Veterinary Defibrillator
Introduction to Veterinary Defibrillator
The DEF - 8000C Veterinary Defibrillator is a versatile device designed for critical care in veterinary medicine. It offers multiple defibrillation modes, comprehensive patient monitoring capabilities including ECG, NIBP, Temperature, and SpO2, and a built-in recorder for detailed event logging. Its robust design and optional AED functionality make it a reliable tool for emergency situations.
Key Features of DEF - 8000C
- Defibrillation type: Manual, Synchronized, Asynchronized
- Output waveform: Biphasic technology
- Charging time: Maximum 10 seconds to 360 Joule
- Reusable external paddles
- High resolution true-color graphic LED display
- ECG lead: I, II, III, AVR, AVL, AVF, V1 - V6, GND
- Arrhythmia analysis: yes
- Protection: Withstand 4000vAc/50Hz voltage in isolation and work against electrosurgical interfere and defibrillation
- NIBP Working mode: Manual/Automatic/stat (5 minutes)
- NIBP Method: Automatic oscillation
- Built-in Recorder: Paper: 50mm thermal.
- Printing Method: High - resolution, thermal print head.
- Record date, time sweep speed, waveform gain, heart rate, energy (joule) and ECG waveform
- Print mode: HR exceed limits alarm recording, Auto timed recording, Real - Time Recording, Defibrillation discharge trigger recording
Veterinary Defibrillator Specifications
Parameter | Value |
|---|---|
Defibrillation - Energy accuracy | <+1% |
Defibrillation - Energy selection | 0,3,5,7,10,20,30,50,100,200,300,3 60 Joule (Nominal at a resistance of 50) |
Power requirements - AC Power supply | 110V, 60 Hz /220V, 50 Hz |
Power requirements - Vehicle Voltage | DC 12V |
Internal Battery - Battery type | Rechargeable lithium battery |
Internal Battery - Charging time | Time - Minimum of 4 hours for full charging |
Internal Battery - Battery charging | During AC Power Supply operation of the device |
Internal Battery - Charging /Low Battery Indication | Red LED |
Internal Battery - Battery Capacity | 100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules |
Display - Dimensions | 7’diagonal {155mm*88mm} |
Display - Type | High resolution true - color graphic LED |
Display - Resolution | 480X234 |
NIBP Cuff type | standard Adult; optional Pediatric/Neonatal |
Temperature Measurement range | 20~45° C |
Temperature Resolution | 0.1° C |
SpO2 Range | 0~99%for adult, pediatric and neonatal patients |
Pulse Pulse range | 0 - 300 bpm |
Pulse Pulse accuracy | ± 2bpm |
Customer Reviews(0)
Related Products
Frequently Asked Questions (FAQ)
What are the key features of the Veterinary Defibrillator?
The Veterinary Defibrillator features Defibrillation type: Manual, Synchronized, Asynchronized, Output waveform: Biphasic technology, Charging time: Maximum 10 seconds to 360 Joule. It is designed for professional veterinary use and meets international quality standards.
What types of veterinary clinics is the Veterinary Defibrillator suitable for?
The Veterinary Defibrillator is suitable for small animal clinics, large animal hospitals, emergency veterinary centers, and specialty practices. It can be configured to meet different clinical requirements.
What is the warranty period for this equipment?
All HQS Medical veterinary equipment comes with a standard 12-24 months warranty and lifetime technical support.
Do you offer global shipping?
Yes, we provide fast and secure shipping to over 50 countries worldwide, including all necessary customs documentation.