Color Doppler Ultrasound Scanner US-T5
Introduction — Color Doppler Ultrasound Scanner
The US-T5 Color Doppler Ultrasound Scanner is a high-performance diagnostic system featuring a Windows 8 operating system. It offers advanced imaging capabilities including Pulse Doppler Imaging (PW), Direction Power Doppler Imaging (DPDI), and real-time three-synchronous imaging for B/C/D modes. Enhanced by Compound Imaging and Tissue Harmonic Imaging (THI), the T5 provides superior image quality with flexible display modes like 2B/4B.
Key Features — US-T5
- Operating system: Windows 8 operating system
- Pulse Doppler Imaging (PW)
- Direction Power Doppler Imaging (DPDI)
- B/C/D Real - time Three Synchronous Imaging
- Compound Imaging
- Tissue Harmonic Imaging (THI)
- 2B/4B Imaging Modes
- System language option: Chinese, English, French, Russian, Spanish
- Main monitor: ≥ 21.5 inch
- Host build in 128G hard disk, start fast and stable.
- Movie playback: ≥600 frames.
- Report type: ≥6 .
- One key fast report graphic and text management .
- Image format: BMP, DCM, JPG .
- Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by number, check number, name and so on.
Color Doppler Ultrasound Scanner Specifications
PARAMETER | SPECIFICATION |
|---|---|
2D Imaging Mode Gain | 0 - 100, Step 1 adjustable |
TGC | 8 segment adjustable |
Dynamic | 20 - 280, 20 levels adjustable |
Pseudo color | 0 - 11, adjustable |
Sound power | 5% - 100%, step 5% adjustable |
Body mark | ≥ 18 kinds optional |
Maximum focus | ≥6, which can be moved throughout the whole process |
Grey scale map | 0 - 7, 7 levels adjustable |
Filter | 0 - 4 |
Scanning range | 50% - 100% |
Frame correlation | 0 - 4, 4 level adjustable |
Line density | low, middle, high, 3 levels adjustable |
Noise reduction | 0 - 14 , 4 level adjustable |
The screen has real - time display of sound power, probe frequency, dynamic range, pseudo color, gray scale and other 14 parameters can be adjusted. | |
Color Doppler Imaging Mode Color Frame correlation | 0 - 12, 12 levels adjustable |
Color map | 0 - 7 , 7 levels adjustable |
Color flip | adjustable |
Base line | 11 levels, adjustable |
Line density | low, high, 2 levels adjustable |
Filter | 0 - 5 levels adjustable |
B / C real - time split screen mode | |
Spectral Doppler Imaging Mode Sampling volume angle correction | - 80° ~ 80° adjustable |
Sample volume | 0.5mm - 20mm adjustable |
Frequency | 2 .5MHz, 3 .0MHz |
Base line | 11 levels, adjustable |
Pseudo color | 0 - 5 |
Parameter display | ≥4 kinds, adjustable |
Speed scale | 32.8–328 cm/s (different probes have different ranges) |
Spectrum envelope function | real time automatic spectrum envelope, manual spectrum envelope, and other. |
The system automatically analyses and displays various data such as PS, ED, RI, PI, S/D, HR, etc . | |
Grey map | 0 - 7 |
Filter | 0 - 8 |
Dynamic range | 10 - 95, step 5 |
Noise reduction | 0 - 28 |
Sound volume | 0 - 100 |
3D Imaging (optional) Fast angle supports | 0° , 90° , 180° , 270° rotation for 3D View |
Display mode | one image, two images, four images |
Reconstruction mode | Real Skin, Surface, Max, Min, X Rax |
Pseudo color | 0 - 7, 7 levels adjustable |
Zoom | 5 levels |
Contrast | 0% - 100% |
Threshold level | 0% - 100% |
Smooth | ≥3 levels |
Image rotation | X/Y/Z Axis |
Brightness | 0% - 100% |
4D Imaging (optional) Fast angle supports | 0° , 90° , 180° , 270° rotation for 3D View |
Display model | one image, two images, four images |
Reconstruction mode | Real Skin, Surface, Max, Min, X Rax |
Pseudo color | 0 - 7, 7 levels adjustable |
Zoom | 5 levels |
Contrast | 0% - 100% |
Threshold level | 0% - 100% |
Smooth | ≥3 levels, adjustable |
Image rotation | X/Y/Z Axis |
Line density | 2 levels, adjustable |
Measurement and Analysis General measurement | distance, area, angle, time, slope, heart rate, speed, acceleration, blood flow path, blood flow spectrum trace, resistance index/pulsation index, etc |
OB measurement data | Cannie, Feline, Bovine, Ovine, Equine |
Measurement line color and type can be adjusted at will (including the activation color and the completion color) | |
