The HM - 200V Multiparameter Monitor features a 7-inch high-resolution color LCD display and is specifically designed for veterinary use with large measuring ranges for SpO2, pulse rate, and NIBP. It is widely adopted in pet hospitals and animal clinics.

Key Features — HM-200V

  • Special designed logo for veterinary use only
  • Variety accessories for veterinary application
  • Widely used in pet hospitals and animal clinics etc
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Multiparameter Monitor Specifications

Specification
Value
ECG Lead mode
5 lead,RA,LA,RL,LL,V
Lead selection
I,II, III,V, AVF,AVL,AVR
ECG waveform
1 or 3 channels
Gain selection
×1/4, ×1/2, ×1, ×2, ×4, auto
Sweep speed
6.25mm/s,12.5mm/s,25mm/s,50mm/s
Heart rate range
20 - 350BPM
Accuracy
± 2BPM or ± 2% (whichever is greater)
Resolution
1BPM
S - T deletion
Yes
NIBP Method
Oscillometric with step - down deflation
Range of systolic
40 to 270mmHg
Range of mean arterial
30 to 220mmHg
Range of diastolic
20 to 200mmHg
Measurement time
30 to 50 seconds typical , 120 seconds maximum
Alarm range
20 - 260 (in 1mmHg steps), and OFF
Temperature Channel
Two
Measuring range
25 - 45°
Accuracy
± 0.2° C, plus the temperature sensor tolerance
Resolution
0.1° C
SPO2 Range
0 - 100%
Accuracy
± 2 at 70 - 100%
Resolution
1%
Range of pulse rate
20 - 350BPM
Resolution
1BPM
Respiration Measurement range
0 - 120rpm
Accuracy
± 1rpm
Resolution
1rpm
CO2 (Optional) Range
0 - 150mmHg
Accuracy
0-40 mmHg: ± 2 mmHg; 41-150 mmHg: ± 10% of reading
Range of Respiration
2 - 150rpm
Accuracy
± 1%rpm
Preheating time
10s
Power
AC input:100 to 240v, 50/60Hz
Environmental Temperature
- 40 to 75° C(Storage)
Operating Temperature
0 to 50° C(Operating)
Humidity
15 to 95% (Operating)
Storage Humidity
10 to 95% (Storage)
Battery Full charging time
3 hours
Operating time
approx. 4.5 hours
Power consumption
80VA
Dimension Length
300mm (11.81 inches)
Width
180mm (7.09 inches)
Height
129mm (5.08 inches)
Weight
2.05 kg (4.52 lbs)

Compare models in this series

Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.

This model belongs to the HM-12V series. The series overview lists every model side by side. Open series overview

ParameterHM-8VHM-12VHM-200VThis modelHM-500V
ECG Lead mode5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)5 lead,RA,LA,RL,LL,V5 lead,RA,LA,RL,LL,V
Lead selectionI, II, III, avR, avL, avF, VI, II, III, avR, avL, avF, V, Waveform: 2 chI,II, III,V, AVF,AVL,AVRI,II, III,V, AVF,AVL,AVR
Heart rate range15 ~ 300 bpm15 ~ 300 bpm20 - 350BPM25 - 350BPM
Accuracy±1% or ±1bpm, which great±1% or ±1bpm, which great± 2BPM or ± 2% (whichever is greater)± 2BPM or ± 2% (whichever is greater)
NIBP MethodOscillometricOscillometricOscillometric with step - down deflationOscillometric with step - down deflation
Measurement time——30 to 50 seconds typical , 120 seconds maximum30 to 50 seconds typical , 180 seconds maximum
Measuring range——25 - 45°0 - 50° C
Range of pulse rate——20 - 350BPM25 - 350BPM
Respiration Measurement range——0 - 120rpm0 - 130rpm
Width——180mm (7.09 inches)324 mm ( 12.76 inches)
Height——129mm (5.08 inches)324 mm ( 12.76 inches)
Weight——2.05 kg (4.52 lbs)3.75 kg (8.27 lbs)
Calibration Signal1 (mV p - p)1 (mV p - p), Accuracy: ± 5%——

Options & accessories

  • CO2 (Optional)

Warranty and after-sales service for HM-200V

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.