolus Rate 5ml
0.1~200ml/h
10ml
0.1 - 400ml/h
20ml
0.1 - 800ml/h
30ml
0.1 - 1200ml/h
50ml(60ml)
0.1 - 2000ml/h
Programmable and adjustable Bolus Volume Range
1.0~50.0ml, (0.1ml step)
Interface
RS - 232
Power source
AC power supply: AC 100 to 240V( +/ - 10%) , 50/60Hz; DC Power supply: 12~15V, power>15W; Built - in Lithium Battery: Rechargeable, 7.2V, 2600mAh. 8 - 10hours of continuous operation
Protection Class
Class I, Type CF, IP34
Dimension / N.W
240mm*150mm*117mm, 2.0kg
Packing size/G.W
300mm*260mm*160mm, 3.0KG

Buyer decision support

SP-30 procurement decision notes

Treat syringe brand calibration, delivery range, occlusion settings, battery performance and mounting as configuration items, not generic pump assumptions.

Decision factorPublished for this modelConfirm before order
Syringe compatibilityStandard 5, 10, 20, 30, 50 and 60 mL syringes listedList the validated syringe brands/models and obtain the calibration procedure for each size.
Published accuracy±2% with correct calibrationRequest the accuracy test method, flow-rate conditions, trumpet/startup data and recalibration interval.
Modes and ratesRate, time and dose modes; maximum rate varies from 200 mL/h (5 mL) to 2,000 mL/h (50/60 mL)Confirm required units, dose limits, bolus/KVO behavior and drug-library availability.
Occlusion settingsLow 60 ±15 kPa, medium 90 ±15 kPa, high 120 ±15 kPaConfirm alarm delay, anti-bolus behavior and appropriate settings for the intended tubing and patient.
Power and interfaceAC 100–240 V, DC 12–15 V, 7.2 V 2,600 mAh battery and RS-232Confirm battery runtime test conditions, mounting hardware, interface protocol and included power leads.

Published-data limitations

  • The brochure does not provide complete low-flow accuracy, startup-delay or interoperability evidence.
  • Dose programming and alarm settings must follow the supplied instructions, trained-clinician workflow and local policy.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: SP-30 Syringe Pump model brochure (2 pages). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Visitor Reviews(0)

Submissions are moderated for spam. Purchase status is not independently verified.

No reviews yet. Be the first to review this product!

Write a Review

Submit only first-hand feedback. AI-generated, copied or incentivized reviews are not accepted.