The IP-50 Infusion Pump offers precise and reliable fluid delivery for veterinary applications. It features a user-friendly interface with a large, adjustable LCD display, manual or automatic bolus functions, and an anti-bolus system for enhanced safety. The pump stores up to 2000 events for easy review and download, ensuring comprehensive record-keeping.

Key Features — IP-50

  • Manual or Automatic Bolus/Purge/KVO function
  • Vertical & Horizontal mounting clamp
  • DPS dynamic pressure display
  • Anti - bolus system
  • Large LCD display with adjustable brightness
  • 2000 events stored can be checked/downloaded
  • Three levels of alarm volume: LOW, MEDIUM or HIGH
  • Purge Rate Programmable and adjustable
  • RS - 232 Interface
  • Brightness 1~10 levels can be selected
  • History records 2000 events stored can be checked and downloaded
  • Built - in Lithium Battery: Rechargeable, 11.1V, 2000mAh. 12 hours of continuous operation
  • Class I, Type CF, IPX4 Protection Class
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for IP-50

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Document status · English

IP-50 — configuration document package

Available on request

Request the current manual, datasheet and order-specific documents for this model. We will match the document set to the confirmed configuration, voltage and destination market.

  • Current user manual or instructions
  • Datasheet and ordered configuration
  • Packing list and accessories
  • Applicable compliance documents
  • Warranty and service terms
Need a different language or configuration-specific document?

Infusion Pump Specifications

PARAMETER
SPECIFICATION
Accuracy
+/ - 2%
Delivery Rate Range
0.1ml/h - 1200ml/h (0.1ml step)
Delivery Time Range
00h01min~99h59min (1 min step)
Volume Limit Range
0 .0 - 9999ml (1ml step)
Total Volume Range
0 .0 - 9999ml (1ml step)
Dose Mode
Volume: 0.1 - 999.9ml (0.1ml step) Drug Mass: 0.1 - 999.9mg (0.1mg step) Dose: 0.001 - 9999ug/kg/min (0.001ug/kg/min step) Weight: 0.1 - 300kg (0.1kg the least step)
KVO Rate
0 .0~5.0ml/h, Programmable and adjustable
DPS Occlusion Pressure
LOW: 60(± 15) kPa, MEDIUM: 90(± 15) kPa HIGH: 120(± 15) kPa (Adjustable)
Alarms
R ate abnormal, Air in line, Door open, Empty, Occlusion, Battery Empty, No Battery, Key Holding During Infusion/Pause, Infusion Complete, No Action, Battery Low
Bolus Function
B olus rate: 1.0~1200ml/h, Bolus volume: 1.0~100ml
Dimension / N.W.
120mm*100mm*215mm, 1.7kg
Packing size/G.W .
300mm*260mm*160mm, 2.5KG

Compare models in this series

Differences below are taken from the specifications published for each model. Confirm the final configuration in your quotation.

ParameterIP-50This modelIP-70
Accuracy+/ - 2%± 5%

Configuration

  • Fit IV tubes: Can be used with any brand IV set after exactly calibration
  • AC power supply: AC 100 to 240V( +/ - 10%) , 50/60Hz

Options & accessories

  • Drug Library Mode: 1030 kinds of drug names, makes drug dispensing more convenient and safer.
  • Sequential Mode

Buyer decision support

IP-50 / IP-70 infusion pump procurement decision notes

HQS lists two infusion pumps. The IP-50 has a large LCD with key control, a 0.1–1200 ml/h rate in 0.1 ml steps, ±2% accuracy, a dose mode by drug mass and body weight (0.1–300 kg), three DPS occlusion pressure levels, 2,000 stored events, an RS-232 interface and an 11.1 V 2,000 mAh battery for 12 hours of continuous operation. The IP-70 has a 4.3-inch colour touch screen, 0.01–1200 ml/h in 0.01 ml/h steps, ±5% accuracy, 12 occlusion levels, a drug library of at least 2,000 drugs, body-weight, drip, loading-dose, ramp and sequence modes, more than 5,000 history entries, mini USB with optional Wi-Fi, and a 2,600 mAh battery for more than 9 hours at 25 ml/h.

Decision factorPublished for this modelConfirm before order
Rate range and accuracyIP-50: 0.1–1200 ml/h (0.1 ml step), accuracy ±2%, delivery time 00h01min–99h59min, volume limit and total volume 0–9999 ml. IP-70: 0.01–1200 ml/h (0.01 ml/h increment), accuracy ±5%, VTBI 0–9999 mlAsk which infusion sets each pump is set up for and whether those sets are available in your market.
Infusion and dose modesIP-50: dose mode by volume 0.1–999.9 ml, drug mass 0.1–999.9 mg, dose 0.001–9999 µg/kg/min, weight 0.1–300 kg; bolus 1.0–1200 ml/h, 1.0–100 ml; manual or automatic bolus, purge and KVO; KVO 0–5.0 ml/h. IP-70: rate, time, body weight, drip, loading-dose, ramp up/down, sequence and drug library modes; bolus 0.1–1200 ml/h, automatic and manual; KVO 0.01–5 ml/h; titration without stopping the infusion; drug library of at least 2,000 drugsIf you want to use the IP-70 drug library, ask how entries are added or edited and in which languages the menus are available.
Occlusion pressure and alarmsIP-50: DPS occlusion pressure LOW 60, MEDIUM 90, HIGH 120 (± 15) kPa, anti-bolus system; alarms for abnormal rate, air in line, door open, empty, occlusion, battery empty / low, no battery, infusion complete and no action; three alarm volume levels. IP-70: 12 selectable occlusion levels, graphic and numeric pressure display, adjustable bubble detector, anti-bolus; alarms include pressure high, check upstream, air bubble, VTBI near end, door open and drop sensor connectionAsk whether a drop sensor is supplied with the IP-70 or quoted as an option.
Battery, power and dataIP-50: built-in rechargeable lithium battery 11.1 V 2,000 mAh, 12 hours continuous operation; RS-232 interface; 2,000 events stored, can be checked and downloaded. IP-70: lithium polymer battery 11.1 V 2,600 mAh, more than 9 hours at 25 ml/h, full charge in less than 5 hours; AC 110–240 V, 50/60 Hz; external DC 12 V; mini USB, Wi-Fi optional; more than 5,000 history entriesState your plug type, and ask whether Wi-Fi is included in the IP-70 quotation and how history records are exported.
Size, mounting and protectionIP-50: 120 × 100 × 215 mm, 1.7 kg; package 300 × 260 × 160 mm, 2.5 kg; vertical and horizontal mounting clamp; Class I, Type CF, IPX4. IP-70: 235 × 95 × 120 mm (L × W × H), approx. 1.6 kg; Class I, CF; IP24; relay mode on an infusion workstation (optional)Check the pole or rail size the clamp fits; ask about the infusion workstation if you plan to run several IP-70 pumps in sequence.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: specifications currently published for this model. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for IP-50

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.