Ultra Sonic Scalpel System USS-200 - Ultrasonic Scalpel | HQS Medical
Ultrasonic Scalpel

Ultra Sonic Scalpel System

Model: USS-200

Introduction to Ultra Sonic Scalpel System

The USS-200 Rebirth Knife is an advanced ultrasonic scalpel system designed for veterinary surgical procedures. Utilizing ultrasonic cavitation and high-frequency mechanical vibration, it effectively cuts, cleans, and coagulates tissue. With three distinct functional scalpels suitable for both laparoscopic and open surgeries, this system offers precise and efficient tissue manipulation for a wide range of veterinary applications.

Key Features of USS-200

  • Suitable for laparoscopic and open surgery in all types of animal medical facilities.
  • Applicable to 95% of veterinary surgeries including Hepatobiliary, Head and Neck, Breast, Urinary, Thoracic, Gastrointestinal, Ophthalmic, ENT, Minimally invasive, and Sterilization Procedures.
  • Strong Anti-adhesion properties with low operating temperatures, avoiding eschar or carbonization.
  • Adjustable Operating Speed with five adjustable cutting speeds, resulting in low lateral thermal damage.
  • Clear Vision provided by a curved jaw design with a larger viewing area and less smoke during surgery.
  • Stable and Reliable performance with no current passing through the animal and stable energy output for coagulating blood vessels under 5mm.
  • High Flexibility with a 360° operating angle.
  • Easy to Care due to a blade diameter of only 5.5mm, enabling minimally invasive surgery with small incisions and quick recovery.
  • Compact and Lightweight design, weighing only 2.85KG and occupying little surgical space.
  • Tissue Pad made of PTFE, passed biocompatibility test, with an extremely dense serrated structure for enhanced grip and to avoid disengagement.
  • Cutting: Cutting of Bone and Tissue.
  • Cleaning: Excision and Cleaning of polyps and Lesions.
  • Coagulation: Intracavitary and body surface coagulation of disseminated and intravascular haemorrhage.
Share:

Ultra Sonic Scalpel System Specifications

Parameter
Value
Frequency of Output
55.5kHz
Peak Power
45W
Cutter Head Diameter
5.5 mm
Cutting Gear Position
Grades 1 to 5
Weight of Generator
2.85 kg
Power Input
220V / 50Hz
Shock Protection Grade
CF - Type / Class I Instrument
Electric Shock Protection Grade
CF - Type
Types of Electric Shock Protection
Class l equipment
Main Power Input Voltage
220V
Frequency
50Hz
Power
200VA
Output Voltage
200VAC (peak)
Power
45w (peak)
Frequency
55.5KHz
Operating Conditions Temperature
10 °℃ to 30 ℃
Operating Conditions Humidity
30 - 70%, no condensation
Operating Conditions Atmospheric pressure range
70KPa - 106KPa
Transportation and Storage Conditions Temperature
- 20 ℃ to +55 ℃
Transportation and Storage Conditions Humidity
10 - 93%, no condensation
Transportation and Storage Conditions Atmospheric pressure range
70KPa - 106KPa
Lateral thermal damage range
less than 1.5mm

Buyer decision support

USS-200 procurement decision notes

Separate the generator specification, handpieces, blade set and supported indications so the quotation can be checked against the exact instructions for use.

Decision factorPublished for this modelConfirm before order
Generator output55.5 kHz frequency, 45 W peak power and five cutting levelsConfirm the generator revision, transducer compatibility and output verification procedure.
Instrument geometry5.5 mm cutter head; 14 cm, 23 cm and 36 cm scalpel lengths listedList the exact shaft lengths, jaw types and quantities included in the quotation.
Published tissue claimsVessels up to 5 mm and lateral thermal damage below 1.5 mm are claimedRequest the model-specific indication, test method, evidence and instructions for use before relying on either figure.
Standard setGenerator, three scalpels, two transducers, sheaths, three Rebirth Knife types, wrench and foot pedal listedResolve the note that any three scalpel sizes may be selected and identify reusable versus single-use parts.
Electrical supply220 V, 50 Hz; generator weight 2.85 kgConfirm destination voltage/frequency, plug, electrical classification and service support.

Published-data limitations

  • The broad brochure statement that the system suits “95% of veterinary surgeries” is not used as a procurement claim.
  • Biocompatibility, vessel sealing, thermal spread and reprocessing statements require the underlying report and current instructions for use.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: USS-200 Ultrasonic Scalpel System model brochure (4 pages). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.