Multiparameter Monitor HM - 12V - Multiparameter Monitor | HQS Medical
Multiparameter Monitor

Multiparameter Monitor

Model: HM - 12V

Introduction to Multiparameter Monitor

The HM - 12V is a 12.1-inch multiparameter patient monitor designed for veterinary use. It offers comprehensive monitoring capabilities with six standard parameters: ECG, RESP, NIBP, SpO2, TEMP, and PR/HR. The monitor features advanced arrhythmia analysis, real-time ST segment monitoring, and efficient resistance to interference from defibrillators and electrosurgical devices. Its user-friendly interface, large storage capacity for trend data, and networking capabilities make it a versatile tool for critical care environments.

Key Features of HM - 12V

  • 12.1-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, TEMP, PR/HR
  • 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable
  • Efficient resistance to interference of defibrillator and electrosurgical cautery
  • SPO2 can testing for 0.1% Weak
  • Trend Coexist Display
  • OxyCRG DyNamic View Display
  • Bed to Bed view Display
  • Networking capacity and nurse calling system
  • Built - in rechargeable battery 4400mAh
  • Large volume of tabular and graphic trends information storage and easy to recall
  • Anti - ESU, anti - defibrillator
  • Capture dynamic waveforms
Share:

Multiparameter Monitor Specifications

Parameter
Value
ECG Lead Mode
5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
Lead selection
I, II, III, avR, avL, avF, V Waveform: 2 ch
Lead mode
3 Leads (R, L, F or RA, LA, LL)
Lead selection
I, II, III Waveform: 1 ch
Gain
‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
Heart Rate Range
15 ~ 300 bpm
Accuracy
±1% or ±1bpm, which great
Resolution
1 bpm
Sensitivity
>200 (uV P - P)
Differential Input Impedance
> 5 M Ω
CMRR - Monitor
> 105 dB
CMRR - Operation
> 105 dB
CMRR - Diagnosis
> 85 dB
Electrode offset potential
± 300mV
Leakage Current
<10uA
Baseline Recovery
< 3S after Defi.
ECG Signal Range
± 8 m V (Vp - p)
Bandwidth - Surgery
1 ~ 15 Hz
Bandwidth - Monitor
0.5 ~ 35 Hz
Bandwidth - Diagnostic
0.05 ~ 100 Hz
Calibration Signal
1 (mV p - p) Accuracy: ± 5%
ST Segment Monitoring Range
Measure and Alarm - 2.0 ~ +2.0 mV
ARR Detecting Type
ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm
Available
Review
Available
Respiration Method
Impedance between R - F (RA - LL)
Differential Input Impedance
>2.5 M Ω
Measuring Impedance Range
0.3 ~ 5.0 Ω
Base line Impedance Range
0 ~ 2.5 K Ω
Bandwidth
0.3 ~ 2.5 Hz
Resp. Measuring Range - Adult
0 ~ 120 rpm
Resp. Measuring Range - Neo/Ped
0 ~ 150 rpm
Resp. Alarm Range - High alarm range limit
8~120 rpm
Resp. Alarm Range - Low alarm range limit
6~120 rpm
Resolution
1 rpm
Accuracy
± 2 rpm
Apnea Alarm
10 ~ 40 S
NIBP Method
Oscillometric
Mode
Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode
5 Min
Pulse Rate Range
40 ~ 240 bpm
Alarm Type
SYS, DIA, MEAN
Measuring and alarm range - SYS
40 ~ 280 mmHg
Measuring and alarm range - DIA
10 ~ 225 mmHg
Measuring and alarm range - MEAN
20 ~ 240 mmHg
Resolution Pressure
1mmHg
Accuracy Pressure Maximum Mean error
± 5mmHg
Accuracy Pressure Maximum Standard deviation
± 8mmHg
SpO2 Measuring Range
0 ~ 100 %
SpO2 Alarm Range
0 ~ 100 %
Resolution
1 %
Accuracy
70% ~ 100% ± 2 % ; 0% ~ 69% unspecified
Actualization interval
about 1 Sec.
Alarm Delay
10 Sec.
Pulse Rate Measuring and Alarm Range
20~250bpm
Resolution
1bpm
Accuracy
± 3bpm
Temperature Measuring and Alarm Range
0 ~ 50° C
Resolution
0.1° C
Accuracy
± 0.1° C
Actualization interval
about 1 Sec.
Average Time Constant
<10 Sec.
IBP (optional) Label
ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range - ART
0 ~ 300 mmHg
Measuring and alarm range - PA
- 6 ~ 120 mmHg
Measuring and alarm range - CVP/RAP/LAP/ICP
- 10 ~ 40 mmHg
Measuring and alarm range - P1/P2
- 10 ~ 300 mmHg
Press Sensor Sensitivity
5uV/V/mmHg
Impedance
300 - 3000 Ω
Resolution
1 mmHg
Accuracy
± 2% or ± 1mmHg, which great
Actualization interval
about 1 Sec.

Customer Reviews(0)

No reviews yet. Be the first to review this product!

Frequently Asked Questions (FAQ)

What are the key features of the Multiparameter Monitor?

The Multiparameter Monitor features 12.1-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, TEMP, PR/HR, 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable, Efficient resistance to interference of defibrillator and electrosurgical cautery. It is designed for professional veterinary use and meets international quality standards.

What types of veterinary clinics is the Multiparameter Monitor suitable for?

The Multiparameter Monitor is suitable for small animal clinics, large animal hospitals, emergency veterinary centers, and specialty practices. It can be configured to meet different clinical requirements.

What is the warranty period for this equipment?

All HQS Medical veterinary equipment comes with a standard 12-24 months warranty and lifetime technical support.

Do you offer global shipping?

Yes, we provide fast and secure shipping to over 50 countries worldwide, including all necessary customs documentation.

Write a Review