The Capno-H Handheld Capnograph Monitor provides clear monitoring of EtCO2/CO2, respiration rate, and optional SpO2 and Pulse. It features HQS's EtCO2 technology with infrared ray gas analysis, a temperature and pressure compensation system, and zero readjustment for accuracy and stability. The device offers a 24-hour trend diagram, audio-optical alarms, and a 10-hour UPS battery backup.
Key Features of Capno - H
- ARI's EtCO2 technology of infrared ray gas analysis
- Temperature, Pressure compensation system and Zero readjustment system
- Balance gas compensation makes minimum influence against other gases
- KPA,mmHg or % are selectable
Handheld Capnograph Monitor Specifications
PARAMETER | SPECIFICATION |
|---|---|
Measurement CO2 Unit | mmHg, kPa, % (selectable) |
EtCO2 Update | Every Breath |
Trend Length | 24hours |
CO2 Measurement Range | 0~150mmHg |
Accuracy | EtCO2 range 0 - 40mmHg± 2mmHg |
EtCO2 range 41 - 70mmHg ± 5% | |
EtCO2 range 71 - 100mmHg± 8% | |
EtCO2 range 100 - 150mmHg± 10% | |
RR Measurement Range | 3~150t/min |
Accuracy | The bigger value of ±1% or± 1t/min |
0~150mmHg Trend length | 24 hours |
Alarm Type | Visual and Audible Alarms |
Alarm situations | Check adapter; No Adaptor; Apnea; Low battery; The value of ETCO2/RR exceeds the upper and lower alarm limits. |
Apnea | Low battery;the value of ETCO2/PR exceeds the upper and lower alarm limits. |
Oximetry Saturation Range | 0 - 100% |
Accuracy | ± 3% when 50 - 69% ± 2% when 70 - 100% |
Trend length | 24 hours |
Pulse Rage Range | 30 - 250bpm |
Accuracy | The bigger value of ± 2bpm or± 2%(reading) when 30 - 250bpm |
Trend Length | 24 hours |
Power Voltage | AC100V - 250V,50Hz/60Hz |
Battery | DC3.6V/3800mAh |
AC Power Consumption | ≤ 5VA |
Battery working time | 4 hours after fully charged |
Degree of Protection | IPX32 |
Working temperature | 5~40° C |
Relative humidity | 30 - 75% (non - condensing) |
Atmospheric pressure | 55~115kpa |
Dimension Battery | Lithium battery, rechargeable. |
Size | 70cm(W)*160cm(H)*44cm(D) |
Net Weight | 400g (Lithium battery and adult adapter included) |
Display | 2.8 inch,color TFT. |
Customer Reviews(0)
Related Products
Frequently Asked Questions (FAQ)
What are the key features of the Handheld Capnograph Monitor?
The Handheld Capnograph Monitor features ARI's EtCO2 technology of infrared ray gas analysis, Temperature, Pressure compensation system and Zero readjustment system, Balance gas compensation makes minimum influence against other gases. It is designed for professional veterinary use and meets international quality standards.
What types of veterinary clinics is the Handheld Capnograph Monitor suitable for?
The Handheld Capnograph Monitor is suitable for small animal clinics, large animal hospitals, emergency veterinary centers, and specialty practices. It can be configured to meet different clinical requirements.
What is the warranty period for this equipment?
All HQS Medical veterinary equipment comes with a standard 12-24 months warranty and lifetime technical support.
Do you offer global shipping?
Yes, we provide fast and secure shipping to over 50 countries worldwide, including all necessary customs documentation.