Veterinary Defibrillator DEF-8000D - Defibrillator | HQS Medical
Defibrillator

Veterinary Defibrillator

Model: DEF-8000D

Introduction to Veterinary Defibrillator

The DEF-8000D Veterinary Defibrillator is designed for critical cardiac care in veterinary settings. It offers both manual external synchronous and asynchronous defibrillation with a biphasic waveform. The device features a high-resolution display, rapid charging capabilities, and versatile power options, ensuring reliable performance during emergencies.

Key Features of DEF-8000D

  • Voice and visual charge prompts
  • Selectable energy levels from 0 to 360 joules
  • AC and DC dual-use power
  • ECG monitoring with 3-lead or 5-lead cable, or paddles
  • Protection against electrosurgical knife and defibrillation
  • Built-in thermal recorder for waveforms and data
  • HR exceed limits alarm recording
  • Auto timed recording
  • Real-time recording
  • Defibrillation discharge trigger recording
Share:

Veterinary Defibrillator Specifications

Parameter
Value
Defibrillation - Waveform
Biphasic
Defibrillation type
Manual External Synchronous/Asynchronous Defibrillation
Charge Time
Less than 10 seconds to 360 Joules
Energy Display
Monitor display indicates both selected and delivered energy
Charge Prompt Type
Voice and visual prompts
Energy Selection
Selectable at 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules
AC Power
100V ~ 240V, 50/60 Hz
Standard Battery Type
Li-ion battery Li1104c 11.1Vdc 4000mAh X2
Standard Battery Capacity
Up to 10 hours ECG monitoring or 60 full-energy discharges
Low Battery Indicator
Flashing low battery icon on display and Bat Indicator on the panel
Recharge Rate
80% in 3 hours. 100% in 5 hours.
Screen Type
High-resolution display
Screen Size
7 inches (17.7cm) diagonally
Sweep Speed
12.5/25/50mm/sec
Display Information
Heart Rate, Lead, Alarm On/Off, Delivered Energy
Resolution
480*272 pixel
ECG Patient Connection
3-lead ECG cable, or 5-lead ECG cable, paddles
ECG Lead Selection
Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V
ECG Size
2.5,5, 10, 20, 30 mm/mV display on monitor
Heart Rate Range
20 - 350 BPM
ECG Protection
Withstand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation
Recorder Paper
50mm thermal
Printing Method
High-resolution, thermal print head