HQS Vetcare delivers a high-precision veterinary anesthesia equipment system suitable for animal hospitals, pet clinics, and animal laboratories. This anesthesia machine meets the needs of general anesthesia and medical research for various animals, including mice, dogs, cats, rabbits, monkeys, pigs, and sheep.

Key Features of H1200-1

  • Application 0.5 - 100kg animal
  • Ventilation mode Closed, half - closed, half - open
  • Tidal volume 10 - 2000ml
  • Vaporizer Choose one from Isoflurane, Sevoflurane, Halothane
  • Oxygen source pressure 0.25~0.65Mpa
  • Airway pressure scope 030~60CMH2O
  • Flow Control 0 - 4L/min
  • Oxygen Flush 35L/min~75L/min
  • Pop adjust scope Directs the waste anesthetic gas from the machine to a scavenging system. In the completely open position, the pop - off valve will release pressure at 2 cm H2O, while maintain a constant passive volume in the breathing bags.
  • Inspiration impedance ≦ 0.6Kpa
  • Expiration impedance ≦ 0.6Kpa
  • Absorption tank capacity 700ml
  • Monitoring Airway pressure, Gas source pressure monitoring
  • I:E As doctor need
  • BPM As doctor need
  • Pneumatically driven and electrically controlled
  • Display: LCD digital display
  • Animal Bellow : Big animal : 300 - 1500ML ; Small animal : 0 - 300ML
  • Monitoring : Tidal volume, breathing rate, I:E ratio, p eak airway pressure
  • TV: 0 - 300 , 300 - 1600ml
  • Breathing rate: 2~150bpm
  • I:E ratio: Adjustable 3:1,2:1,1.5:1,1:1,1:1.5,1:2,1:3
  • Upper airway pressure:2~6kpa
  • Lower airway pressure:0.6~2kpa
  • Build in battery : work time more than 1 hour in case of power failure
  • Alarm: Battery low, Power failure, Airway pressure high/low
  • Alarm Silence : Manuel/Auto Switch
  • PIP scope : 5 - 60kpa
  • Display: 9 - inch TFT touch screen
  • Drive gas: Gas type: O2 or Air
  • Inlet pressure: 280 - 600 kPa
  • Max flow : ≤ 120 L/min
  • Operating m ode : VCV, PCV, SPONT, Manual, Demo
  • Waveform: Pressure, Flow - rate, Volume Loop: PV loop, PF loop, FV loop
  • Safety p ressure: System pressure does not exceed 6 KPa
  • Battery t ype: Li - ion, work time more than 2 hours
  • Tidal volume: 20 - 1500ml; Increment: 1 ml
  • Respiratory rate: 1 ~ 100 bpm
  • Inspiratory time: 0.1 ~ 10s
  • Respiratory ratio: 9.9:1 to 1:9.9
  • Percentage of inspiratory pause: 0 to 50%
  • PEEP: OFF, 3 ~ 20 cmH2O
  • Pressure Support: 0 ~ 60 cmH2O
  • Pressure Control: 5 ~ 60 cmH2O
  • Flow trigger : 0.5 ~ 20L/min
  • Pressure Trigger Range: - 1 ~ - 20 cmH2O
  • PSV Insp Termination Level : 25%