Handheld Capnograph Monitor
Introduction to Handheld Capnograph Monitor
The Capno-H Handheld Capnograph Monitor provides clear monitoring of EtCO2/CO2, respiration rate, and optional SpO2 and Pulse. It features HQS's EtCO2 technology with infrared ray gas analysis, a temperature and pressure compensation system, and zero readjustment for accuracy and stability. The device offers a 24-hour trend diagram, audio-optical alarms, and a 10-hour UPS battery backup.
Key Features of Capno-H
- ARI's EtCO2 technology of infrared ray gas analysis
- Temperature, Pressure compensation system and Zero readjustment system
- Balance gas compensation makes minimum influence against other gases
- KPA,mmHg or % are selectable
Handheld Capnograph Monitor Specifications
PARAMETER | SPECIFICATION |
|---|---|
Measurement CO2 Unit | mmHg, kPa, % (selectable) |
EtCO2 Update | Every Breath |
Trend Length | 24hours |
CO2 Measurement Range | 0~150mmHg |
Accuracy | EtCO2 range 0 - 40mmHg± 2mmHg |
EtCO2 range 41 - 70mmHg ± 5% | |
EtCO2 range 71 - 100mmHg± 8% | |
EtCO2 range 100 - 150mmHg± 10% | |
RR Measurement Range | 3~150t/min |
Accuracy | The bigger value of ±1% or± 1t/min |
0~150mmHg Trend length | 24 hours |
Alarm Type | Visual and Audible Alarms |
Alarm situations | Check adapter; No Adaptor; Apnea; Low battery; The value of ETCO2/RR exceeds the upper and lower alarm limits. |
Apnea | Low battery;the value of ETCO2/PR exceeds the upper and lower alarm limits. |
Oximetry Saturation Range | 0 - 100% |
Accuracy | ± 3% when 50 - 69% ± 2% when 70 - 100% |
Trend length | 24 hours |
Pulse Rage Range | 30 - 250bpm |
Accuracy | The bigger value of ± 2bpm or± 2%(reading) when 30 - 250bpm |
Trend Length | 24 hours |
Power Voltage | AC100V - 250V,50Hz/60Hz |
Battery | DC3.6V/3800mAh |
AC Power Consumption | ≤ 5VA |
Battery working time | 4 hours after fully charged |
Degree of Protection | IPX32 |
Working temperature | 5~40° C |
Relative humidity | 30 - 75% (non - condensing) |
Atmospheric pressure | 55~115kpa |
Dimension Battery | Lithium battery, rechargeable. |
Size | 70cm(W)*160cm(H)*44cm(D) |
Net Weight | 400g (Lithium battery and adult adapter included) |
Display | 2.8 inch,color TFT. |
Buyer decision support
Capno-H procurement decision notes
The buying decision depends on the CO₂ sampling configuration, optional parameters and the consumables required for the intended animal sizes and workflows.
| Decision factor | Published for this model | Confirm before order |
|---|---|---|
| CO₂ range | 0–150 mmHg | Confirm the applicable accuracy range and response specification for the ordered sampling configuration. |
| Displayed units | mmHg, kPa or % selectable | Confirm local protocol, alarm defaults and staff training requirements. |
| Trend storage | 24 hours | Confirm export method, file format and whether patient records can be transferred. |
| Additional monitoring | SpO₂ and pulse are described as optional | Confirm which sensor, extension cable and animal-use accessories are included. |
| Consumables | Not fully itemized on the public page | Request a list of sampling lines, adapters, filters and replacement intervals. |
Published-data limitations
- Do not compare capnographs on range alone; sampling method, delay, moisture handling and accessory availability affect use.
- Alarm settings and clinical interpretation must follow the clinic protocol and the supplied manual.
Prepared by HQS Medical Product Team · Documentation reviewed:
Source: Capno-H Handheld Capnograph Monitor model brochure (2 pages). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.