Handheld Capnograph Monitor Capno-H - EtCO2 Monitor | HQS Medical
EtCO2 Monitor

Handheld Capnograph Monitor

Model: Capno-H

Introduction to Handheld Capnograph Monitor

The Capno-H Handheld Capnograph Monitor provides clear monitoring of EtCO2/CO2, respiration rate, and optional SpO2 and Pulse. It features HQS's EtCO2 technology with infrared ray gas analysis, a temperature and pressure compensation system, and zero readjustment for accuracy and stability. The device offers a 24-hour trend diagram, audio-optical alarms, and a 10-hour UPS battery backup.

Key Features of Capno-H

  • ARI's EtCO2 technology of infrared ray gas analysis
  • Temperature, Pressure compensation system and Zero readjustment system
  • Balance gas compensation makes minimum influence against other gases
  • KPA,mmHg or % are selectable
Share:

Handheld Capnograph Monitor Specifications

PARAMETER
SPECIFICATION
Measurement CO2 Unit
mmHg, kPa, % (selectable)
EtCO2 Update
Every Breath
Trend Length
24hours
CO2 Measurement Range
0~150mmHg
Accuracy
EtCO2 range 0 - 40mmHg± 2mmHg
EtCO2 range 41 - 70mmHg ± 5%
EtCO2 range 71 - 100mmHg± 8%
EtCO2 range 100 - 150mmHg± 10%
RR Measurement Range
3~150t/min
Accuracy
The bigger value of ±1% or± 1t/min
0~150mmHg Trend length
24 hours
Alarm Type
Visual and Audible Alarms
Alarm situations
Check adapter; No Adaptor; Apnea; Low battery; The value of ETCO2/RR exceeds the upper and lower alarm limits.
Apnea
Low battery;the value of ETCO2/PR exceeds the upper and lower alarm limits.
Oximetry Saturation Range
0 - 100%
Accuracy
± 3% when 50 - 69% ± 2% when 70 - 100%
Trend length
24 hours
Pulse Rage Range
30 - 250bpm
Accuracy
The bigger value of ± 2bpm or± 2%(reading) when 30 - 250bpm
Trend Length
24 hours
Power Voltage
AC100V - 250V,50Hz/60Hz
Battery
DC3.6V/3800mAh
AC Power Consumption
≤ 5VA
Battery working time
4 hours after fully charged
Degree of Protection
IPX32
Working temperature
5~40° C
Relative humidity
30 - 75% (non - condensing)
Atmospheric pressure
55~115kpa
Dimension Battery
Lithium battery, rechargeable.
Size
70cm(W)*160cm(H)*44cm(D)
Net Weight
400g (Lithium battery and adult adapter included)
Display
2.8 inch,color TFT.

Buyer decision support

Capno-H procurement decision notes

The buying decision depends on the CO₂ sampling configuration, optional parameters and the consumables required for the intended animal sizes and workflows.

Decision factorPublished for this modelConfirm before order
CO₂ range0–150 mmHgConfirm the applicable accuracy range and response specification for the ordered sampling configuration.
Displayed unitsmmHg, kPa or % selectableConfirm local protocol, alarm defaults and staff training requirements.
Trend storage24 hoursConfirm export method, file format and whether patient records can be transferred.
Additional monitoringSpO₂ and pulse are described as optionalConfirm which sensor, extension cable and animal-use accessories are included.
ConsumablesNot fully itemized on the public pageRequest a list of sampling lines, adapters, filters and replacement intervals.

Published-data limitations

  • Do not compare capnographs on range alone; sampling method, delay, moisture handling and accessory availability affect use.
  • Alarm settings and clinical interpretation must follow the clinic protocol and the supplied manual.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: Capno-H Handheld Capnograph Monitor model brochure (2 pages). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Visitor Reviews(0)

Submissions are moderated for spam. Purchase status is not independently verified.

No reviews yet. Be the first to review this product!

Write a Review

Submit only first-hand feedback. AI-generated, copied or incentivized reviews are not accepted.