Dry Heat Sterilizer (Hot Air Sterilizer)
Introduction to Dry Heat Sterilizer (Hot Air Sterilizer)
The GRF series Dry Heat Sterilizer (Hot Air Sterilizer) is designed for drying, baking, and disinfection applications in industrial and mining enterprises, chemical laboratories, and R&D institutions. It features microprocessor PID temperature control for accuracy and reliability, a wide timing range, and an automatic saving system.
Key Features of GRF series
- Outer Shell Material: Cold - rolled steel sheet surface spray
- Inner Material: SUS304 Stainless steel
- Microprocessor PID temperature control, accurate and reliable
- Inner round cornered design, convenient to clean
- Inlet and outlet at back side
- Outer observation window and no glass inner door
- Stainless steel tube heater
Dry Heat Sterilizer (Hot Air Sterilizer) Specifications
Model | GRF-9023A | GRF-9053A | GRF-9073A | GRF-9123A | GRF-9203A |
|---|---|---|---|---|---|
Temperature Range | Room Temperature +10 º C - 250 º C | Room Temperature +10 º C - 250 º C | Room Temperature +10 º C - 250 º C | Room Temperature +10 º C - 250 º C | Room Temperature +10 º C - 250 º C |
Temperature Fluctuation | ± 1 ℃ | ± 1 ℃ | ± 1 ℃ | ± 1 ℃ | ± 1 ℃ |
Temperature Uniformity | ≤Max working temperature ±2.5% | ≤Max working temperature ±2.5% | ≤Max working temperature ±2.5% | ≤Max working temperature ±2.5% | ≤Max working temperature ±2.5% |
Inner Cyclic Mode | Forced convection | Forced convection | Forced convection | Forced convection | Forced convection |
Alarm Type | Over temperature alarm, Timing alarm and Temperature probe damage alarm | Over temperature alarm, Timing alarm and Temperature probe damage alarm | Over temperature alarm, Timing alarm and Temperature probe damage alarm | Over temperature alarm, Timing alarm and Temperature probe damage alarm | Over temperature alarm, Timing alarm and Temperature probe damage alarm |
Temperature Controller | LCD display and P.I.D. temperature controller | LCD display and P.I.D. temperature controller | LCD display and P.I.D. temperature controller | LCD display and P.I.D. temperature controller | LCD display and P.I.D. temperature controller |
Work Room Dimension WxDxH (cm) | 30*30*28 | 42*37*35 | 45*45*45 | 55*36*55 | 60*55*64.5 |
Capacity(L) | 25 | 54 | 91 | 108 | 212 |
Outline Dimension WxDxH (cm) | 58*50*45 | 71*56*53 | 74*64*63 | 83*61*72 | 88*74*82 |
Shelves | 2 | 2 | 2 | 2 | 2 |
Rated Power (W) | 650 | 1000 | 1500 | 1600 | 2450 |
Power | 1 Φ 220V 50Hz | 1 Φ 220V 50Hz | 1 Φ 220V 50Hz | 1 Φ 220V 50Hz | 1 Φ 220V 50Hz |
Customer Reviews(0)
Related Products

Ethylene Oxide Gas Sterilizer
Model: EO-HSeries

Ethylene Oxide Gas Sterilizer
Model: EO - H40

Digital Cassette Sterilizer
Model: N - 5L, N - 5L+

H2O2 Low Temperature Plasma Sterilizer
Model: HO-D100, D130, D220
Frequently Asked Questions (FAQ)
What are the key features of the Dry Heat Sterilizer (Hot Air Sterilizer)?
The Dry Heat Sterilizer (Hot Air Sterilizer) features Outer Shell Material: Cold - rolled steel sheet surface spray, Inner Material: SUS304 Stainless steel, Microprocessor PID temperature control, accurate and reliable. It is designed for professional veterinary use and meets international quality standards.
What types of veterinary clinics is the Dry Heat Sterilizer (Hot Air Sterilizer) suitable for?
The Dry Heat Sterilizer (Hot Air Sterilizer) is suitable for small animal clinics, large animal hospitals, emergency veterinary centers, and specialty practices. It can be configured to meet different clinical requirements.
What is the warranty period for this equipment?
All HQS Medical veterinary equipment comes with a standard 12-24 months warranty and lifetime technical support.
Do you offer global shipping?
Yes, we provide fast and secure shipping to over 50 countries worldwide, including all necessary customs documentation.