Veterinary Defibrillator
Introduction to Veterinary Defibrillator
The DEF - 8000C Veterinary Defibrillator is a versatile device designed for critical care in veterinary medicine. It offers multiple defibrillation modes, comprehensive patient monitoring capabilities including ECG, NIBP, Temperature, and SpO2, and a built-in recorder for detailed event logging. Its robust design and optional AED functionality make it a reliable tool for emergency situations.
Key Features of DEF-8000C
- Defibrillation type: Manual, Synchronized, Asynchronized
- Output waveform: Biphasic technology
- Charging time: Maximum 10 seconds to 360 Joule
- Reusable external paddles
- High resolution true-color graphic LED display
- ECG lead: I, II, III, AVR, AVL, AVF, V1 - V6, GND
- Arrhythmia analysis: yes
- Protection: Withstand 4000vAc/50Hz voltage in isolation and work against electrosurgical interfere and defibrillation
- NIBP Working mode: Manual/Automatic/stat (5 minutes)
- NIBP Method: Automatic oscillation
- Built-in Recorder: Paper: 50mm thermal.
- Printing Method: High - resolution, thermal print head.
- Record date, time sweep speed, waveform gain, heart rate, energy (joule) and ECG waveform
- Print mode: HR exceed limits alarm recording, Auto timed recording, Real - Time Recording, Defibrillation discharge trigger recording
Veterinary Defibrillator Specifications
Parameter | Value |
|---|---|
Defibrillation - Energy accuracy | <+1% |
Defibrillation - Energy selection | 0,3,5,7,10,20,30,50,100,200,300,3 60 Joule (Nominal at a resistance of 50) |
Power requirements - AC Power supply | 110V, 60 Hz /220V, 50 Hz |
Power requirements - Vehicle Voltage | DC 12V |
Internal Battery - Battery type | Rechargeable lithium battery |
Internal Battery - Charging time | Time - Minimum of 4 hours for full charging |
Internal Battery - Battery charging | During AC Power Supply operation of the device |
Internal Battery - Charging /Low Battery Indication | Red LED |
Internal Battery - Battery Capacity | 100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules |
Display - Dimensions | 7’diagonal {155mm*88mm} |
Display - Type | High resolution true - color graphic LED |
Display - Resolution | 480X234 |
NIBP Cuff type | standard Adult; optional Pediatric/Neonatal |
Temperature Measurement range | 20~45° C |
Temperature Resolution | 0.1° C |
SpO2 Range | 0~99%for adult, pediatric and neonatal patients |
Pulse Pulse range | 0 - 300 bpm |
Pulse Pulse accuracy | ± 2bpm |
Buyer decision support
DEF-8000C procurement decision notes
Defibrillation capability, animal-size accessories, monitoring parameters, battery performance, training and regulatory status must be verified as one emergency-care configuration.
| Decision factor | Published for this model | Confirm before order |
|---|---|---|
| Defibrillation | Manual, synchronized and asynchronous biphasic modes; 0–360 J selections listed | Confirm waveform, load range, charge time, paddles and intended veterinary use in the current instructions for use. |
| Monitoring package | ECG, NIBP, temperature, SpO₂, pulse and recorder listed as standard | List every lead, cuff, probe and recorder accessory included in the quoted package. |
| Animal-size accessories | Source describes an adult cuff/finger clip with pediatric/neonatal options | Obtain animal-specific cuff and sensor ranges; human age labels do not establish veterinary suitability. |
| Battery | 120 minutes monitoring and 30 discharges at 360 J claimed after full charge | Request battery test conditions, age/end-of-life criteria, replacement cost and periodic capacity-check procedure. |
| AED and power | AED energy programs are optional; 110 V 60 Hz, 220 V 50 Hz and DC 12 V listed | Confirm installed AED option, destination power configuration, operator training and local authorization requirements. |
Published-data limitations
- The notation “energy accuracy <+1%” is ambiguous and should not be repeated as a validated accuracy claim.
- The brochure does not provide a model-specific regulatory certificate, animal-use validation or complete AED/defibrillation protocol.
Prepared by HQS Medical Product Team · Documentation reviewed:
Source: DEF-8000C Veterinary Defibrillator model brochure (3 pages). Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.
Visitor Reviews(0)
Submissions are moderated for spam. Purchase status is not independently verified.
Related Products
Write a Review
Submit only first-hand feedback. AI-generated, copied or incentivized reviews are not accepted.