H902-C Anesthesia Machine H902-C - Anaesthesia Machine | HQS Medical
Anaesthesia Machine

H902-C Anesthesia Machine

Model: H902-C

Introduction — H902-C Anesthesia Machine

The H 902 - C Anesthesia Machine is a manually operated, lightweight, and portable anesthesia delivery system designed for veterinary use. It features a high-strength module rack, a high-precision vaporizer compatible with various anesthetic agents, and a classical CO2 circle absorber for efficient gas management. The machine supports two gas sources (O2, N2O) and offers flexible ventilation modes for animals weighing between 2-100KG.

Key Features — H902-C

  • No electricity will be needed, only manual operation
  • Module rack with polyester medical material, high strength and light weight
  • Superior thin spray technology, delicate color, beautiful and durable
  • High precious vaporizer, Halothane, Enflurane, Isoflurane and Sevoflurane could be choosen freely
  • Main unit are only 2Kg (w/o vaporizer), light weight and easy to move
  • With a dedicated handle, could move by hand - pull
  • Two gas sources: O2, N2O, suitable for more patient type
  • Classical CO2 circle absorber with 1 canister, low resistance, minimum gas leakage, 60cmH2O peak pressure solution
  • Ventilator (Optional): TH - 1, TH - 1A
  • 3 types of Small Vaporizers and 4 types of Big Vaporizers for choice
  • Monitoring Airway pressure, respiratory mode
  • Three Gauges one for O2, one for N2O, one for airway pressure
  • Optional TH-1 / TH-1A ventilator: independent anesthesia ventilator with IPPV and manual modes
  • Optional ventilator: monitoring and alarm functions for operating safety
  • Optional ventilator drive gas: O2 or air
  • Optional ventilator: international connector, compatible with various brands of anesthesia machines
Get the price list by email

Leave your email and we'll send the quotation and datasheet for this model, usually within one working day.

Share:

Model-specific documentation

Documents for H902-C

Check the covered model, language and document status before use. The manual supplied with the actual unit remains the controlling reference.

Product datasheet · English

H902-C H902-C Anesthesia Machine product datasheet

Public PDF

HQS datasheet for the H902-C: product overview, features and the technical specifications published for this model. Confirm the ordered configuration in your quotation.

  • Product overview
  • Features
  • Technical specifications
Covered model
H902-C
Length
2 pages
File
PDF · 213 KB
Web copy prepared
Need a different language or configuration-specific document?

H902-C Anesthesia Machine Specifications

PARAMETER
SPECIFICATION
Ventilation mode
Closed, Semi - closed, Semi - open
Application
2 - 100KG animals
Gas source
O2, N2O 0.25Mpa~0.65Mpa
Two tube (O2, N2O) Scope
0 — 10L/min.With linkage device,O2 concentration not low than 25%
O2 flush
more than 25L/min
Respiratory mode
Manual (I:E set by the clinician)
Tidal volume (manual mode)
20–1500 mL
BPM
according to the doctor operation
APL Valve pressure
0.5 - 6KPa
Temperature Operation
18~36 º C
Storage
- 20~55 º C
Humidifier Operation
45%~75%
Storage
≤93%
Atmospheric pressure Operation
0.95~1.05 bar
Storage
500hPa~1060hPa
Altitude Operation
500 to 800mmHg (3565~ - 440m)
Storage
375 to 800mmHg (5860~ - 440m)

Configuration

  • TH - 1A Parameter - Respiration mode: IPPV, SIMV, Manual
  • TH - 1A - Respiratory frequency: 1 to 65BPM
  • TH - 1A - Display : 5.5´ SNT screen
  • TH - 1A - I:E ratio: 8:1~1:8
  • TH - 1A - Waveform: P - t, V - t
  • TH - 1A - Tidal volume: 50ml~1600ml
  • TH - 1A - Monitor Parameters: Tidal volume; Minute Ventilation; Peak
  • TH - 1 Parameter - Control method: Gas driving electronic controlled
  • TH - 1 - Breath frequency: 1~90BPM
  • TH - 1 - Display : High light LED display
  • TH - 1 - I:E ratio: 4:1~1:6
  • TH - 1 - Respiration mode: IPPV, Manual
  • TH - 1 - Tidal volume: 50~1500ml
  • TH - 1 - Monitor Parameters: Tidal volume; Minute Ventilation; Breath Frequency; Airway Pressure

