Mini Veterinary Monitor HM-3T - Multiparameter Monitor | HQS Medical
Multiparameter Monitor

Mini Veterinary Monitor HM-3T

Model: HM-3T

Introduction — Mini Veterinary Monitor

The HM-3T Mini Veterinary Monitor is the world's smallest and most compact vital signs monitor, designed for accurate measurements in various environments, including neonatal and shock patients. It features revolutionary movement compensation technology, a user-friendly 3.5-inch color TFT display, and supports up to 100 user IDs with extensive data storage capabilities for both monitoring and spot modes. The monitor offers audible and visual alarms with adjustable limits and is powered by a rechargeable lithium-ion battery.

Key Features — HM-3T

  • Smallest most compact vital signs monitor footprint in the world
  • Accurate Perfusion Index PI.= 0.05%
  • Revolutionary, advanced movement compensation
  • Accurate measurement in all kind of extreme environment measurement such as neonatal and shock patients
  • NIBP adopts SAWAA(Self - Adaptive - Waveform - Amplitude - adjustment) and SAFD (Self - Adaptive - Fast - Deflation) algorithms
  • Easy operation by 3.5' color TFT
  • Up to 100 users lD switch
  • M3T=SpO2 +NIBP + TEMP
  • Data storage capabilities
  • Historical data view, trend graph view
  • Monitoring mode - continuous recording, 48 hours of measurement data
  • Spot mode - 100 user ID's, each user can store 200 data sets
  • Audible and visual alarms, with upper and lower alarm limit adjustment
  • Trace 1 plethysmogram waveform
  • Alarm Probe off, low power
  • Application for Big and small animals
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for HM-3T

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

HM-3T Mini Veterinary Monitor product datasheet

Public PDF

HQS datasheet for the HM-3T: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
HM-3T
Length
3 pages
File
PDF · 390 KB
Web copy prepared
Need a different language or configuration-specific document?

Mini Veterinary Monitor Specifications

PARAMETER
SPECIFICATION
Display
3.5’’col or TFT
Resolution
320*480
Indicator
Alarm indicator, Power indicator
Modes
Visual and Audio
NIBP Wide NlBP measuring range Big Animal
40 - 270mmHg
NIBP Wide NlBP measuring range Small Animal
40~200mmHg
NIBP MEAN Big Animal
20 - 230mmHg
NIBP MEAN Small Animal
20~165mmHg
NIBP DIA Big Animal
10~210mmHg
NIBP DIA Small Animal
10~150mmHg
Pulse rate range
40 - 240bpm
NBP measur ing accuracy
± 3mmHg
Pulse rate measur ing accuracy
<=2% (>=100 BPM) or 2 beats/min(<100 BPM)
Independent software protection pressure Big animal
300mmHg
Independent software protection pressure Small animal
300mmHg
Independent hardware protection pressure Big animal
320 - 330mmHg
Independent hardware protection pressure Small animal
320 - 330mmHg
SpO2 Measure range SpO2
0 - 100%
SpO2 Measure range PR
0 - 500bpm
SpO2 Measure range Perfusion index
0.05% - 20%
Accuracy range SpO2 saturation
70 - 100%
Accuracy range Pulse range
20 - 500BPM
Accuracy range Perfusion index
0.025% - 20%
Measurement accuracy SpO2 Big animal(including pediatric)
+2 digit (70 - 100%),not defined ( < 70%)
Measurement accuracy SpO2 Small animal
+3 digit ,not defined ( < 70%)
Measurement accuracy SpO2 On motion condition
+3 digit
Measurement accuracy PR Big small animal (including pediatric)
+3 digit
Measurement accuracy PR On motion condition
+3 digit
Temperature Measurement range
25 - 45° C
Temperature Resolution
0.1 ° C
Temperature Accuracy
0.1 ° C
Power Type
Lithium ion battery
Operation time
8 hours for normal operation
Temperature: Operating
0 ° C - 45° C
Temperature: Storage/Transportation
-20 ° C - 65° C
Humidity: Operating
15% to 90% noncondensing
Humidity: Storage
0% to 95% noncondensing
Altitude Operating Altitude
Up to 5000 meters
Size Dimension
146mm*67mm*30mm
Weight
250g

Options & accessories

  • Charging docking station

Buyer decision support

HM-3T mini veterinary monitor procurement decision notes

The HM-3T is a handheld veterinary vital signs monitor measuring SpO2, NIBP and temperature, for big and small animals. It has a 3.5-inch 320 × 480 colour TFT screen showing one plethysmogram trace, measures 146 × 67 × 30 mm, weighs 250 g and runs about 8 hours on its lithium-ion battery; a charging dock is optional. NIBP covers systolic 40–270 mmHg in big animals and 40–200 mmHg in small animals with ±3 mmHg accuracy and pulse rate 40–240 bpm, with software over-pressure protection at 300 mmHg and hardware protection at 320–330 mmHg. SpO2 measures 0–100% (accuracy defined for 70–100%), pulse rate 0–500 bpm and perfusion index 0.05–20%. Temperature reads 25–45 °C with 0.1 °C resolution. It works in spot mode (100 user IDs, 200 data sets each) or monitoring mode (48 hours of continuous recording), with trend and history views and adjustable audible and visual alarm limits. Choose it for spot checks, recovery rounds and transport; for ECG, EtCO2 or multiple waveforms on one screen, compare the HQS bedside multiparameter monitors.

Decision factorPublished for this modelConfirm before order
NIBPSYS 40–270 mmHg (big animal) / 40–200 mmHg (small animal); MEAN 20–230 / 20–165 mmHg; DIA 10–210 / 10–150 mmHg; accuracy ±3 mmHg; pulse rate 40–240 bpm; protection pressure 300 mmHg (software), 320–330 mmHg (hardware)Tell us the animal sizes you monitor so we can confirm the cuff sizes to include.
SpO2 and perfusion indexSpO2 0–100% (accuracy range 70–100%; big animal 2 digits, small animal and in motion 3 digits); pulse rate 0–500 bpm; perfusion index 0.05–20%Ask which SpO2 sensor types (clip, wrap or tongue) are supplied for your species.
Temperature25–45 °C; resolution 0.1 °C; accuracy 0.1 °CAsk whether a rectal or surface probe is included.
Data, alarms and display3.5-inch colour TFT, 320 × 480; 1 plethysmogram trace; spot mode 100 user IDs × 200 data sets; monitoring mode 48 hours continuous recording; trend graph and history view; audible and visual alarms with adjustable limits; probe-off and low-power alarmsAsk how stored records can be exported if you need them in a patient file.
Battery and sizeLithium-ion battery; about 8 hours normal operation; optional charging dock; 146 × 67 × 30 mm; 250 g; operating 0–45 °C, 15–90% RH; altitude up to 5000 mSay whether you want the charging dock and give your plug type for the charger.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: HM-3T Mini Veterinary Monitor model brochure. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for HM-3T

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →