Introduction — Multiparameter Monitor
The HM - 200V Multiparameter Monitor features a 7-inch high-resolution color LCD display and is specifically designed for veterinary use with large measuring ranges for SpO2, pulse rate, and NIBP. It is widely adopted in pet hospitals and animal clinics.
Key Features — HM-200V
- Special designed logo for veterinary use only
- Variety accessories for veterinary application
- Widely used in pet hospitals and animal clinics etc
Get the price list by email
Share:
Multiparameter Monitor Specifications
Specification | Value |
|---|---|
ECG Lead mode | 5 lead,RA,LA,RL,LL,V |
Lead selection | I,II, III,V, AVF,AVL,AVR |
ECG waveform | 1 or 3 channels |
Gain selection | ×1/4, ×1/2, ×1, ×2, ×4, auto |
Sweep speed | 6.25mm/s,12.5mm/s,25mm/s,50mm/s |
Heart rate range | 20 - 350BPM |
Accuracy | ± 2BPM or ± 2% (whichever is greater) |
Resolution | 1BPM |
S - T deletion | Yes |
NIBP Method | Oscillometric with step - down deflation |
Range of systolic | 40 to 270mmHg |
Range of mean arterial | 30 to 220mmHg |
Range of diastolic | 20 to 200mmHg |
Measurement time | 30 to 50 seconds typical , 120 seconds maximum |
Alarm range | 20 - 260 (in 1mmHg steps), and OFF |
Temperature Channel | Two |
Measuring range | 25 - 45° |
Accuracy | ± 0.2° C, plus the temperature sensor tolerance |
Resolution | 0.1° C |
SPO2 Range | 0 - 100% |
Accuracy | ± 2 at 70 - 100% |
Resolution | 1% |
Range of pulse rate | 20 - 350BPM |
Resolution | 1BPM |
Respiration Measurement range | 0 - 120rpm |
Accuracy | ± 1rpm |
Resolution | 1rpm |
CO2 (Optional) Range | 0 - 150mmHg |
Accuracy | 0-40 mmHg: ± 2 mmHg; 41-150 mmHg: ± 10% of reading |
Range of Respiration | 2 - 150rpm |
Accuracy | ± 1%rpm |
Preheating time | 10s |
Power | AC input:100 to 240v, 50/60Hz |
Environmental Temperature | - 40 to 75° C(Storage) |
Operating Temperature | 0 to 50° C(Operating) |
Humidity | 15 to 95% (Operating) |
Storage Humidity | 10 to 95% (Storage) |
Battery Full charging time | 3 hours |
Operating time | approx. 4.5 hours |
Power consumption | 80VA |
Dimension Length | 300mm (11.81 inches) |
Width | 180mm (7.09 inches) |
Height | 129mm (5.08 inches) |
Weight | 2.05 kg (4.52 lbs) |
Compare models in this series
Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.
This model belongs to the HM-12V series. The series overview lists every model side by side. Open series overview
| Parameter | HM-8V | HM-12V | HM-200VThis model | HM-500V |
|---|---|---|---|---|
| ECG Lead mode | 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V) | 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V) | 5 lead,RA,LA,RL,LL,V | 5 lead,RA,LA,RL,LL,V |
| Lead selection | I, II, III, avR, avL, avF, V | I, II, III, avR, avL, avF, V, Waveform: 2 ch | I,II, III,V, AVF,AVL,AVR | I,II, III,V, AVF,AVL,AVR |
| Heart rate range | 15 ~ 300 bpm | 15 ~ 300 bpm | 20 - 350BPM | 25 - 350BPM |
| Accuracy | ±1% or ±1bpm, which great | ±1% or ±1bpm, which great | ± 2BPM or ± 2% (whichever is greater) | ± 2BPM or ± 2% (whichever is greater) |
| NIBP Method | Oscillometric | Oscillometric | Oscillometric with step - down deflation | Oscillometric with step - down deflation |
| Measurement time | — | — | 30 to 50 seconds typical , 120 seconds maximum | 30 to 50 seconds typical , 180 seconds maximum |
| Measuring range | — | — | 25 - 45° | 0 - 50° C |
| Range of pulse rate | — | — | 20 - 350BPM | 25 - 350BPM |
| Respiration Measurement range | — | — | 0 - 120rpm | 0 - 130rpm |
| Width | — | — | 180mm (7.09 inches) | 324 mm ( 12.76 inches) |
| Height | — | — | 129mm (5.08 inches) | 324 mm ( 12.76 inches) |
| Weight | — | — | 2.05 kg (4.52 lbs) | 3.75 kg (8.27 lbs) |
| Calibration Signal | 1 (mV p - p) | 1 (mV p - p), Accuracy: ± 5% | — | — |
Options & accessories
- CO2 (Optional)
Warranty and after-sales service for HM-200V
How HQS handles warranty, spare parts and repairs for this model.
- Warranty period
- The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
- What is covered
- A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
- Spare parts
- Spare parts and technical support are available for at least eight years from the date HQS ships the product.
- Response time
- Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
- Repairs in warranty
- If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
- Repairs after warranty
- HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.