Options & accessories

  • TH - 1
  • TH - 1A

Buyer decision support

H902-C manual veterinary anaesthesia machine procurement decision notes

The H902-C is the HQS veterinary anaesthesia machine for clinics that want gas anaesthesia without mains power: the main unit is manually operated, needs no electricity and weighs 2 kg without vaporizer, with a carrying handle. It takes two gas sources, oxygen and nitrous oxide, at 0.25–0.65 MPa through a two-tube O2/N2O flowmeter scaled 0–10 L/min with a linkage device that keeps the O2 concentration at no less than 25%, and has an oxygen flush of more than 25 L/min. It is listed for 2–100 kg animals with closed, semi-closed and semi-open circuits, a CO2 circle absorber with one canister, an APL valve of 0.5–6 kPa and three gauges (O2, N2O and airway pressure). Breathing is manual: tidal volume 20–1500 ml, with rate and I:E set by the clinician. Halothane, enflurane, isoflurane or sevoflurane vaporizers can be chosen, in three small and four big vaporizer types. If you need mechanical ventilation, the TH-1 (IPPV and manual, 1–90 bpm, 50–1500 ml, LED display) and TH-1A (IPPV, SIMV and manual, 1–65 bpm, 50–1600 ml, 5.5-inch screen with P-t and V-t waveforms) ventilators are listed as options; compare with the H1200 series if you want a ventilator in the standard configuration.

Decision factorPublished for this modelConfirm before order
Patients and circuits2–100 kg animals; closed, semi-closed and semi-open; manual breathing, tidal volume 20–1500 ml; rate and I:E set by the clinician; APL valve 0.5–6 kPaTell us your smallest and largest patients, so we can confirm the breathing circuit and bag sizes to include.
Gas supplyO2 and N2O, 0.25–0.65 MPa; two-tube flowmeter 0–10 L/min with linkage device keeping O2 at no less than 25%; O2 flush more than 25 L/min; three gauges (O2, N2O, airway pressure)Say whether you will use N2O at all and give your cylinder or pipeline connector standard.
VaporizerHalothane, enflurane, isoflurane or sevoflurane; 3 small and 4 big vaporizer types to choose fromChoose the agent and vaporizer size you want quoted.
Main unitManual operation, no electricity needed; 2 kg without vaporizer; dedicated handle; CO2 circle absorber with 1 canister; 60 cmH2O peak pressureAsk for the packed size and weight with the vaporizer you choose.
Optional ventilatorsTH-1: gas-driven, electronically controlled, IPPV and manual, 1–90 bpm, I:E 4:1 to 1:6, 50–1500 ml, LED display. TH-1A: IPPV, SIMV and manual, 1–65 bpm, I:E 8:1 to 1:8, 50–1600 ml, 5.5-inch screen, P-t and V-t waveformsIf you need mechanical ventilation, say which ventilator to add; it needs O2 or air as drive gas.
Operating environmentOperation 18–36 °C, humidity 45–75%, 0.95–1.05 bar; storage −20 to 55 °C, humidity ≤93%Tell us if the machine will be used outside these temperature or humidity ranges.

Prepared by HQS Medical Product Team · Documentation reviewed:

Source: H902-C Anesthesia Machine model brochure. Verify the final configuration, documents and destination-market requirements in the quotation and supplied manual.

Warranty and after-sales service for H902-C

How HQS handles warranty, spare parts and repairs for this model.

Warranty period
The main-unit warranty varies by model and order. The period that applies is stated in your quotation and order confirmation; please confirm it before purchase.
What is covered
A malfunction caused by a manufacturing or quality defect within the warranty period is repaired free of charge. Consumables and accessories, damage from misuse, and units with an altered or removed serial label are not covered by the main-unit warranty.
Spare parts
Spare parts and technical support are available for at least eight years from the date HQS ships the product.
Response time
Service requests get a first reply within one business day. Please send the serial number, model, main-unit version and a description of the problem.
Repairs in warranty
If a confirmed warranty fault needs a replacement part, HQS ships the part at its own expense, and the faulty part is returned to HQS.
Repairs after warranty
HQS sends a cost-based quotation and proforma invoice first. Repaired parts are tested before they are returned. Technical help by email or phone is free.

Full warranty and service terms →