Measurement result display position and font size can be adjusted as needed | |
Professional data package | Abdomen, OB, Urology, etc |
Various Probes Convex probe (detecting depth: 30 - 255mm) Fundamental Frequency | 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz
Harmonic
Frequency: H4.0MHz/ H5.0MHz |
Linear probe (detecting depth: 20 - 128mm) Fundamental Frequency | 6.0MHz/ 7.5MHz/ 8.5MHz/ 10.0MHz
Harmonic
Frequency: H10.0MHz |
Rectal probe (detecting depth: 30 - 156mm) Fundamental Frequency | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic
Frequency: H8.0MHz |
Phased array probe (detecting depth: 100 - 244mm) Fundamental Frequency | 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz
Harmonic
Frequency: H3.0MHz/ H4.0MHz |
4D volume probe (detecting depth: 30 - 237mm) Fundamental Frequency | 2.0MHz/ 3.0MHz/ 4.5MHz/ 6.0MHz
Harmonic
Frequency: H5.0MHz |
Micro - convex probe R15 (detecting depth: 30 - 111mm) Fundamental Frequency | 4.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz
Harmonic
Frequency: H8.0MHz |
Micro - convex probe R11 (detecting depth: 30 - 111mm) Fundamental Frequency | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic
Frequency: H8.0MHz |
Micro - convex probe R20 (detecting depth: 30 - 111mm) Fundamental Frequency | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz
Harmonic
Frequency: H8.0MHz |
Compare models in this series
Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.
This model belongs to the US-P60 series. The series overview lists every model side by side. Open series overview
| Parameter | US-E80 | US-L6 | US-P60 | US-T5This model |
|---|---|---|---|---|
| Pseudo color | — | 0 - 12, adjustable | — | 0 - 11, adjustable |
| Noise reduction | — | 0 - 14 | — | 0 - 14 , 4 level adjustable |
| Color map | — | 0 - 3, 3 levels adjustable | — | 0 - 7 , 7 levels adjustable |
| Frequency | — | 4.5MHz, 6.0MHz | — | 2 .5MHz, 3 .0MHz |
| Speed scale | — | 3 - 2288cm/s (different probes have different ranges) | — | 32.8–328 cm/s (different probes have different ranges) |
| Spectrum envelope function | — | real time automatic spectrum envelope, manual spectrum envelope, and other. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, HR, ACC, etc | — | real time automatic spectrum envelope, manual spectrum envelope, and other. |
| Display mode | B, B+B, B+M, M, 4B | — | — | one image, two images, four images |
| Zoom | — | — | 1.5×, 2.0×, 2.5×, 3.0×, 3.5×, 4.0×, 4.5×, 5.0× and 10× | 5 levels |
| Linear probe (detecting depth: 20 - 128mm) Fundamental Frequency | — | 6.0MHz/ 7.5MHz/ 8.5MHz/ 10.0MHz | — | 6.0MHz/ 7.5MHz/ 8.5MHz/ 10.0MHz Harmonic Frequency: H10.0MHz |
| Micro - convex probe R15 (detecting depth: 30 - 111mm) Fundamental Frequency | — | 4.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz | — | 4.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz Harmonic Frequency: H8.0MHz |
| Micro - convex probe R11 (detecting depth: 30 - 111mm) Fundamental Frequency | — | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz | — | 4.5MHz/ 6.0MHz/ 7.0MHz/ 9.0MHz Harmonic Frequency: H8.0MHz |
| Display | 15 - inch 1024*768 resolution high - definition L CD screen | — | 15-inch high-resolution medical LCD | — |
Options & accessories
- Video printer (optional)
- Laser printer (optional)
- Trolley
- 3D Imaging (optional)
- 4D Imaging (optional)
Warranty and after-sales service for US-T5
How HQS handles warranty, spare parts and repairs for this model.
- Warranty period
- The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
- What is covered
- A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
- Spare parts
- Spare parts and technical support are available for at least eight years from the date HQS ships the product.
- Response time
- Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
- Repairs in warranty
- If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
- Repairs after warranty
- HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.
Related Products

Color Doppler Ultrasound Scanner
Model: US-E80

Color Doppler Ultrasound Scanner
Model: US-L6

Color Doppler Ultrasound Scanner
Model: US-P60

Wireless Ultrasound Scanner
Model: US-3C/US-3L